Low radiation and low-contrast dose pulmonary CT angiography: Comparison of 80 kVp/60 ml and 100 kVp/80 ml protocols

被引:45
|
作者
Viteri-Ramirez, G. [1 ]
Garcia-Lallana, A. [1 ]
Simon-Yarza, I. [1 ]
Broncano, J. [1 ]
Ferreira, M. [1 ]
Pueyo, J. C. [1 ]
Villanueva, A. [1 ]
Bastarrika, G. [1 ]
机构
[1] Univ Navarra Clin, Serv Radiol, Pamplona 31008, Spain
关键词
COMPUTED-TOMOGRAPHY ANGIOGRAPHY; IMAGE QUALITY; IONIZING-RADIATION; MULTIDETECTOR CT; PATIENT WEIGHT; ABDOMINAL CT; BODY-WEIGHT; EMBOLISM; EXPOSURE; ENHANCEMENT;
D O I
10.1016/j.crad.2011.11.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To determine the image quality and diagnostic performance of an optimized pulmonary computed tomography angiography (CTA) protocol in terms of radiation and contrast volume saving. MATERIALS AND METHODS: Seventy consecutive patients weighting <= 80 kg with clinical suspicion of pulmonary embolism (PE) were prospectively enrolled. Two pulmonary CTA protocols (group A: n = 35, 80 kV/60 ml; group B: n = 35, 100 kV/80 ml) were compared. The presence of PE, image quality parameters [contrast attenuation, contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR)] and effective radiation dose (mSv) were assessed. RESULTS: PE was found in 11 patients (five of group A, six of group B). The total mean attenuation of the pulmonary arteries was significantly higher in group A (362.4 +/- 100.2 HU) than in group B (262.4 +/- 134.3 HU), whereas the CNR and SNR did not differ statistically (14.8 +/- 7.4 and 16.3 +/- 7.5 for group A and 12.5 +/- 8.6 and 13.8 +/- 9.1 for group B, respectively). The estimated effective radiation dose was significantly lower in group A (1.1 +/- 0.7 mSv) than in group B (2.7 +/- 1.2 mSv). CONCLUSION: In individuals weighting <= 80 kg, the evaluated pulmonary CTA protocol allows similar image quality to be achieved as compared with the conventional pulmonary CIA protocol while reducing radiation exposure by 60% and contrast media volume by 25%. (C) 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:833 / 839
页数:7
相关论文
共 50 条
  • [1] Low-dose abdominal CT protocols with a tube voltage setting of 100 kVp or 80 kVp: Performance of radiation dose reduction and influence on visual contrast
    Nakaura, T.
    Kidoh, M.
    Nakamura, S.
    Doi, Y.
    Shiraishi, S.
    Awai, K.
    Harada, K.
    Yamashita, Y.
    CLINICAL RADIOLOGY, 2014, 69 (08) : 804 - 811
  • [2] Radiation Dose Reduction in Cardiac CT Angiography by Applying a Low Tube Voltage: A Comparison Among 120, 100 and 80 kVp Protocols
    Alani, Anas
    CURRENT MEDICAL IMAGING, 2015, 11 (03) : 192 - 199
  • [3] High-Pitch Coronary CT Angiography at 70 kVp With Low Contrast Medium Volume Comparison of 80 and 100 kVp High-Pitch Protocols
    Zhang, Long Jiang
    Qi, Li
    De Cecco, Carlo N.
    Zhou, Chang Sheng
    Spearman, James V.
    Schoepf, U. Joseph
    Lu, Guang Ming
    MEDICINE, 2014, 93 (22)
  • [4] Detection of Pulmonary Emboli With CT Angiography at Reduced Radiation Exposure and Contrast Material Volume Comparison of 80 kVp and 120 kVp Protocols in a Matched Cohort
    Szucs-Farkas, Zsolt
    Schaller, Claudio
    Bensler, Susanne
    Patak, Michael A.
    Vock, Peter
    Schindera, Sebastian T.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (12) : 793 - 799
  • [5] Patient Exposure and Image Quality of Low-Dose Pulmonary Computed Tomography Angiography Comparison of 100-and 80-kVp Protocols
    Szucs-Farkas, Zsolt
    Kurmann, Luzia
    Strautz, Tamara
    Patak, Michael A.
    Vock, Peter
    Schindera, Sebastian T.
    INVESTIGATIVE RADIOLOGY, 2008, 43 (12) : 871 - 876
  • [6] Diagnostic Accuracy of Pulmonary CT Angiography at Low Tube Voltage: Intraindividual Comparison of a Normal-Dose Protocol at 120 kVp and a Low-Dose Protocol at 80 kVp Using Reduced Amount of Contrast Medium in a Simulation Study
    Szucs-Farkas, Zsolt
    Schibler, Fabian
    Cullmann, Jennifer
    Torrente, Jaled Charimo
    Patak, Michael A.
    Raible, Stephan
    Hoppe, Hanno
    Wyttenbach, Rolf
    Vock, Peter
    Schindera, Sebastian T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (05) : W852 - W859
  • [7] High-pitch computed tomography pulmonary angiography with iterative reconstruction at 80 kVp and 20 mL contrast agent volume
    Lu, Guang Ming
    Luo, Song
    Meinel, Felix G.
    McQuiston, Andrew D.
    Zhou, Chang Sheng
    Kong, Xiang
    Zhao, Yan E.
    Zheng, Ling
    Schoepf, U. Joseph
    Zhang, Long Jiang
    EUROPEAN RADIOLOGY, 2014, 24 (12) : 3260 - 3268
  • [8] High-pitch computed tomography pulmonary angiography with iterative reconstruction at 80 kVp and 20 mL contrast agent volume
    Guang Ming Lu
    Song Luo
    Felix G. Meinel
    Andrew D. McQuiston
    Chang Sheng Zhou
    Xiang Kong
    Yan E. Zhao
    Ling Zheng
    U. Joseph Schoepf
    Long Jiang Zhang
    European Radiology, 2014, 24 : 3260 - 3268
  • [9] Prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp with 30 mL contrast agent: An intraindividual comparison with sequential scanning at 120 kVp with 60 mL contrast agent
    Wang, Wei
    Zhao, Yan E.
    Qi, Li
    Li, Xie
    Zhou, Chang Sheng
    Zhang, Long Jiang
    Lu, Guang Ming
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 90 : 97 - 105
  • [10] Achieving low radiation dose and contrast agents dose in coronary CT angiography at 60-kVp ultra-low tube voltage
    He, Weiling
    Huang, Feng
    Wu, Xi
    Xie, An
    Sun, Wenjie
    Liu, Peng
    Hu, Rui
    BMC MEDICAL IMAGING, 2025, 25 (01):