Manufacture of Lead-Specific Screen-Printed Sensor Based on Lead Schiff Base Complex as Carrier and Multi-Walled Carbon Nanotubes for Detection of Pb(II) in Contaminated Water Tests

被引:14
作者
Ali, Tamer Awad [1 ]
Hassan, Abeer M. E. [2 ]
Mohamed, Gehad G. [3 ]
机构
[1] EPRI, Cairo 11727, Egypt
[2] October 6 Univ, Dept Analyt Chem, Fac Pharm, Giza, Egypt
[3] Cairo Univ, Dept Chem, Fac Sci, Giza 12613, Egypt
关键词
Screen-printed electrodes; Schiff base; Pb(II)-Schiff base complex; Real water samples; ION-SELECTIVE ELECTRODES; ENVIRONMENTAL POLLUTED SAMPLES; ATOMIC EMISSION-SPECTROMETRY; REDUCED GRAPHENE OXIDE; POTENTIOMETRIC DETERMINATION; PASTE ELECTRODES; CETYLTRIMETHYLAMMONIUM BROMIDE; GOLD-NANOPARTICLES; DRINKING-WATER; HEAVY-METALS;
D O I
10.20964/2016.12.30
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel screen-printed electrode (SPE) based on [Pb(L)] complex (H2L = 2-((2-(2-(2-(2-hydroxy-5-methoxybenzylidene amino)phenyl)disufanyl)phenylimino) methyl)-4-methoxyphenol) was prepared for selective determination of Pb(II)ion. The ligand and its Pb(II) complex were prepared and characterized using elemental analysis, spectroscopic OR and H-1 NMR) and molar conductance. Different individual variables were optimized using IUPAC recommendation such as graphite powder, plasticizer, amounts of [Pb(L)] complex ionophore and multi-walled carbon nanotubes (MWCNT). Their possible interactions were investigated. In this potentiometric method, fabrication of screen printed (SPE; electrode V) and multi-walled carbon nanotubes-screen-printed (MWCNT-SPE; electrode IX) sensors was described. [Pb(L)] complex alone or with MWCNT was used as modifier in case of electrodes V and IX, respectively. Optimum composition resulted in enhancement in the sensitivity and selectivity of the SPE toward Pb(II)ions significantly over the concentration range of 1.0 x 10(-7)-1.0 x 10(-1) and 4.6 x 10(-8)-1.0 x 10(-1) mol L-1 of Pb(II)with detection limit of 1.0 x 10(-7) and 4.6 X 10(-8) mol L-1 and a Nernstian slope of 28.98 +/- 0.92 and 30.28 +/- 0.70 mV decade(-1) for electrodes V and IX, respectively. No significant change in response was observed over the pH range of 3.0-8.0 and 2.5-8.5 with response time lower than 9 and 7s for electrodes V and IX, respectively. The potentiometric selectivity coefficients were calculated and the results obtained showed the good selectivity of the modified SPE electrodes (V and IX) for Pb(II) ion over other metal ions. Finally, these electrodes were precisely applied for the determination of Pb(II) ions in real spiked water samples. The results obtained using both the proposed potentiometric method and atomic absorption spectrometer (AAS) showed satisfactory agreement.
引用
收藏
页码:10732 / 10747
页数:16
相关论文
共 61 条
[1]  
Abdel-Shafy HI, 2013, EGYPT J CHEM, V56, P449
[2]   Novel ion imprinted polymer magnetic mesoporous silica nano-particles for selective separation and determination of lead ions in food samples [J].
Aboufazeli, Forouzan ;
Zhad, Hamid Reza Lotfi Zadeh ;
Sadeghi, Omid ;
Karimi, Mohammad ;
Najafi, Ezzatollah .
FOOD CHEMISTRY, 2013, 141 (04) :3459-3465
[3]   A Novel Potentiometric Sensor Based on 1,2-Bis(N′-benzoylthioureido)benzene and Reduced Graphene Oxide for Determination of Lead (II) Cation in Raw Milk [J].
Abraham, Abigail Asha ;
Rezayi, Majid ;
Manan, Ninie S. A. ;
Narimani, Leila ;
Bin Rosli, Ahmad Nazmi ;
Alias, Yatimah .
ELECTROCHIMICA ACTA, 2015, 165 :221-231
[4]   Improvement in the performance of a Pb2+ selective potentiometric sensor using modified core/shell SiO2/Fe3O4 nano-structure [J].
Afkhami, Abbas ;
Shirzadmehr, Ali ;
Madrakian, Tayyebeh ;
Bagheri, Hasan .
JOURNAL OF MOLECULAR LIQUIDS, 2014, 199 :108-114
[5]   Construction and Performance Characteristics of Modified Screen Printed and Modified Carbon Paste Sensors for Selective Determination of Cu(II) Ion in Different Polluted Water Samples [J].
Ali, Tamer Awad ;
Mohamed, Gehad G. ;
Said, Amal H. .
CHEMICAL ENGINEERING COMMUNICATIONS, 2016, 203 (06) :724-735
[6]  
Ali TA, 2015, INT J ELECTROCHEM SC, V10, P7275
[7]  
Ali TA, 2015, ANAL METHODS-UK, V7, P6280, DOI [10.1039/c5ay01086a, 10.1039/C5AY01086A]
[8]  
Ali TA, 2015, INT J ELECTROCHEM SC, V10, P4820
[9]   Potentiometric determination of La(III) in polluted water samples using modified screen-printed electrode by self-assembled mercapto compound on silver nanoparticles [J].
Ali, Tamer Awad ;
Mohamed, Gehad G. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 216 :542-550
[10]  
Ali TA, 2015, INT J ELECTROCHEM SC, V10, P2439