Effect of Experimental Design on the Prediction Performance of Calibration Models Based on Near-Infrared Spectroscopy for Pharmaceutical Applications

被引:36
|
作者
Bondi, Robert W., Jr. [1 ]
Igne, Benoit [2 ]
Drennen, James K., III [1 ,2 ]
Anderson, Carl A.
机构
[1] Duquesne Univ, Grad Sch Pharmaceut Sci, Pittsburgh, PA 15282 USA
[2] Duquesne Univ, Ctr Pharmaceut Technol, Sch Pharm, Pittsburgh, PA 15282 USA
关键词
Experimental design; Multivariate calibration; Pharmaceutical; Near-infrared spectroscopy; ANALYTICAL TECHNOLOGY APPROACH; NIR SPECTROSCOPY; SELECTION; SPECTRA;
D O I
10.1366/12-06689
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Near-infrared spectroscopy (NIRS) is a valuable tool in the pharmaceutical industry, presenting opportunities for online analyses to achieve real-time assessment of intermediates and finished dosage forms. The purpose of this work was to investigate the effect of experimental designs on prediction performance of quantitative models based on NIRS using a five-component formulation as a model system. The following experimental designs were evaluated: five-level, full factorial (5-L FF); three-level, full factorial (3-L FF); central composite; I-optimal; and D-optimal. The factors for all designs were acetaminophen content and the ratio of microcrystalline cellulose to lactose monohydrate. Other constituents included croscarmellose sodium and magnesium stearate (content remained constant). Partial least squares-based models were generated using data from individual experimental designs that related acetaminophen content to spectral data. The effect of each experimental design was evaluated by determining the statistical significance of the difference in bias and standard error of the prediction for that model's prediction performance. The calibration model derived from the I-optimal design had similar prediction performance as did the model derived from the 5-L FF design, despite containing 16 fewer design points. It also outperformed all other models estimated from designs with similar or fewer numbers of samples. This suggested that experimental-design selection for calibration-model development is critical, and optimum performance can be achieved with efficient experimental designs (i.e., optimal designs).
引用
收藏
页码:1442 / 1453
页数:12
相关论文
共 50 条
  • [1] Pharmaceutical Applications of Near-Infrared Spectroscopy
    Muselik, Jan
    CHEMICKE LISTY, 2012, 106 (01): : 10 - 15
  • [2] Near-infrared spectroscopy applications in pharmaceutical analysis
    Luypaert, J.
    Massart, D. L.
    Heyden, Y. Vander
    TALANTA, 2007, 72 (03) : 865 - 883
  • [3] Comparison of calibration models for rapid prediction of lignin content in lignocellulosic biomass based on infrared and near-infrared spectroscopy
    Herdlevaer, Kristoffer Mega
    Lohre, Camilla
    Nodland, Egil
    Barth, Tanja
    RESULTS IN CHEMISTRY, 2022, 4
  • [4] Calibration models for determination of water content in pharmaceutical excipients using near-infrared spectroscopy (NIRS)
    Beyer, J
    Steffens, KJ
    PHARMAZEUTISCHE INDUSTRIE, 2003, 65 (02): : 186 - 192
  • [5] Near-infrared spectroscopy and imaging: Basic principles and pharmaceutical applications
    Reich, G
    ADVANCED DRUG DELIVERY REVIEWS, 2005, 57 (08) : 1109 - 1143
  • [6] Operationalizing Maintenance of Calibration Models Based on Near-Infrared Spectroscopy by Knowledge Integration
    Miyano, Takuya
    Nakagawa, Hiroshi
    Watanabe, Tomoyuki
    Minami, Hidemi
    Sugiyama, Hirokazu
    JOURNAL OF PHARMACEUTICAL INNOVATION, 2015, 10 (04) : 287 - 301
  • [7] Operationalizing Maintenance of Calibration Models Based on Near-Infrared Spectroscopy by Knowledge Integration
    Takuya Miyano
    Hiroshi Nakagawa
    Tomoyuki Watanabe
    Hidemi Minami
    Hirokazu Sugiyama
    Journal of Pharmaceutical Innovation, 2015, 10 : 287 - 301
  • [8] Application of Model-based Experimental Design for the Calibration of Online Composition Measurement by Near-infrared Spectroscopy
    Hasskerl, Daniel
    Market, Steven
    Engell, S.
    2016 24TH MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION (MED), 2016, : 967 - 972
  • [9] Effects and Detection of Raw Material Variability on the Performance of Near-Infrared Calibration Models for Pharmaceutical Products
    Igne, Benoit
    Shi, Zhenqi
    Drennen, James K., III
    Anderson, Carl A.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2014, 103 (02) : 545 - 556
  • [10] Experimental Design, Near-Infrared Spectroscopy, and Multivariate Calibration: An Advanced Project in a Chemometrics Course
    de Oliveira, Rodrigo R.
    das Neves, Luiz S.
    de Lima, Kassio M. G.
    JOURNAL OF CHEMICAL EDUCATION, 2012, 89 (12) : 1566 - 1571