Interturn Fault Diagnosis for Model-Predictive-Controlled-PMSM Based on Cost Function and Wavelet Transform

被引:119
作者
Hang, Jun [1 ,2 ]
Zhang, Jibo [1 ,2 ]
Xia, Mengjie [1 ,2 ]
Ding, Shichuan [1 ,2 ]
Hua, Wei [3 ]
机构
[1] Anhui Univ, Sch Elect Engn & Automat, Hefei 230601, Peoples R China
[2] Anhui Univ, Natl Engn Lab Energy Saving Motor & Control Tech, Hefei 230601, Peoples R China
[3] Southeast Univ, Sch Elect Engn, Nanjing 210096, Peoples R China
基金
中国国家自然科学基金;
关键词
Cost function; fault diagnosis; interturn fault (ITF); model predictive control (MPC); permanent magnet synchronous machine (PMSM); wavelet transform; MAGNET SYNCHRONOUS MOTOR; NONSTATIONARY CONDITIONS; MACHINES; DRIVE; TORQUE; SCHEME;
D O I
10.1109/TPEL.2019.2953269
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Interturn fault (ITF) is a common fault for permanent magnet synchronous machine (PMSM). If the ITF is not detected in time, its propagation may result in the secondary damage, even the damage to the whole electrical machine. Recently, model predictive control (MPC) has been widely studied for the PMSM drive system because of its simple structure and excellent dynamic performance. However, the previous ITF diagnosis methods are mainly focused on vector control and direct toque control systems, and few research works are specifically focused on ITF diagnosis for the model-predictive-controlled-PMSM. Hence, to fill this gap and improve the reliability of the model-predictive-controlled-PMSM, this article first proposes an ITF diagnosis method for the model-predictive-controlled-PMSM, taking into account the characteristics of the MPC system. In this method, wavelet transformis applied to extract the fault feature from the cost function existing in the MPC system, and the ITF is diagnosed by monitoring the normalized energy-related feature vector calculated from the wavelet transform coefficients. Additionally, to further show the performance of the proposed method, the popular diagnosis methods based on the stator current and zero sequence voltage component are studied for the comparative analysis. Both the simulation and experimental results verify the effectiveness of the proposed fault diagnosis method.
引用
收藏
页码:6405 / 6418
页数:14
相关论文
共 42 条
[21]   Investigations on mother wavelet selection for health assessment of lathe bearings [J].
Kulkarni, P. G. ;
Sahasrabudhe, A. D. .
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2017, 90 (9-12) :3317-3331
[22]   Real-Time Detection of Interturn Faults in PM Drives Using Back-EMF Estimation and Residual Analysis [J].
Leboeuf, Nicolas ;
Boileau, Thierry ;
Nahid-Mobarakeh, Babak ;
Clerc, Guy ;
Meibody-Tabar, Farid .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2011, 47 (06) :2402-2412
[23]   Model Predictive Control of a Two-Motor Drive With Five-Leg-Inverter Supply [J].
Lim, Chee Shen ;
Abd Rahim, Nasrudin ;
Hew, Wooi Ping ;
Levi, Emil .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (01) :54-65
[24]   A Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM [J].
Mazzoletti, Manuel A. ;
Bossio, Guillermo R. ;
De Angelo, Cristian H. ;
Espinoza-Trejo, Diego R. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (09) :7218-7228
[25]   Interturn Short Fault Diagnosis in a PMSM by Voltage and Current Residual Analysis With the Faulty Winding Model [J].
Moon, Seokbae ;
Jeong, Hyeyun ;
Lee, Hojin ;
Kim, Sang Woo .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2018, 33 (01) :190-198
[26]   ANN based fault diagnosis of permanent magnet synchronous motor under stator winding shorted turn [J].
Moosavi, S. S. ;
Djerdir, A. ;
Ait-Amirat, Y. ;
Khaburi, D. A. .
ELECTRIC POWER SYSTEMS RESEARCH, 2015, 125 :67-82
[27]   A Comparative Study of Predictive Current Control Schemes for a Permanent-Magnet Synchronous Machine Drive [J].
Morel, Florent ;
Lin-Shi, Xuefang ;
Retif, Jean-Marie ;
Allard, Bruno ;
Buttay, Cyril .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (07) :2715-2728
[28]   Application of Artificial Intelligence to Real-Time Fault Detection in Permanent-Magnet Synchronous Machines [J].
Nyanteh, Yaw ;
Edrington, Chris ;
Srivastava, Sanjeev ;
Cartes, David .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (03) :1205-1214
[29]   Early Intermittent Interturn Fault Detection and Localization for a Permanent Magnet Synchronous Motor of Electrical Vehicles Using Wavelet Transform [J].
Obeid, Najla Haje ;
Battiston, Alexandre ;
Boileau, Thierry ;
Nahid-Mobarakeh, Babak .
IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2017, 3 (03) :694-702
[30]   Induction Motor Diagnosis Based on a Transient Current Analytic Wavelet Transform via Frequency B-Splines [J].
Pons-Llinares, Joan ;
Antonino-Daviu, Jose A. ;
Riera-Guasp, Martin ;
Pineda-Sanchez, Manuel ;
Climente-Alarcon, Vicente .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (05) :1530-1544