Bioelectrical Impedance Analysis in the Assessment of Hydration Status in Peritoneal Dialysis Patients

被引:0
|
作者
Haapio, Mikko [1 ,2 ]
Lentini, Paolo [2 ,3 ]
House, Andrew A. [2 ,4 ]
de Cal, Massimo [2 ]
Cruz, Dinna N. [2 ]
Gong, Dehua [2 ]
Rodighiero, Maria Pia [2 ]
Dell'Aquila, Roberto [2 ,3 ]
Ronco, Claudio [2 ]
机构
[1] Univ Helsinki, Cent Hosp, Div Nephrol, FI-00029 Helsinki, Finland
[2] San Bortolo Hosp, Dept Nephrol, Int Renal Res Inst IRRIV, Vicenza, Italy
[3] San Bortolo Hosp, Dept Nephrol, Bassano Del Grappa, Italy
[4] London Hlth Sci Ctr, Div Nephrol, London, ON, Canada
关键词
BRAIN NATRIURETIC PEPTIDE; RESIDUAL RENAL-FUNCTION; LEFT-VENTRICULAR DYSFUNCTION; BODY-COMPOSITION; BLOOD-PRESSURE; VOLUME STATUS; EXTRACELLULAR WATER; VECTOR DISTRIBUTION; FLUID STATUS; NT-PROBNP;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective: Assessment of fluid status in chronic peritoneal dialysis (PD) patients is complex. Clinical evaluation based solely on body weight, blood pressure, volume of ultrafiltration (UF) and peripheral edema is insufficient. A non-invasive test, bioelectrical impedance analysis (BIA) might be of potential benefit. Aim: To test whether BIA correlates with other ancillary markers of extracellular fluid volume, namely B-type natriuretic peptide (BNP), residual renal function (RRF) and UF, and whether BIA provides complementary information in categorizing PD patients vis-a-vis hydration status. Methods: A cross-sectional study of 61 out-patients on chronic PD. Single-frequency BIA measurements of resistance/height were divided into tertiles (lowest: <253 Omega/m; middle: >= 253 Omega/m and <316 Omega/m; highest: >= 316 Omega/m). Results: Compared to patients in the highest tertile of BIA (least fluid), patients in the lowest tertile (most fluid) had highest BNP, RRF and UF (93.5 vs. 55.0 pg/ml, p = 0.029; 850 vs. 300 ml/day, p = 0.05; and 1.75 vs. 1.21 l/day, p = 0.023, respectively). Conclusions: BIA tertiles categorized PD patients who differed in BNP, RRF and UF in a stepwise pattern, suggesting BIA may better inform hydration status, and serve as an additional clinical tool in management of chronic PD patients. Copyright (c) 2012 S. Karger AG, Basel
引用
收藏
页码:238 / 245
页数:8
相关论文
共 50 条
  • [21] BIOELECTRICAL-IMPEDANCE ANALYSIS - A PROMISING PREDICTIVE TOOL FOR NUTRITIONAL ASSESSMENT IN CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS PATIENTS
    SCHMIDT, RJ
    DUMLER, F
    PERITONEAL DIALYSIS INTERNATIONAL, 1993, 13 (04): : 250 - 255
  • [22] Accuracy of eight-polar bioelectrical impedance analysis for the assessment of total and appendicular body composition in peritoneal dialysis patients
    G Medici
    C Mussi
    A L Fantuzzi
    M Malavolti
    A Albertazzi
    G Bedogni
    European Journal of Clinical Nutrition, 2005, 59 : 932 - 937
  • [23] Detection of hydration status by total body bioelectrical impedance analysis (BIA) in patients on hemodialysis
    Oe, B
    DeFijter, WM
    DeFijter, CWH
    Straver, B
    Oe, PL
    Stevens, F
    DeVries, PMJM
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (07): : 371 - 374
  • [24] Bioelectrical impedance analysis (BIA) phase angle (PhA) predicts nutritional status and survival in peritoneal dialysis (PD) patients (pts).
    Fein, PA
    Gadh, R
    Mittman, N
    Gundumalla, G
    Matza, B
    Chattopadhyay, J
    Avram, MM
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 : 205A - 205A
  • [25] Bioelectrical impedance to estimate changes in hydration status
    O'Brien, C
    Young, AJ
    Sawka, MN
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2002, 23 (05) : 361 - 366
  • [26] Assessment of haematocrit status using bioelectrical impedance analysis in dengue patients
    Ibrahim, F
    Ismail, NA
    Taib, MN
    Abu Bakar, W
    Abas, W
    Sulaiman, S
    Guan, CC
    MODELLING AND CONTROL IN BIOMEDICAL SYSTEMS 2003 (INCLUDING BIOLOGICAL SYSTEMS), 2003, : 277 - 281
  • [27] Evaluating hyponatremia by bioelectrical impedance in uremic patients on continuous ambulatory peritoneal dialysis
    Lin, SH
    Chu, PL
    Cheng, CJ
    Chen, CC
    Lin, YF
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2005, 20 : V345 - V345
  • [28] The value of bioimpedance analysis in the assessment of hydration and nutritional status in children on chronic peritoneal dialysis
    Yuan, Wei
    Yu, Minghui
    Zhang, Zhiqing
    Miao, Qianfan
    Liu, Jiaojiao
    Zhang, Hui
    Zhou, Qing
    Chen, Jing
    Zhai, Yihui
    Fang, Xiaoyan
    Xu, Hong
    Shen, Qian
    RENAL FAILURE, 2024, 46 (01)
  • [29] Making the choice between bioelectrical impedance measures for body hydration status assessment
    Davydov, Dmitry M.
    Boev, Andrey
    Gorbunov, Stas
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [30] Making the choice between bioelectrical impedance measures for body hydration status assessment
    Dmitry M. Davydov
    Andrey Boev
    Stas Gorbunov
    Scientific Reports, 11