Robotically assisted long bone biopsy under MRI: cadaver study results

被引:6
|
作者
Lim, Sunghwan [1 ]
Sharma, Karun [2 ]
Li, Pan [1 ]
Petrisor, Doru [1 ]
Fricke, Stanley [2 ]
Stoianovici, Dan [1 ]
Cleary, Kevin [2 ]
机构
[1] Johns Hopkins Univ, Robot Lab, Brady Urol Inst, Baltimore, MD USA
[2] Childrens Natl Hlth Syst, Sheikh Zayed Inst Pediat Surg Innovat, 111 Michigan Ave, Washington, DC 20010 USA
基金
美国国家卫生研究院;
关键词
MRI; Long bone biopsy; MR-safe; Robot; Cadaver; SAFE ROBOT; SYSTEMS;
D O I
10.1007/s11548-018-1889-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Rationale and objectives We have designed and constructed an MR-safe robot made entirely of nonmetallic components with pneumatic actuators and optical encoders. The robot was developed to enable bone biopsies to be performed under magnetic resonance imaging (MRI) guidance in pediatric patients. The purpose of this study was to show the feasibility of using the robot for biopsy of the femur and tibia in a cadaver leg. Our long-term goal is to eliminate radiation exposure during bone biopsy procedures and provide more timely and accurate diagnosis for children with bone cancers and bone infections.MethodsThe MR-safe robot was mounted on the MRI table. A cadaver leg was procured from an anatomy supply house and placed on the MRI table. All required hospital precautions for infection control were taken. A total of 10 biopsy targets were sampled using MRI guidance: five from the femur and five from the tibia. A handheld, commercially available battery-powered bone drill was used to facilitate drilling through the cortex. After the study, the leg was scanned with CT to better visualize and document the bone biopsy sites. Both the MRI and CT images were used to analyze the results.ResultsAll of the targets were successfully reached with an average targeting accuracy of 1.43mm. A workflow analysis showed the average time for the first biopsy was 41min including robot setup time and 22min for each additional biopsy including the time for the repeat MRI scan used to confirm accurate targeting. The robot was shown to be MRI transparent, as no image quality degradation due to the use of the robot was detected.ConclusionThe results showed the feasibility of using an MR-safe robotic system to assist the interventional radiologist in performing precision bone biopsy under MRI guidance. Future work will include developing an MR-safe drill, improving the mounting of the robot and fixation of the leg, and moving toward first in child clinical trials.
引用
收藏
页码:147 / 156
页数:10
相关论文
共 10 条
  • [1] Robotically assisted long bone biopsy under MRI: cadaver study results
    Sunghwan Lim
    Karun Sharma
    Pan Li
    Doru Petrisor
    Stanley Fricke
    Dan Stoianovici
    Kevin Cleary
    International Journal of Computer Assisted Radiology and Surgery, 2019, 14 : 147 - 156
  • [2] Robotically Assisted Long Bone Biopsy Under MRI Imaging: Workflow and Preclinical Study
    Cleary, Kevin
    Lim, Sunghwan
    Jun, Changhan
    Monfaredi, Reza
    Sharma, Karun
    Fricke, Stanley Thomas
    Vargas, Luis
    Petrisor, Doru
    Stoianovici, Dan
    ACADEMIC RADIOLOGY, 2018, 25 (01) : 74 - 81
  • [3] A novel pneumatic drill for bone biopsy under MRI imaging
    Fischer, Elizabeth
    Gebremeskel, Mikias
    Stoianovici, Dan
    Sharma, Karun
    Cleary, Kevin
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2024, 19 (03) : 405 - 409
  • [4] Prediction of Bone Marrow Biopsy Results From MRI in Multiple Myeloma Patients Using Deep Learning and Radiomics
    Wennmann, Markus
    Ming, Wenlong
    Bauer, Fabian
    Chmelik, Jiri
    Klein, Andre
    Uhlenbrock, Charlotte
    Groezinger, Martin
    Kahl, Kim-Celine
    Nonnenmacher, Tobias
    Debic, Manuel
    Hielscher, Thomas
    Thierjung, Heidi
    Rotkopf, Lukas T.
    Stanczyk, Nikolas
    Sauer, Sandra
    Jauch, Anna
    Goetz, Michael
    Kurz, Felix T.
    Schlamp, Kai
    Horger, Marius
    Afat, Saif
    Besemer, Britta
    Hoffmann, Martin
    Hoffend, Johannes
    Kraemer, Doris
    Graeven, Ullrich
    Ringelstein, Adrian
    Bonekamp, David
    Kleesiek, Jens
    Floca, Ralf O.
    Hillengass, Jens
    Mai, Elias K.
    Weinhold, Niels
    Weber, Tim F.
    Goldschmidt, Hartmut
    Schlemmer, Heinz-Peter
    Maier-Hein, Klaus
    Delorme, Stefan
    Neher, Peter
    INVESTIGATIVE RADIOLOGY, 2023, 58 (10) : 754 - 765
  • [5] Prospective study of bone marrow infiltration in aggressive lymphoma by three independent methods:: Whole-body MRI, PET/CT and bone marrow biopsy
    Ribrag, Vincent
    Vanel, Daniel
    Leboulleux, Sophie
    Lumbroso, Jean
    Couanet, Dominique
    Bonniaud, Guillaume
    Auperin, Anne
    Masson, Florence
    Bosq, Jacques
    Edeline, Veronique
    Ferme, Christophe
    Pigneur, Frederic
    Schlumberger, Martin
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 66 (02) : 325 - 331
  • [6] Bone marrow involvement in Gaucher disease at MRI : what long-term evolution can we expect under enzyme replacement therapy?
    Fedida, Benjamin
    Touraine, Sebastien
    Stirnemann, Jerome
    Belmatoug, Nadia
    Laredo, Jean-Denis
    Petrover, David
    EUROPEAN RADIOLOGY, 2015, 25 (10) : 2969 - 2975
  • [7] Bone marrow involvement in Gaucher disease at MRI : what long-term evolution can we expect under enzyme replacement therapy?
    Benjamin Fedida
    Sébastien Touraine
    Jerôme Stirnemann
    Nadia Belmatoug
    Jean-Denis Laredo
    David Petrover
    European Radiology, 2015, 25 : 2969 - 2975
  • [8] Do benign-concordant breast MRI biopsy results require short interval follow-up imaging? Report of longitudinal study and review of the literature
    Pinkney, David M.
    Chikarmane, Sona A.
    Giess, Catherine S.
    CLINICAL IMAGING, 2019, 57 : 50 - 55
  • [9] MRI assisted focal boost integrated with HDR monotherapy study in low and intermediate risk prostate cancer (MARS): Results from a phase II clinical trial
    Alayed, Yasir
    D'Alimonte, Laura
    Helou, Joelle
    Ravi, Ananth
    Morton, Gerard
    Chung, Hans T.
    Haider, Masoom
    McGuffin, Merrylee
    Zhang, Liying
    Loblaw, Andrew
    RADIOTHERAPY AND ONCOLOGY, 2019, 141 : 144 - 148
  • [10] Chronic global analysis of vascular permeability and cerebral blood flow after bone marrow stromal cell treatment of traumatic brain injury in the rat: A long-term MRI study
    Li, Lian
    Chopp, Michael
    Ding, Guangliang
    Li, Qingjiang
    Mahmood, Asim
    Jiang, Quan
    BRAIN RESEARCH, 2017, 1675 : 61 - 70