Threshold prediction using the auditory steady-state response and the tone burst auditory brain stem response: A within-subject comparison

被引:57
|
作者
Johnson, TA
Brown, CJ
机构
[1] Univ Iowa, Dept Speech Pathol & Audiol, Iowa City, IA 52242 USA
[2] Univ Iowa Hosp & Clin, Dept Otolaryngol Head & Neck Surg, Iowa City, IA 52242 USA
来源
EAR AND HEARING | 2005年 / 26卷 / 06期
关键词
D O I
10.1097/01.aud.0000188105.75872.a3
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: The purpose of this study was to evaluate the accuracy with which auditory steady-state response (ASSR) and tone burst auditory brain stem response (ABR) thresholds predict behavioral thresholds, using a within-subjects design. Because the spectra of the stimuli used to evoke the ABR and the ASSR differ, it was hypothesized that the predictive accuracy also would differ, particularly in subjects with steeply sloping hearing losses. Design: ASSR and ABR thresholds were recorded in a group of 14 adults with normal hearing, 10 adults with flat, sensorineural hearing losses, and 10 adults with steeply sloping, high-frequency, sensorineural hearing losses. Evoked-potential thresholds were recorded at 1, 1.5, and 2 kHz and were compared with behavioral, pure-tone thresholds. The predictive accuracy of two ABR protocols was evaluated: Blackman-gated tone bursts and lineargated tone bursts presented in a background of notched noise. Two ASSR stimulation protocols also were evaluated: 100% amplitude-modulated (AM) sinusoids and 100% AM plus 25% frequency-modulated (FM) sinusoids. Results: The results suggested there was no difference in the accuracy with which either ABR protocol predicted behavioral threshold, nor was there any difference in the predictive accuracy of the two ASSR protocols. On average, ABR thresholds were recorded 3 dB closer to behavioral threshold than ASSR thresholds. However, in the subjects with the most steeply sloping hearing losses, ABR thresholds were recorded as much as 25 dB below behavioral threshold, whereas ASSR thresholds were never recorded more than 5 dB below behavioral threshold, which may reflect more spread of excitation for the ABR than for the ASSR. In contrast, the ASSR overestimated behavioral threshold in two subjects with normal hearing, where the ABR provided a more accurate prediction of behavioral threshold. Conclusions: Both the ABR and the ASSR provided reasonably accurate predictions of behavioral threshold across the three subject groups. There was no evidence that the predictive accuracy of the ABR evoked using Blackman-gated tone bursts differed from the predictive accuracy observed when linear-gated tone bursts were presented in conjunction with notched noise. Similarly, there was no evidence that the predictive accuracy of the AM ASSR differed from the AM/FM ASSR. In general, ABR thresholds were recorded at levels closer to behavioral threshold than the ASSR. For certain individuals with steeply sloping hearing losses, the ASSR may be a more accurate predictor of behavioral thresholds; however, the ABR may be a more appropriate choice when predicting behavioral thresholds in a population where the incidence of normal hearing is expected to be high.
引用
收藏
页码:559 / 576
页数:18
相关论文
共 50 条
  • [31] Eyes-Closed Brain Computer Interface Using Modulation of Steady-State Visually Evoked Potential and Auditory Steady-State Response
    Nishifuji, Seiji
    Matsubara, Atsushi
    Sugita, Yuya
    Iwata, Akira
    Nakamura, Hirotaka
    Hirano, Hitoshi
    2017 56TH ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS OF JAPAN (SICE), 2017, : 1138 - 1143
  • [32] Comparison of Frequency-Specific Hearing Thresholds between Pure-Tone Audiometry and Auditory Steady-State Response
    Swami, Himanshu
    Kumar, Santosh
    INDIAN JOURNAL OF OTOLOGY, 2019, 25 (02) : 59 - 65
  • [33] CHOLINERGIC MODULATION OF AUDITORY STEADY-STATE RESPONSE IN THE AUDITORY CORTEX OF THE FREELY MOVING RAT
    Zhang, J.
    Ma, L.
    Li, W.
    Yang, P.
    Qin, L.
    NEUROSCIENCE, 2016, 324 : 29 - 39
  • [34] The Auditory Enhancement Effect is Not Reflected in the 80-Hz Auditory Steady-State Response
    Carcagno, Samuele
    Plack, Christopher J.
    Portron, Arthur
    Semal, Catherine
    Demany, Laurent
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2014, 15 (04): : 621 - 630
  • [35] The Auditory Enhancement Effect is Not Reflected in the 80-Hz Auditory Steady-State Response
    Samuele Carcagno
    Christopher J. Plack
    Arthur Portron
    Catherine Semal
    Laurent Demany
    Journal of the Association for Research in Otolaryngology, 2014, 15 : 621 - 630
  • [36] Comparison between auditory steady-state responses and pure-tone audiometry
    Komazec, Zoran
    Lemajic-Komazec, Slobodanka
    Jovic, Rajko
    Nadj, Congor
    Jovancevic, Ljiljana
    Savovic, Slobodan
    VOJNOSANITETSKI PREGLED, 2010, 67 (09) : 761 - 765
  • [37] Attentional modulation of the auditory steady-state response across the cortex
    Manting, Cassia Low
    Andersen, Lau M.
    Gulyas, Balazs
    Ullen, Fredrik
    Lundqvist, Daniel
    NEUROIMAGE, 2020, 217
  • [38] Stimulus Variability Affects the Amplitude of the Auditory Steady-State Response
    Simpson, Michael I. G.
    Woods, William P.
    Prendergast, Garreth
    Johnson, Sam R.
    Green, Gary G. R.
    PLOS ONE, 2012, 7 (04):
  • [39] Spatiotemporal reconstruction of the auditory steady-state response to frequency modulation using magnetoencephalography
    Millman, Rebecca E.
    Prendergast, Garreth
    Kitterick, Padraig T.
    Woods, Will P.
    Green, Gary G. R.
    NEUROIMAGE, 2010, 49 (01) : 745 - 758
  • [40] The effect of stimulus envelope shape on the auditory steady-state response
    Van Canneyt, Jana
    Hofmann, Michael
    Wouters, Jan
    Francart, Tom
    HEARING RESEARCH, 2019, 380 : 22 - 34