Interventional MR-guided excisional biopsy of breast lesions

被引:34
|
作者
Gould, SWT [1 ]
Lamb, G [1 ]
Lomax, D [1 ]
Gedroyc, W [1 ]
Darzi, A [1 ]
机构
[1] St Marys Hosp, NHS Trust, Minimal Access Surg Unit, London W2 1NY, England
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1998年 / 8卷 / 01期
关键词
interventional MR; image-guided surgery; breast lesion;
D O I
10.1002/jmri.1880080110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Interventional MR (IMR) machines have produced unique opportunities for image-guided surgery. The open configuration design and fast pulse sequences allow intraoperative scanning to monitor procedures. This study was undertaken to assess the potential use of IMR for image-guided surgery. Benign breast lesion excision was chosen as an uncomplicated surgical model. Ten female patients with known benign tumors underwent excision biopsy under general anesthesia in a Signs SP10 .5-T IMR machine (General Electric Medical Systems, Milwaukee, WI), Lesions were localized with precontrast and postcontrast (intravenous gadolinium-diethylenetriamine pentaacetic acid,.2 mmol/kg) fast multiplanar spoiled gradient-recalled acquisition in the steady state (GRASS) sequences. Preoperative "real-time" fast gradient-recalled sequences were also obtained using the Flashpoint (General Electric Medical Systems, Milwaukee, WI) tracker device. The maximum dimensions of each lesion were measured from the resulting images. Excision was performed using titanium instruments and an ultrasonically activated scalpel. Intraoperative real-time scanning demonstrated the resection margin and confirmed complete excision. The maximum dimensions of the macroscopic specimens were compared with those from the MR images. All tumors were visualized with the Signa scanner and real-time imaging and the images were enhanced after intravenous contrast. Maximum dimensions on histologic examination were not significantly different from those measured from Signs (P > .17) or real-time images (p > .4). There was no significant difference between lesion size from Signs and real-time images (P > .25). All postprocedure scans demonstrated complete excision. There were six fibroadenomas, two foci of sclerosing adenosis, one area of fibrocystic disease, and one schwannoma, Intraoperative MR scanning reliably identifies palpable breast tumors and can accurately guide surgical excision. Further work using MR guidance can now be performed in other general surgical areas.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 50 条
  • [41] Intraoperative ultrasonographically guided excisional biopsy or vacuum-assisted core needle biopsy for nonpalpable breast lesions
    Chen, SC
    Yang, HR
    Hwang, TL
    Chen, MF
    Cheung, YC
    Hsueh, S
    ANNALS OF SURGERY, 2003, 238 (05) : 738 - 742
  • [42] INDICATIONS AND CLINICAL EFFICACY OF MR-GUIDED BREAST LOCALIZATION OR BIOPSY - PRELIMINARY-RESULTS
    SCHNALL, MD
    OREL, SG
    HOCHMAN, MG
    POWELL, CM
    TOROSIAN, MH
    ROSATO, EF
    RADIOLOGY, 1995, 197 : 129 - 129
  • [43] Ultrasound guided excisional biopsy of non-palpable breast lesions: Technique and preliminary results
    di Giorgio, A
    Arnone, P
    Canavese, A
    EUROPEAN JOURNAL OF SURGERY, 1998, 164 (11) : 819 - 824
  • [44] MR-guided biopsy: A review of current techniques and applications
    Weiss, Clifford R.
    Nour, Sherif Gamal
    Lewin, Jonathan S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (02) : 311 - 325
  • [45] An apparatus for MR-Guided breast lesion localization and core biopsy: Design and preliminary results
    Schneider, E
    Rohling, KW
    Schnall, MD
    Giaquinto, RO
    Morris, EA
    Ballon, D
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) : 243 - 253
  • [46] A novel MR-guided interventional device for 3D circumferential access to breast tissue
    Smith, Matthew
    Zhai, Xu
    Harter, Ray
    Sisney, Gale
    Elezaby, Mai
    Fain, Sean
    MEDICAL PHYSICS, 2008, 35 (08) : 3779 - 3786
  • [47] MR-guided percutaneous core biopsy of small breast lesions: First experience with a vertically open 0.5T scanner
    Schneider, JP
    Schulz, T
    Horn, LC
    Leinung, S
    Schmidt, F
    Kahn, T
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) : 374 - 385
  • [48] A new method of MR-guided mamma biopsy.
    Thiele, J
    Schneider, JP
    Franke, P
    Lieberenz, S
    Schmidt, F
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (04): : 374 - 379
  • [49] MR-guided endomyocardial biopsy in a preclinical in vivo model
    Behm, P.
    Gastl, M.
    Jahn, A.
    Rohde, A.
    Krueger, S.
    Weiss, S.
    Schnackenburg, B.
    Sager, M.
    Duering, K.
    Clogenson, H.
    Horn, P.
    Westenfeld, R.
    Kelm, M.
    Neizel-Wittke, M.
    Boenner, F.
    EUROPEAN HEART JOURNAL, 2017, 38 : 223 - 223
  • [50] Silent active device tracking for MR-guided interventional procedures
    Stehning, Christian
    Krueger, Sascha
    Weiss, Steffen
    Smink, Jouke
    Koken, Peter
    Hindricks, Gerhard
    Jahnke, Cosima
    Paetsch, Ingo
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (05) : 2005 - 2013