Noninvasive assessment of intraventricular pressure difference in left ventricular dyssynchrony using vector flow mapping

被引:4
作者
Minami, Seina [1 ]
Masuda, Kasumi [1 ]
Stugaard, Marie [1 ]
Kamimukai, Toshiki [1 ]
Asanuma, Toshihiko [1 ]
Nakatani, Satoshi [2 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Hlth Sci, Div Funct Diagnost, 1-7 Yamadaoka, Suita, Osaka 5650871, Japan
[2] Saiseikai Senri Hosp, 1-1-6 Tsukumodai, Suita, Osaka 5650862, Japan
基金
日本学术振兴会;
关键词
Vector flow mapping; Diastolic function; Intraventricular pressure difference; Left ventricular dyssynchrony; DIASTOLIC SUCTION; ELASTIC RECOIL; HEART-FAILURE; RELAXATION; GRADIENTS; IMPACT; LINK;
D O I
10.1007/s00380-020-01664-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Diastolic intraventricular pressure difference (IVPD) reflects left ventricular (LV) diastolic function. The relative pressure imaging (RPI) enables the noninvasive quantification of IVPD based on vector flow mapping (VFM) and visualization of regional pressure distribution. LV dyssynchrony causes deterioration of cardiac performance. However, it remains unclear how IVPD is modulated by LV dyssynchrony. LV dyssynchrony was created in ten open-chest dogs by right ventricular (RV) pacing. The other ten dogs undergoing right atrial (RA) pacing set at the similar heart rate with RV pacing were used as controls. Echocardiographic images were acquired at baseline and during pacing simultaneously with LV pressure measurement by a micromanometer. Pressure difference (Delta P) was computed between the apex and the base of the LV inflow tract during a cardiac cycle by RPI and Delta P during isovolumic relaxation time (Delta P-IRT), a parameter of diastolic suction, and that during early filling phase (Delta P-E) were measured. During RV pacing, stroke volume (SV) and Delta P(IRT)decreased significantly, while Delta P(E)did not change compared to the baseline. During RA pacing, SV, Delta P(IRT)and Delta P(E)did not change significantly. Delta P(IRT)tended to correlate with -dP/dt(min)and end-systolic volume, and significantly correlated with ejection fraction. IVPD during isovolumic relaxation time was decreased by LV dyssynchrony, while IVPD during early filling phase was not. A reduction of diastolic suction is observed in LV dyssynchrony and is significantly related to a decrease in SV.
引用
收藏
页码:92 / 98
页数:7
相关论文
共 20 条
[1]   Accuracy and limitations of vector flow mapping: left ventricular phantom validation using stereo particle image velocimetory [J].
Asami R. ;
Tanaka T. ;
Kawabata K.-I. ;
Hashiba K. ;
Okada T. ;
Nishiyama T. .
Journal of Echocardiography, 2017, 15 (2) :57-66
[2]   Relationship between ventricular contractility and early diastolic intraventricular pressure gradients: A diastolic link to systolic function [J].
Firstenberg, Michael S. ;
Greenberg, Neil L. ;
Garcia, Mario J. ;
Thomas, James D. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (05) :501-506
[3]  
Firstenberg MS, 2001, CIRCULATION, V104, pI330
[4]   CRT Improves LV Filling Dynamics Insights From Echocardiographic Particle Imaging Velocimetry [J].
Goliasch, Georg ;
Goscinska-Bis, Kinga ;
Caracciolo, Giuseppe ;
Nakabo, Ayumi ;
Smolka, Grzegorz ;
Pedrizzetti, Gianni ;
Narula, Jagat ;
Sengupta, Partho P. .
JACC-CARDIOVASCULAR IMAGING, 2013, 6 (06) :704-713
[5]   The Impact of Function-Flow Interaction on Left Ventricular Efficiency in Patients with Conduction Abnormalities: A Particle Image Velocimetry and Tissue Doppler Study [J].
Gurel, Emre ;
Prinz, Christian ;
Van Casteren, Lieve ;
Gao, Hang ;
Willems, Rik ;
Voigt, Jens-Uwe .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2016, 29 (05) :431-440
[6]   Intraventricular Flow Velocity Vector Visualization Based on the Continuity Equation and Measurements of Vorticity and Wall Shear Stress [J].
Itatani, Keiichi ;
Okada, Takashi ;
Uejima, Tokuhisa ;
Tanaka, Tomohiko ;
Ono, Minoru ;
Miyaji, Kagami ;
Takenaka, Katsu .
JAPANESE JOURNAL OF APPLIED PHYSICS, 2013, 52 (07)
[7]   Immediate impairment of left ventricular mechanical performance and force-frequency relation by rate-responsive dual-chamber, but not atrial pacing: Implications from intraventricular isovolumic relaxation flow [J].
Lin, Mao-Shin ;
Lin, Jiunn-Lee ;
Liu, Yen-Bin ;
Wu, Chau-Chung ;
Lin, Lung-Chun ;
Chen, Ming-Fong .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 109 (03) :367-374
[8]   DIASTOLIC SUCTION IN THE HUMAN VENTRICLE - OBSERVATION DURING BALLOON MITRAL VALVULOPLASTY WITH A SINGLE BALLOON [J].
NAKATANI, S ;
BEPPU, S ;
NAGATA, S ;
ISHIKURA, F ;
TAMAI, J ;
YAMAGISHI, M ;
OHMORI, F ;
KIMURA, K ;
TAKAMIYA, M ;
MIYATAKE, K .
AMERICAN HEART JOURNAL, 1994, 127 (01) :143-147
[9]   Diastolic suction in heart failure: Impact of left ventricular geometry, untwist, and flow mechanics [J].
Nogami, Yoshie ;
Ishizu, Tomoko ;
Atsumi, Akiko ;
Yamamoto, Masayoshi ;
Nakamura, Akihiro ;
Machino-Ohtsuka, Tomoko ;
Kawamura, Ryo ;
Seo, Yoshihiro ;
Aonuma, Kazutaka .
LIFE SCIENCES, 2014, 102 (02) :111-117
[10]   Ventricular untwisting: a temporal link between left ventricular relaxation and suction [J].
Notomi, Yuichi ;
Popovic, Zoran B. ;
Yamada, Hirotsugu ;
Wallick, Don W. ;
Martin, Maureen G. ;
Oryszak, Stephanie J. ;
Shiota, Takahiro ;
Greenberg, Neil L. ;
Thomas, James D. .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2008, 294 (01) :H505-H513