Evaluation of prosthetic valve dysfunctioning

被引:0
|
作者
Cinar, CS [1 ]
Gurgun, C [1 ]
机构
[1] Ege Univ, Fac Med, Dept Cardiol, Izmir, Turkey
来源
PROCEEDINGS OF THE 5TH WORLD CONGRESS OF ECHOCARDIOGRAPHY AND VASCULAR ULTRASOUND | 2001年
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Although significant modifications in valve design, prosthetic materials, and surgical techniques have improved prosthetic valve function, the hemodynamic profile of prosthetic valves is still inferior to that of native valves.(1) Complications after cardiac valvular operations include structural valvular deterioration (wear, racture, poppet escape, calcification, leaflet tear), nonstructural dysfunction (entrapment by pannus, tissue or suture; paravalvular leak, inappropriate sizing or positioning and hemolytic anemia), valve thrombosis, embolism, bleeding events and endocarditis. Changes in baseline auscultatory findings and clinical presentation of dyspnea, exercise intolerance, or embolic phenomenon should prompt an evaluation of prosthetic function.
引用
收藏
页码:63 / 72
页数:10
相关论文
共 50 条
  • [1] ECHOCARDIOGRAPHIC EVALUATION OF DYSFUNCTIONING PROSTHETIC VALVES
    ALAM, M
    LAKIER, JB
    PICKARD, SD
    MAGILLIGAN, DJ
    GOLDSTEIN, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 1 (02) : 604 - 604
  • [2] PHONOMECHANOCARDIOGRAPHIC DIAGNOSIS OF DYSFUNCTIONING PROSTHETIC VALVES
    VEYRAT, C
    KALMANSON, D
    WITCHITZ, S
    SEBAN, C
    SENIKIES, A
    CHICHE, P
    COEUR ET MEDECINE INTERNE, 1975, 14 (02): : 265 - 283
  • [3] Prosthetic mitral valve evaluation
    Louie, EK
    Konstadt, S
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1996, 10 (06) : 823 - 824
  • [4] EVALUATION AND MANAGEMENT OF PROSTHETIC VALVE ENDOCARDITIS
    MAYER, KH
    SCHOENBAUM, SC
    PROGRESS IN CARDIOVASCULAR DISEASES, 1982, 25 (01) : 43 - 54
  • [5] ULTRASONIC EVALUATION OF PROSTHETIC VALVE MOTION
    JOHNSON, ML
    PATON, BC
    HOLMES, JH
    CIRCULATION, 1970, 41 (05) : II3 - &
  • [6] Fatigue evaluation of a prosthetic heart valve
    Crompton, J.
    Dydo, J.
    Koppenhoefer, K.
    Yushanov, S.
    Canchi, S.
    MEDICAL DEVICE MATERIALS III: PROCEEDINGS FROM THE MATERIALS & PROCESSES FOR MEDICAL DEVICES CONFERENCE 2005, 2006, : 123 - +
  • [7] Echocardiographic evaluation of prosthetic valve endocarditis
    Ozer, Necla
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2008, 36 (03): : 190 - 196
  • [8] Evaluation of Prosthetic Valve Dysfunction With the Use of Echocardiography
    Beigel, Roy
    Siegel, Robert J.
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2014, 15 (04) : 332 - 350
  • [9] Doppler echocardiographic evaluation of prosthetic valve function
    Pibarot, Philippe
    Dumesnil, Jean G.
    HEART, 2012, 98 (01) : 69 - 78
  • [10] Cardiac CTA for Evaluation of Prosthetic Valve Dysfunction
    Feuchtner, Gudrun
    Plank, Fabian
    Mueller, Silvana
    Schachner, Thomas
    Bonaros, Nikolaos
    Burghard, Philipp
    Wolf, Florian
    Alhassan, Donya-el
    Blanke, Philip
    Leipsic, Jonathon
    Alkadhi, Hatem
    Plass, Andre
    Felmly, Lloyd M.
    Spandorfer, Adam J.
    De Cecco, Carlo N.
    Schoepf, U. Joseph
    JACC-CARDIOVASCULAR IMAGING, 2017, 10 (01) : 91 - 93