Radioscopy and computed tomography for failure analysis using microfocus X-ray

被引:0
|
作者
Bossi, RH
Cross, DA
Mickelsen, RA
机构
来源
NONDESTRUCTIVE EVALUATION OF MATERIALS AND COMPOSITES | 1996年 / 2944卷
关键词
D O I
10.1117/12.259063
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
X-ray microfocus radioscopy and computed tomography (CT) offer detailed information on the internal assembly and material condition of objects under failure analysis investigation. Using advanced systems for the acquisition of radioscopic and CT images, failure analysis investigations are improved in technical accuracy at a reduced schedule and cost over alternative approaches. A versatile microfocus radioscopic system with CT capability has been successfully implemented as a standard tool in the Boeing Defense gr Space Group Failure Analysis Laboratory. Using this tool, studies of electronic, electromechanical and composite material items have been performed. Such a system can pay for itself within two years through higher productivity of the laboratory, increased laboratory value to the company and resolution of critical problems whose worth far exceeds the value of the equipment. The microfocus X-ray source provides projection magnification images that exceed the sensitivity to fine detail that can be obtained with conventional film radiography. Radioscopy, which provides real-time images on a video monitor, allows objects to be readily manipulated and oriented for optimum x-ray evaluation, or monitored during dynamic processes to check performance. Combined with an accurate manipulating stage and data acquisition system x-ray measurements can be used for CT image reconstruction. The CT image provides a cross sectional view of the interior of an object without the interference of superposition of features found in conventional radiography. Accurate dimensional measurements and material constituent identification are possible from the CT images. By taking multiple, contiguous CT slices entire three dimensional data files can be generated of objects.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 50 条
  • [1] Microfocus x-ray inspection with radioscopy and computed tomography
    Nuding, W
    Sauerwein, C
    Schekira, S
    Wiacker, H
    EUROMAT 97 - PROCEEDINGS OF THE 5TH EUROPEAN CONFERENCE ON ADVANCED MATERIALS AND PROCESSES AND APPLICATIONS: MATERIALS, FUNCTIONALITY & DESIGN, VOL 4: CHARACTERIZATION AND PRODUCTION/DESIGN, 1997, : 159 - 162
  • [2] An Analysis of the Slow Compression Breakage of Coal Using Microfocus X-Ray Computed Tomography
    Viljoen, Jacob
    Campbell, Quentin Peter
    Le Roux, Marco
    De Beer, Frikkie
    INTERNATIONAL JOURNAL OF COAL PREPARATION AND UTILIZATION, 2015, 35 (01) : 1 - 13
  • [3] Microfocus X-ray computed tomography analysis of corroded glass objects
    Mees, Florias
    Cornelis, Etienne
    Jacobs, Patric
    Domenech Carbo, Maria Teresa
    Roemich, Hannelore
    ENGINEERING GEOLOGY, 2009, 103 (3-4) : 93 - 99
  • [4] Failure analysis using microfocus X-ray imaging
    Bossi, RH
    JOURNAL OF TESTING AND EVALUATION, 1999, 27 (02) : 137 - 142
  • [5] Microstructure observation in deformed geomaterials using microfocus X-ray computed tomography
    Takemura, T
    Oda, A
    Takahashi, A
    X-RAY CT FOR GEOMATERIALS SOILS, CONCRETE, ROCKS, 2004, : 299 - 304
  • [6] Age estimation using microfocus X-ray computed tomography of lower premolars
    Aboshi, H.
    Takahashi, T.
    Komuro, T.
    FORENSIC SCIENCE INTERNATIONAL, 2010, 200 (1-3) : 35 - 40
  • [7] MICROFOCUS X-RAY COMPUTED TOMOGRAPHY (CT) ANALYSIS OF LASER SINTERED PARTS
    du Plessis, A.
    Seifert, T.
    Booysen, G.
    Els, J.
    SOUTH AFRICAN JOURNAL OF INDUSTRIAL ENGINEERING, 2014, 25 (01): : 39 - 49
  • [8] Progress of microfocus X-ray systems for fluoroscopic and computed tomography
    Hirakimoto, A
    Ohnishi, S
    Maeda, H
    Kishi, T
    Shiota, T
    Tamura, T
    Ukita, M
    Fujita, S
    Kamegawa, M
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (08) : 1101 - 1106
  • [9] Microstructure in shear band observed by microfocus X-ray computed tomography
    Oda, M
    Takemura, T
    Takahashi, M
    GEOTECHNIQUE, 2005, 55 (04): : 333 - 335
  • [10] Microstructure in shear band observed by microfocus X-ray computed tomography
    Oda, M
    Takemura, T
    Takahashi, M
    GEOTECHNIQUE, 2004, 54 (08): : 539 - 542