Active alignment for two-beam interferometers

被引:11
作者
Kalamatianos, D [1 ]
Wellstead, PE
Edmunds, JM
Liatsis, P
机构
[1] Natl Univ Ireland, Hamilton Inst, Maynooth, Kildare, Ireland
[2] Acimet Ltd, Manchester M15 6JJ, Lancs, England
[3] City Univ London, Sch Engn & Math Sci, London EC1V 0HB, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1063/1.2150823
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An active control system is described for the automatic alignment of the mirrors in a two-beam interferometer. From an initial unaligned position the active control system determines the degree of misalignment and adjusts the relative mirror positions accordingly. An embodiment of the system is described for a Michelson interferometer in which one of the mirrors is mounted upon three piezoelectric transducers (PZT) arranged so that they can both tilt and retard the mirror. Laser sources and corresponding photodetectors are also incorporated such that a control system can use the PZT actuators to produce a series of mirror movements relative to the fixed mirror and give a set of two-dimensional diffraction patterns-one for each of the laser photodetectors. Amplitude and phase information is extracted from these patterns which enables the control system to align the mirrors such that the diffraction pattern maxima is at the center of the instrument central photodetector. In a further stage of the control algorithm, the alignment accuracy is refined using information from the laser photodetectors during retardation of the mirror. In this manner, the initial mirror alignment, maintaining that alignment during retardation and diagnosis of possible misalignment, become part of a single active control technology for instrument alignment. (c) 2006 American Institute of Physics.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 14 条
  • [1] AUTOMATIC ALIGNMENT OF A MICHELSON INTERFEROMETER
    BARONE, F
    DIFIORE, L
    MILANO, L
    RUSSO, G
    SOLIMENO, S
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (02) : 232 - 237
  • [2] Uniform time-sampling Fourier transform spectroscopy
    Brasunas, JC
    Cushman, GM
    [J]. APPLIED OPTICS, 1997, 36 (10): : 2206 - 2210
  • [3] Performance degradation of a Michelson interferometer when its misalignment angle is a rapidly varying, random time series
    Cohen, DL
    [J]. APPLIED OPTICS, 1997, 36 (18): : 4034 - 4042
  • [4] Connes J., 1961, Rev. Opt, V40, P45
  • [5] Fourier transform interferometer alignment method
    Goldberg, KA
    Naulleau, P
    Bokor, J
    [J]. APPLIED OPTICS, 2002, 41 (22) : 4477 - 4483
  • [6] GRIFFITHS P, 1986, FOURIER TRANSFORM I
  • [7] HARRIS FJ, 1978, P IEEE, V66, P51, DOI 10.1109/PROC.1978.10837
  • [8] Dynamic alignment system for an FT-NIR Michelson interferometer
    Kalamatianos, D
    Edmunds, JM
    Wellstead, PE
    Houston, RJ
    Liatsis, P
    Christie, SM
    Dewhurst, RJ
    Thomiley, MS
    [J]. 2004 IEEE SYMPOSIUM ON VIRTUAL ENVIRONMENTS, HUMAN-COMPUTRE INTERFACES AND MEASUREMENT SYSTEMS, 2004, : 120 - 124
  • [9] A DYNAMIC ALIGNMENT SYSTEM FOR SCANNING MICHELSON INTERFEROMETERS
    LU, ZJ
    KOEHLER, RA
    GAULT, WA
    LIANG, FC
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1988, 21 (01): : 71 - 74
  • [10] AUTOMATIC ALIGNMENT OF OPTICAL INTERFEROMETERS
    MORRISON, E
    MEERS, BJ
    ROBERTSON, DI
    WARD, H
    [J]. APPLIED OPTICS, 1994, 33 (22): : 5041 - 5049