Quality of Data Entry Using Single Entry, Double Entry and Automated Forms Processing-An Example Based on a Study of Patient-Reported Outcomes

被引:85
作者
Paulsen, Aksel [1 ,2 ]
Overgaard, Soren [1 ,2 ]
Lauritsen, Jens Martin [1 ,3 ]
机构
[1] Odense Univ Hosp, Dept Orthopaed Surg & Traumatol, DK-5000 Odense, Funen, Denmark
[2] Univ So Denmark, Inst Clin Res, Odense, Funen, Denmark
[3] Univ So Denmark, Inst Publ Hlth, Dept Biostat, Odense, Funen, Denmark
来源
PLOS ONE | 2012年 / 7卷 / 04期
关键词
TOTAL HIP-REPLACEMENT; TEXT; TELEFORM(TM); VALIDITY; ERRORS; SCALE;
D O I
10.1371/journal.pone.0035087
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: The clinical and scientific usage of patient-reported outcome measures is increasing in the health services. Often paper forms are used. Manual double entry of data is defined as the definitive gold standard for transferring data to an electronic format, but the process is laborious. Automated forms processing may be an alternative, but further validation is warranted. Methods: 200 patients were randomly selected from a cohort of 5777 patients who had previously answered two different questionnaires. The questionnaires were scanned using an automated forms processing technique, as well as processed by single and double manual data entry, using the EpiData Entry data entry program. The main outcome measure was the proportion of correctly entered numbers at question, form and study level. Results: Manual double-key data entry (error proportion per 1000 fields = 0.046 (95% CI: 0.001-0.258)) performed better than single-key data entry (error proportion per 1000 fields = 0.370 (95% CI: 0.160-0.729), (p = 0.020)). There was no statistical difference between Optical Mark Recognition (error proportion per 1000 fields = 0.046 (95% CI: 0.001-0.258)) and double-key data entry (p = 1.000). With the Intelligent Character Recognition method, there was no statistical difference compared to single-key data entry (error proportion per 1000 fields = 6.734 (95% CI: 0.817-24.113), (p = 0.656)), as well as double-key data entry (error proportion per 1000 fields = 3.367 (95% CI: 0.085-18.616)), (p = 0.319)). Conclusions: Automated forms processing is a valid alternative to double manual data entry for highly structured forms containing only check boxes, numerical codes and no dates. Automated forms processing can be superior to single manual data entry through a data entry program, depending on the method chosen.
引用
收藏
页数:6
相关论文
共 35 条
[21]  
Nakano Y., 1986, Eighth International Conference on Pattern Recognition. Proceedings (Cat. No.86CH2342-4), P801
[22]   Hip disability and osteoarthritis outcome score (HOOS) -: validity and responsiveness in total hip replacement -: art. no. 10 [J].
Nilsdotter, AK ;
Lohmander, LS ;
Klässbo, M ;
Roos, EM .
BMC MUSCULOSKELETAL DISORDERS, 2003, 4 (1) :1-8
[23]   ASSESSMENT OF QUALITY-OF-LIFE IN SURGERY [J].
OBOYLE, CA .
BRITISH JOURNAL OF SURGERY, 1992, 79 (05) :395-398
[24]   Standard requirements for GCP-compliant data management in multinational clinical trials [J].
Ohmann, Christian ;
Kuchinke, Wolfgang ;
Canham, Steve ;
Lauritsen, Jens ;
Salas, Nader ;
Schade-Brittinger, Carmen ;
Wittenberg, Michael ;
McPherson, Gladys ;
McCourt, John ;
Gueyffier, Francois ;
Lorimer, Andrea ;
Torres, Ferran .
TRIALS, 2011, 12
[25]  
Paulsen A, 2012, ACTA ORTHOP IN PRESS
[26]  
Protti Denis, 2006, Inform Prim Care, V14, P93
[27]  
Rieder HL, 2011, INT J TUBERC LUNG D, V15, P296
[28]  
Rolfson O., 2010, Patient-reported Outcome Measures and Health-economic Aspects of Total Hip Arthroplasty
[29]  
Toyoda J., 1982, Proceedings of the 6th International Conference on Pattern Recognition, P1113
[30]  
Tsujimoto S., 1990, Proceedings. 10th International Conference on Pattern Recognition (Cat. No.90CH2898-5), P551, DOI 10.1109/ICPR.1990.118163