Quality of Data Entry Using Single Entry, Double Entry and Automated Forms Processing-An Example Based on a Study of Patient-Reported Outcomes

被引:85
作者
Paulsen, Aksel [1 ,2 ]
Overgaard, Soren [1 ,2 ]
Lauritsen, Jens Martin [1 ,3 ]
机构
[1] Odense Univ Hosp, Dept Orthopaed Surg & Traumatol, DK-5000 Odense, Funen, Denmark
[2] Univ So Denmark, Inst Clin Res, Odense, Funen, Denmark
[3] Univ So Denmark, Inst Publ Hlth, Dept Biostat, Odense, Funen, Denmark
来源
PLOS ONE | 2012年 / 7卷 / 04期
关键词
TOTAL HIP-REPLACEMENT; TEXT; TELEFORM(TM); VALIDITY; ERRORS; SCALE;
D O I
10.1371/journal.pone.0035087
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: The clinical and scientific usage of patient-reported outcome measures is increasing in the health services. Often paper forms are used. Manual double entry of data is defined as the definitive gold standard for transferring data to an electronic format, but the process is laborious. Automated forms processing may be an alternative, but further validation is warranted. Methods: 200 patients were randomly selected from a cohort of 5777 patients who had previously answered two different questionnaires. The questionnaires were scanned using an automated forms processing technique, as well as processed by single and double manual data entry, using the EpiData Entry data entry program. The main outcome measure was the proportion of correctly entered numbers at question, form and study level. Results: Manual double-key data entry (error proportion per 1000 fields = 0.046 (95% CI: 0.001-0.258)) performed better than single-key data entry (error proportion per 1000 fields = 0.370 (95% CI: 0.160-0.729), (p = 0.020)). There was no statistical difference between Optical Mark Recognition (error proportion per 1000 fields = 0.046 (95% CI: 0.001-0.258)) and double-key data entry (p = 1.000). With the Intelligent Character Recognition method, there was no statistical difference compared to single-key data entry (error proportion per 1000 fields = 6.734 (95% CI: 0.817-24.113), (p = 0.656)), as well as double-key data entry (error proportion per 1000 fields = 3.367 (95% CI: 0.085-18.616)), (p = 0.319)). Conclusions: Automated forms processing is a valid alternative to double manual data entry for highly structured forms containing only check boxes, numerical codes and no dates. Automated forms processing can be superior to single manual data entry through a data entry program, depending on the method chosen.
引用
收藏
页数:6
相关论文
共 35 条
[1]  
Abele L., 1981, P 2 SCAND C IM AN, P177
[2]   INTERACTIVE SYSTEM FOR READING UNFORMATTED PRINTED TEXT [J].
ASCHER, RN ;
KOPPELMAN, GM ;
MILLER, MJ ;
NAGY, G ;
SHELTON, GL .
IEEE TRANSACTIONS ON COMPUTERS, 1971, C 20 (12) :1527-+
[3]  
Biondich PG, 2002, AMIA 2002 SYMPOSIUM, PROCEEDINGS, P56
[4]   EuroQol: The current state of play [J].
Brooks, R .
HEALTH POLICY, 1996, 37 (01) :53-72
[5]  
Casey R., 1992, Machine Vision and Applications, V5, P143, DOI 10.1007/BF02626994
[6]  
Ciardiello G., 1988, P INT C PATT REC, P739
[7]   Questionnaire on the perceptions of patients about total hip replacement [J].
Dawson, J ;
Fitzpatrick, R ;
Carr, A ;
Murray, D .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (02) :185-190
[8]  
Esposito F., 1990, Proceedings. 10th International Conference on Pattern Recognition (Cat. No.90CH2898-5), P557, DOI 10.1109/ICPR.1990.118164
[9]  
Goldberg Saveli I, 2008, AMIA Annu Symp Proc, P242
[10]   Data collection in a multisite project:: Teleform™ [J].
Hardin, JM ;
Woodby, LL ;
Crawford, MA ;
Windsor, RA ;
Miller, TM .
PUBLIC HEALTH NURSING, 2005, 22 (04) :366-370