Intensity of oral anticoagulation after implantation of St. Jude Medical aortic prosthesis: analysis of the GELIA Database (GELIA 4)

被引:25
作者
Huth, C [1 ]
Friedl, A [1 ]
Rost, A [1 ]
机构
[1] Otto Von Guericke Univ, Fak Med, Klin Herz & Thoraxchirurg, D-39120 Magdeburg, Germany
关键词
aortic valve replacement; bleeding complications; German Experience with Low Intensity Anticoagulation (GELIA) study; low-intensity oral anticoagulation; thromboembolic events; St. Jude Medical prostheses; survival rate;
D O I
10.1016/S1520-765X(01)90040-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims No prospective studies exist that define the ideal target International Normalized Ratio (INR) with respect to anticoagulation-related complications and survival rates after valve replacement with mechanical prostheses. The purpose of the present analysis is to determine optimal levels of anticoagulation for St. Jude Medical mechanical aortic prostheses (St. Jude Medical, Inc., St. Paul, MN, U.S.A.). Method Patients who received a St. Jude Medical mechanical prosthesis were randomized to three ranges of INR for postoperative oral anticoagulation: stratum A, INR 3.0-4.5; stratum B, INR 2.5-4.0; and stratum C, INR 2.0-3-5. This intent-to-treat analysis is based on the assigned range, not the actual range. Results In total, 2024 patients with aortic valves were included in the German Experience with Low Intensity Anticoagulation. (GELIA) study, with 672, 677 and 675 patients in strata A, B and C, respectively. The percentages of patients who achieved an INR within their target range in each stratum are as follows: 43(.)3% in stratum A; 62(.)8% in stratum B; and 75(.)9% in stratum C. Patients who self-managed their anticoagulation therapy achieved an INR within their target range more often than did those who were managed by conventional methods. No statistically significant differences in adverse event rates were identified between strata. Conclusion A target INR range of 2(.)0-3(.)5 is preferable to the usual 3(.)0-4(.)5 range in reducing the number of severe bleeding complications in patients implanted with a St. Jude Medical prosthesis. Self-management of INR may result in better achievement of target INR levels. (C) 2001 The European Society of Cardiology.
引用
收藏
页码:Q33 / Q38
页数:6
相关论文
共 52 条
[1]   MECHANICAL CARDIAC VALVULAR PROSTHESES [J].
AKINS, CW .
ANNALS OF THORACIC SURGERY, 1991, 52 (01) :161-172
[2]  
ALTMAN R, 1991, J THORAC CARDIOV SUR, V101, P427
[3]  
ARIS A, 1992, J THORAC CARDIOV SUR, V103, P1074
[4]   10 YEARS EXPERIENCE WITH THE ST JUDE MEDICAL VALVE PROSTHESIS [J].
AROM, KV ;
NICOLOFF, DM ;
KERSTEN, TE ;
NORTHRUP, WF ;
LINDSAY, WG ;
EMERY, RW .
ANNALS OF THORACIC SURGERY, 1989, 47 (06) :831-837
[5]  
Bernardo A, 1998, Z KARDIOL, V87, P75
[6]  
BINET JP, 1965, LANCET, V2, P1275
[7]   Prosthetic valve type for patients undergoing aortic valve replacement: A decision analysis [J].
Birkmeyer, NJO ;
Birkmeyer, JD ;
Tosteson, ANA ;
Grunkemeier, GL ;
Marrin, CAS ;
O'Connor, GT .
ANNALS OF THORACIC SURGERY, 2000, 70 (06) :1946-1952
[8]   Guidelines for the management of patients with valvular heart disease - Executive summary - A report of the American College of Cardiology American Heart Association task force on practice guidelines (committee on management of patients with valvular heart disease) [J].
Bonow, RO ;
Carabello, B ;
de Leon, AC ;
Edmunds, LH ;
Fedderly, BJ ;
Freed, MD ;
Gaasch, WH ;
McKay, CR ;
Nishimura, RA ;
O'Gara, PT ;
O'Rourke, RA ;
Rahimtoola, SH ;
Ritchie, JL ;
Cheitlin, MD ;
Eagle, KA ;
Gardner, TJ ;
Garson, A ;
Gibbons, RJ ;
Russell, RO ;
Ryan, TJ ;
Smith, SC .
CIRCULATION, 1998, 98 (18) :1949-1984
[9]   INFLUENCE OF TYPE OF PROSTHESIS ON LATE RESULTS AFTER COMBINED MITRAL-AORTIC VALVE-REPLACEMENT [J].
BORTOLOTTI, U ;
MILANO, A ;
TESTOLIN, L ;
TURSI, V ;
MAZZUCCO, A ;
GALLUCCI, V .
ANNALS OF THORACIC SURGERY, 1991, 52 (01) :84-91
[10]  
BUTCHART EG, 1991, CIRCULATION, V84, P61