Cortisol and cortisone ratio in urine: LC-MS/MS method validation and preliminary clinical application

被引:25
作者
Antonelli, Giorgia [4 ]
Artusi, Carlo [1 ]
Marinova, Mariela [1 ]
Brugnolo, Laura [1 ]
Zaninotto, Martina [1 ]
Scaroni, Carla [2 ]
Gatti, Rosalba [3 ]
Mantero, Franco [2 ]
Plebani, Mario [1 ,4 ]
机构
[1] Univ Hosp Padova, Dept Lab Med, Padua, Italy
[2] Univ Padua, Dept Med, UO Endocrinol, Padua, Italy
[3] Univ Hosp Padova, UO Endocrinol, Padua, Italy
[4] Univ Padua, Dept Med, UOC Lab Med, I-35128 Padua, Italy
关键词
cortisol; cortisone; liquid chromatography; ratio; reference range; tandem mass spectrometry; TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; DIAGNOSIS; SPECIFICITY; PLASMA; SERUM;
D O I
10.1515/cclm-2013-0471
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The determination of urinary cortisol/cortisone ratio is of clinical utility in cases of Cushing's syndrome, apparent mineralocorticoid excess, and also provides information on 11 beta-hydroxysteroid dehydrogenase (11 beta-HSD) type 2 activity. It is therefore of utmost importance to ensure accurate cortisol and cortisone measurement and establish appropriate reference ranges. Methods: After the isotopic dilution of urine, sample cleanups were obtained with on-line solid-phase extraction and cortisol and cortisone, separated using a Zorbax Eclipse XDB-C18 HPLC analytical column, were analyzed by tandem mass spectrometry with an electrospray ionization source in positive ion mode operation. Results: The method was linear, with concentrations of up to 625 and 1125 nmol/L and lower limit of quantitation (LLOQ) of 5 and 6 nmol/L, for cortisol and cortisone, respectively. Within-run and between-run coefficients of variation were <5% and 6% for cortisol and 6% and 8% for cortisone, respectively. No ion suppression was observed. The non-parametric reference range for the cortisol/cortisone ratio was 0.14-1.09. Conclusions: A simple and sensitive liquid chromatography tandem mass spectrometry method was developed and validated for the measurement of cortisol and cortisone in urine. Our findings indicate that the proposed analytical method is suitable for routine purposes and useful in many pathological conditions.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 29 条
[1]   Is urinary free cortisol of value in the diagnosis of Cushing's syndrome? [J].
Alexandraki, Krystallenia I. ;
Grossman, Ashley B. .
CURRENT OPINION IN ENDOCRINOLOGY DIABETES AND OBESITY, 2011, 18 (04) :259-263
[2]   Pseudohypercortisoluria: Spurious elevation of urinary cortisol due to carbamazepine [J].
Findling, JW ;
Pinkstaff, SM ;
Shaker, JL ;
Raff, H ;
Nelson, JC .
ENDOCRINOLOGIST, 1998, 8 (02) :51-54
[3]   Improved liquid chromatography-tandem mass spectrometry method in clinical utility for the diagnosis of Cushing's syndrome [J].
Fong, Bonnie Mei-Wah ;
Tam, Sidney ;
Leung, Kelvin Sze-Yin .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (02) :783-790
[4]  
Gatti R, 2005, J CHROMATOGR B, V829, P153, DOI 10.1016/j.jchromb.2005.11.019
[5]   Cortisol assays and diagnostic laboratory procedures in human biological fluids [J].
Gatti, Rosalba ;
Antonelli, Giorgia ;
Prearo, Maddalena ;
Spinella, Paolo ;
Cappellin, Enrico ;
De Palo, Elio F. .
CLINICAL BIOCHEMISTRY, 2009, 42 (12) :1205-1217
[6]   Poor specificity and recovery of urinary free cortisol as determined by the Bayer ADVIA Centaur extraction method [J].
Gray, G ;
Shakerdi, L ;
Wallace, AM .
ANNALS OF CLINICAL BIOCHEMISTRY, 2003, 40 :563-565
[7]   Improved determination of urinary cortisol and cortisone, or corticosterone and 11-dehydrocorticosterone by high-performance liquid chromatography with ultraviolet absorbance detection [J].
Hay, M ;
Mormède, P .
JOURNAL OF CHROMATOGRAPHY B, 1997, 702 (1-2) :33-39
[8]   Specificity assessment of immunoassay kits for determination of urinary free cortisol concentrations [J].
Horie, Hitoshi ;
Kidowaki, Takeshi ;
Koyama, Yuhei ;
Endo, Tatsuji ;
Homma, Keiko ;
Kambegawa, Akira ;
Aoki, Norihiko .
CLINICA CHIMICA ACTA, 2007, 378 (1-2) :66-70
[9]   Measurement of urinary free cortisol using the ACS:180 serum cortisol chemiluminescent immunoassay [J].
Kennedy, DM ;
Selby, C ;
Lawson, N .
ANNALS OF CLINICAL BIOCHEMISTRY, 2000, 37 :520-528
[10]   Liquid chromatography tandem mass spectrometry for analysis of steroids in clinical laboratories [J].
Kushnir, Mark M. ;
Rockwood, Alan L. ;
Roberts, William L. ;
Yue, Bingfang ;
Bergquist, Jonas ;
Meikle, A. Wayne .
CLINICAL BIOCHEMISTRY, 2011, 44 (01) :77-88