High-Throughput Quantitative Analysis by Desorption Electrospray Ionization Mass Spectrometry

被引:79
作者
Manicke, Nicholas E. [1 ]
Kistler, Thomas [1 ]
Ifa, Demian R. [1 ]
Cooks, R. Graham [1 ]
Ouyang, Zheng [1 ]
机构
[1] Purdue Univ, Dept Chem, Bindley Biosci Ctr, W Lafayette, IN 47907 USA
基金
美国国家科学基金会;
关键词
AMBIENT CONDITIONS; ATMOSPHERIC-PRESSURE; ION-SOURCE; PLASMA; DRUGS; DESI; SAMPLES; SOLIDS; URINE;
D O I
10.1016/j.jasms.2008.10.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A newly developed high-throughput desorption electrospray ionization (DEST) Source was characterized in tern-is of its performance in quantitative analysis. A 96-sample array, containing pharmaceuticals in various matrices, was analyzed in a single run with a total analysis time of 3 min. These solution-phase samples were examined from a hydrophobic PTFE ink printed on glass. The quantitative accuracy, precision, and limit of detection (LOD) were characterized. Chemical background-free samples of propranolol (PRN) with PRN-d(7) as internal standard (IS) and carbamazepine (CBZ) with CBZ-d(10) as IS were examined. So were two other sample sets consisting of PRN/PRN-d(7) at varying concentration in a biological milieu of 10% urine or porcine brain total lipid extract, total lipid concentration 250 ng/mu L.The background-free samples, examined in a total analysis time of 1.5 s/sample, showed good quantitative accuracy and precision, with a relative error (RE) and relative standard deviation (RSD) generally less than 3% and 5% respectively. The samples in urine and the lipid extract required a longer analysis time (2.5 s/sample) and showed RSD Values of around 1.0% for the samples in urine and 4%, for the lipid extract samples and RE values of less than 3% for both sets. The LOD for PRN and CBZ when analyzed without chemical background was 10 and 30 fmol, respectively. The LOD of PRN increased to 400 fmol analyzed in 10% urine, and 200 fmol when analyzed in the brain lipid extract. (J Am Soc Mass Spectrom 2009, 20, 321-325) (C) 2009 Published by Elsevier Inc. on behalf of American Society for Mass Spectrometry
引用
收藏
页码:321 / 325
页数:5
相关论文
共 22 条
[1]   Detection of attomole amounts of analyte by desorption electrospray ionization mass spectrometry (DESI-MS) determined using fluorescence spectroscopy [J].
Bereman, Michael S. ;
Muddiman, David C. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (06) :1093-1096
[2]   Desorption electrospray ionization mass spectrometry for high-throughput analysis of pharmaceutical samples in the ambient environment [J].
Chen, HW ;
Talaty, NN ;
Takáts, Z ;
Cooks, RG .
ANALYTICAL CHEMISTRY, 2005, 77 (21) :6915-6927
[3]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[4]   Demonstration of direct bioanalysis of drugs in plasma using nanoelectrospray infusion from a silicon chip coupled with tandem mass spectrometry [J].
Dethy, JM ;
Ackermann, BL ;
Delatour, C ;
Henion, JD ;
Schultz, GA .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :805-811
[5]   Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry [J].
Hopfgartner, G ;
Bourgogne, E .
MASS SPECTROMETRY REVIEWS, 2003, 22 (03) :195-214
[6]   Rapid screening of anabolic steroids in urine by reactive Desorption Electrospray ionization [J].
Huang, Guangming ;
Chen, Hao ;
Zhang, Xinrong ;
Cooks, R. Graham ;
Ouyang, Zheng .
ANALYTICAL CHEMISTRY, 2007, 79 (21) :8327-8332
[7]   Quantitative analysis of small molecules by desorption electrospray ionization mass spectrometry from polytetrafluoroethylene surfaces [J].
Ifa, Demian R. ;
Manicke, Nicholas E. ;
Rusine, Allison L. ;
Cooks, R. Graham .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (04) :503-510
[8]   Development of capabilities for imaging mass spectrometry under ambient conditions with desorption electrospray ionization (DESI) [J].
Ifa, Demian R. ;
Wiseman, Justin M. ;
Song, Qingyu ;
Cooks, R. Graham .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 259 (1-3) :8-15
[9]   Rapid analysis of metabolites and drugs of abuse from urine samples by desorption electrospray ionization-mass spectrometry [J].
Kauppila, Tiina J. ;
Talaty, Nari ;
Kuuranne, Tiia ;
Kotiaho, Tapio ;
Kostiainen, Risto ;
Cooks, R. Graham .
ANALYST, 2007, 132 (09) :868-875
[10]   Scanning and surface alignment considerations in chemical imaging with desorption electrospray mass spectrometry [J].
Kertesz, Vilmos ;
van Berkel, Gary J. .
ANALYTICAL CHEMISTRY, 2008, 80 (04) :1027-1032