Scan-rescan variability in perfusion assessment of tumors in MRI using both model and data-derived arterial input functions

被引:55
作者
Ashton, Edward [1 ]
Raunig, David [2 ]
Ng, Chaan [3 ]
Kelcz, Fredrick [4 ]
McShane, Teresa [2 ]
Evelhoch, Jeffrey [5 ]
机构
[1] Virtualscop Inc, Rochester, NY 14625 USA
[2] Pfizer Global Res & Dev, Groton, CT USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiol, Houston, TX 77030 USA
[4] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[5] Amgen Inc, Thousand Oaks, CA USA
关键词
DCE-MRI; reproducibility; K-trans; arterial input function; IAUCBN(90);
D O I
10.1002/jmri.21472
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the contribution to scan-rescan coefficient of variation (CV) of patient-specific arterial input function (AIF) measurement in dynamic contrast-enhanced MRI (DCE-MRI) data, and to determine whether any advantage or disadvantage to using a data-derived arterial input function is related to the anatomical location of the target lesion. Materials and Methods: Two methods are presented for the calculation of perfusion parameters from DCE-MRI data using a two-compartment model. The first method makes use of a single-model AIF across all study data sets, while the second uses an automated process to derive an AIF specific to each data set. Both methods are applied to the analysis of a 25-subject scan-rescan study of patients with advanced solid tumors located in either the lungs or the liver. The parameters of interest in this study are the volume transfer constant between arterial plasma and extracellular extravascular space (K-trans) and the blood-normalized initial area under the tumor enhancement curve over the first 90 seconds postinjection (IAUCBN(90)). Results: The use of a data-derived AIF reduces the visit-to-visit CV in both parameters for liver lesions by approximately 70% while the improvement is less than 20% for lung lesions. Conclusion: The use of a data-derived AIF in the analysis of DCE-MRI data provides a substantial reduction in scan-rescan CV in the measurement of vascular parameters such as K-trans and IAUCBN90. These results show a much larger advantage in the liver than in the lungs. However, this difference is largely driven by a small number of outliers, and may be spurious.
引用
收藏
页码:791 / 796
页数:6
相关论文
共 20 条
[1]  
[Anonymous], INT J COMPUTER VISIO, DOI DOI 10.1007/BF00133570
[2]  
Ashton E, 2005, LECT NOTES COMPUT SC, V3749, P451
[3]  
Ashton EA, 2007, P 15 ANN M ISMRM BER
[4]  
Ashton EA, 2007, J IMAGING SCI TECHN, V51, P117, DOI [10.2352/J.ImagingSci.Technol.(2007)51:2(117), 10.2352/J.lmagingSci.Technol.(2007)51:2(117)]
[5]   AN ANALYSIS OF TRANSFORMATIONS [J].
BOX, GEP ;
COX, DR .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1964, 26 (02) :211-252
[6]  
Evelhoch JL, 1999, JMRI-J MAGN RESON IM, V10, P254, DOI 10.1002/(SICI)1522-2586(199909)10:3<254::AID-JMRI5>3.0.CO
[7]  
2-9
[8]   Reproducibility of dynamic contrast-enhanced MRI in human muscle and tumours: comparison of quantitative and semi-quantitative analysis [J].
Galbraith, SM ;
Lodge, MA ;
Taylor, NJ ;
Rustin, GJS ;
Bentzen, S ;
Stirling, JJ ;
Padhani, AR .
NMR IN BIOMEDICINE, 2002, 15 (02) :132-142
[9]   The assessment of antiangiogenic and antivascular therapies in early-stage clinical trials using magnetic resonance imaging: issues and recommendations [J].
Leach, MO ;
Brindle, KM ;
Evelhoch, JL ;
Griffiths, JR ;
Horsman, MR ;
Jackson, A ;
Jayson, GC ;
Judson, IR ;
Knopp, MV ;
Maxwell, RJ ;
McIntyre, D ;
Padhani, AR ;
Price, P ;
Rathbone, R ;
Rustin, GJ ;
Tofts, PS ;
Tozer, GM ;
Vennart, W ;
Waterton, JC ;
Williams, SR ;
Workmanw, P .
BRITISH JOURNAL OF CANCER, 2005, 92 (09) :1599-1610
[10]   Efficient method for calculating kinetic parameters using T1-weighted dynamic contrast-enhanced magnetic resonance imaging [J].
Murase, K .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) :858-862