Precise Fault Location in Distribution Networks Based on Optimal Monitor Allocation
被引:17
作者:
Sun, Haotian
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R ChinaXi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R China
Sun, Haotian
[1
]
Yi, Hao
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R ChinaXi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R China
Yi, Hao
[1
]
Zhuo, Fang
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R ChinaXi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R China
Zhuo, Fang
[1
]
Du, Xiaotong
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R ChinaXi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R China
Du, Xiaotong
[1
]
Yang, Guangyu
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R ChinaXi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R China
Yang, Guangyu
[1
]
机构:
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R China
Monitoring;
Voltage measurement;
Impedance;
Resource management;
Fault currents;
Current measurement;
Fault location;
distribution networks;
distributed generations;
linear least square method;
cosine similarity;
nonlinear optimization;
multi-objective optimization;
GENERATION;
D O I:
10.1109/TPWRD.2019.2954460
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
This article presents a novel fault-location method for unbalanced distribution networks in the presence of distributed generations. By utilizing the linear least square method, the candidate faulty lines are selected, and the injected fault currents are derived from the sparse voltage phasor measurements. According to the obtainability of the fault currents, two types of approaches are adopted for estimating the per-unit fault location. By taking advantage of the precise fault-location scheme, the actual faulted line and the accurate fault location are identified. Also, in order to compromise between the fault-location accuracy and the allocation costs, an optimal monitor-allocation algorithm is developed for determining the Pareto-optimal set of meter placements that have the minimal number of monitors to satisfy the requirements of fault-location accuracy. The proposed optimal allocation algorithm and the two types of fault-location approaches are validated on a modified IEEE 123-node test feeder using Matlab and Simulink.
引用
收藏
页码:1788 / 1799
页数:12