Intraoperative compensation for brain shift

被引:159
作者
Nimsky, C [1 ]
Ganslandt, O [1 ]
Hastreiter, P [1 ]
Fahlbusch, R [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Neurosurg, D-91054 Erlangen, Germany
来源
SURGICAL NEUROLOGY | 2001年 / 56卷 / 06期
关键词
accuracy; brain shift; intraoperative imaging; intraoperative magnetic resonance imaging; intraoperative ultrasound; neuronavigation;
D O I
10.1016/S0090-3019(01)00628-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND Tumor removal, brain swelling, the use of brain retractors, and cerebrospinal-fluid drainage all result in an intraoperative brain deformation that is known as brain shift. Thus, neuronavigation systems relying on preoperative image data have a decreasing accuracy during the surgical procedure. Intraoperative image data represent the correct anatomic situation, so their use may compensate for the effects of brain shift. METHODS In a series of 16 brain tumor patients, we used intraoperative magnetic resonance (MR) imaging to obtain 3-D data, which were then transferred to the microscope-based neuronavigation system. With the help of bone fiducial markers these images were registered intraoperatively, updating the neuronavigation system. RESULTS In all patients the updating of the neuronavigation system with the intraoperative MR data was successful, It led to reliable neuronavigation with high accuracy; the mean registration error of the update procedure in all patients was 1.1 mm. The updating procedure added about 15 minutes to the operation time. In all patients the area suggestive of remaining tumor was reached and the additional tumor could be resected, resulting in a complete tumor removal in 14 patients. In the remaining patients extension of the tumor into eloquent brain areas prevented a complete excision. CONCLUSIONS The update of a neuronavigation system with intraoperative MR images reliably compensates for the effects of brain shift. This method allows completion of tumor removal in some difficult brain tumors. (C) 2001 by Elsevier Science Inc.
引用
收藏
页码:357 / 364
页数:8
相关论文
共 36 条
[11]   Safety, efficacy, and functionality of high-field strength interventional magnetic resonance imaging for neurosurgery [J].
Hall, WA ;
Liu, HY ;
Martin, AJ ;
Pozza, CH ;
Maxwell, RE ;
Truwit, CL .
NEUROSURGERY, 2000, 46 (03) :632-641
[12]   Registration techniques for the analysis of the brain shift in neurosurgery [J].
Hastreiter, P ;
Rezk-Salama, C ;
Nimsky, C ;
Lürig, C ;
Greiner, G ;
Ertl, T .
COMPUTERS & GRAPHICS-UK, 2000, 24 (03) :385-389
[13]   Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration [J].
Hata, N ;
Dohi, T ;
Iseki, H ;
Takakura, K .
NEUROSURGERY, 1997, 41 (03) :608-613
[14]   Three-dimensional optical flow method for measurement of volumetric brain deformation from intraoperative MR images [J].
Hata, N ;
Nabavi, A ;
Wells, WM ;
Warfield, SK ;
Kikinis, R ;
Black, PM ;
Jolesz, FA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (04) :531-538
[15]   Measurement of intraoperative brain surface deformation under a craniotomy [J].
Hill, DLG ;
Maurer, CR ;
Maciunas, RJ ;
Barwise, JA ;
Fitzpatrick, JM ;
Wang, MY .
NEUROSURGERY, 1998, 43 (03) :514-526
[16]   Intraoperative three-dimensional ultrasonography: An approach to register brain shift using multidimensional image processing [J].
Jodicke, A ;
Deinsberger, W ;
Erbe, H ;
Kriete, A ;
Boker, DK .
MINIMALLY INVASIVE NEUROSURGERY, 1998, 41 (01) :13-19
[17]   COMPUTER-ASSISTED STEREOTAXIC LASER RESECTION OF INTRAAXIAL BRAIN NEOPLASMS [J].
KELLY, PJ ;
KALL, BA ;
GOERSS, S ;
EARNEST, F .
JOURNAL OF NEUROSURGERY, 1986, 64 (03) :427-439
[18]  
King AP, 2000, LECT NOTES COMPUT SC, V1935, P588
[19]   Investigation of intraoperative brain deformation using a 1.5-t interventional MR system: Preliminary results [J].
Maurer, CR ;
Hill, DLG ;
Martin, AJ ;
Liu, HY ;
McCue, M ;
Rueckert, D ;
Lloret, D ;
Hall, WA ;
Maxwell, RE ;
Hawkes, DJ ;
Truwit, CL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :817-825
[20]   In vivo modeling of interstitial pressure in the brain under surgical load using finite elements [J].
Miga, MI ;
Paulsen, KD ;
Hoopes, PJ ;
Kennedy, FE ;
Hartov, A ;
Roberts, DW .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (04) :354-363