Long-term follow-up of bone remodelling after cementless hip arthroplasty using different stems

被引:16
作者
Brodt, Steffen [1 ]
Matziolis, Georg [1 ]
Buckwitz, Bettina [2 ]
Zippelius, Timo [1 ]
Strube, Patrick [1 ]
Roth, Andreas [3 ]
机构
[1] Univ Hosp Jena, Orthopaed Dept Waldkliniken Eisenberg, Klosterlausnitzer Str 81, D-07607 Eisenberg, Germany
[2] Univ Hosp Jena, Dept Trauma Hand & Reconstruct Surg, Klinikum 1, D-07747 Jena, Germany
[3] Univ Hosp Leipzig, Clin Orthoped Traumatol & Plast Surg, Dept Arthroplasty Orthoped, Liebigstr 20, D-04103 Leipzig, Germany
关键词
TURNOVER; BMD;
D O I
10.1038/s41598-020-67189-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The present paper is concerned with the investigation of the phenomenon of long-term bone remodelling on cementless hip replacements. Changes in bone density in the periprosthetic region around the stem, measured by dual X-ray absorptiometry (DXA), were used as a measure of the osseous adaptation reaction. A postoperative follow-up of the use of four different types of prostheses of varying design after on average 13.3 (11.4-14.5) years. Specifically, the prostheses assessed in this study were the CLS/Spotorno stem with the Allofit cup by Zimmer, the Vision 2000 stem with the Duraloc cup by DePuy Synthes, the AlphaFit stem with the AlphaLock cup by Corin and the Mayo stem with the Trilogy cup by Zimmer. For the DXA measurement, the femur was divided into the zones suggested by Gruen et al. On the femur, there was a significant reduction in bone mineral density (BMD) in the proximal Region Of Interest (ROI) 1 (p=0.003) and 7 (p<0.001), whilst there was a significant increase in ROI 4 (p=0.03). A greater degree of bone atrophy was seen in patients aged 60 years and older and in female patients. A remarkable finding when comparing the stems was a significantly greater reduction in BMD in ROI 6 (p=0.003) in the case of the Vision 2000 stem and a markedly, but not statistically significantly smaller reduction in BMD in ROI 7 (p=0.18) in the case of the short-stem Mayo-type prosthesis. The best clinical results were found with the use of the latter. The investigations provide a starting point for establishing a differential indication in the choice of prosthesis types, depending on age and sex, the use of short-stem prostheses, as well as the administration of bone-effective drugs for the prevention of stress shielding.
引用
收藏
页数:7
相关论文
共 21 条
[1]   Pattern of periprosthetic bone remodeling around stable uncemented tapered hip stems: A prospective 84-month follow-up study and a median 156-month cross-sectional study with DXA [J].
Aldinger, PR ;
Sabo, D ;
Pritsch, M ;
Thomsen, M ;
Mau, H ;
Ewerbeck, V ;
Breusch, SJ .
CALCIFIED TISSUE INTERNATIONAL, 2003, 73 (02) :115-121
[2]   Female patients with low systemic BMD are prone to bone loss in Gruen zone 7 after cementless total hip arthroplasty A 2-year DXA follow-up of 39 patients [J].
Alm, Jessica J. ;
Makinen, Tatu J. ;
Lankinen, Petteri ;
Moritz, Niko ;
Vahlberg, Tero ;
Aro, Hannu T. .
ACTA ORTHOPAEDICA, 2009, 80 (05) :531-537
[3]   Continuous bone loss around a tapered uncemented femoral stem -: A long-term evaluation with DEXA [J].
Boden, Henrik S. G. ;
Skoldenberg, Olof G. ;
Salemyr, Mats F. ;
Lundberg, Hans-Jerker ;
Adolphson, Per Y. .
ACTA ORTHOPAEDICA, 2006, 77 (06) :877-885
[4]   Adoptive bone remodelling due to implantation of various stems in total hip arthroplasty. [J].
Eckardt, A ;
Karbowski, A ;
Schwitalle, M ;
Herbsthofer, B ;
Kreitner, KF .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (04) :355-360
[5]  
GRUEN TA, 1979, CLIN ORTHOP RELAT R, P17
[6]  
Hagel A, 2008, ACTA CHIR ORTHOP TR, V75, P288
[7]   The long-term clinical relevance of calcar atrophy caused by stress shielding in total hip arthroplasty - A 10-year, prospective, randomized study [J].
Karachalios, T ;
Tsatsaronis, C ;
Efraimis, G ;
Papadelis, P ;
Lyritis, G ;
Diakoumopoulos, G .
JOURNAL OF ARTHROPLASTY, 2004, 19 (04) :469-475
[8]   Cementless Femoral Fixation in Total Hip Arthroplasty [J].
Khanuja, Harpal S. ;
Vakil, Jeffrey J. ;
Goddard, Maria S. ;
Mont, Michael A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (05) :500-509
[9]   Periprosthetic bone loss and regional bone turnover in uncemented total hip arthroplasty: A prospective study using high resolution single photon emission tomography and dual-energy X-ray absorptiometry [J].
Kroger, H ;
Vanninen, E ;
Overmyer, M ;
Miettinen, H ;
Rushton, N ;
Suomalainen, O .
JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (03) :487-492
[10]   Bone remodeling around stable uncemented titanium stems during the second decade after total hip arthroplasty: a DXA study at 12 and 17 years [J].
Merle, C. ;
Streit, M. R. ;
Volz, C. ;
Pritsch, M. ;
Gotterbarm, T. ;
Aldinger, P. R. .
OSTEOPOROSIS INTERNATIONAL, 2011, 22 (11) :2879-2886