Biomechanical Measurements of Stiffness and Strength for Five Types of Whole Human and Artificial Humeri

被引:14
作者
Aziz, Mina S. R. [1 ,2 ]
Nicayenzi, Bruce [2 ]
Crookshank, Meghan C. [2 ]
Bougherara, Habiba [3 ]
Schemitsch, Emil H. [2 ,4 ]
Zdero, Radovan [2 ,3 ]
机构
[1] Univ Toronto, Inst Med Sci, Toronto, ON M5S 1A8, Canada
[2] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
[3] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON M5B 2K3, Canada
[4] Univ Toronto, Fac Med, Toronto, ON M5S 1A8, Canada
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2014年 / 136卷 / 05期
关键词
biomechanics; humerus; human; fresh-frozen; embalmed; dried; artificial; SURGICAL NECK FRACTURES; FINITE-ELEMENT-ANALYSIS; AGE-RELATED-CHANGES; TOTAL HIP IMPLANT; PROXIMAL HUMERUS; PLATE FIXATION; HUMAN FEMURS; BONE; SYSTEMS; SHAFT;
D O I
10.1115/1.4027057
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
`The human humerus is the third largest longbone and experiences 2-3% of all fractures. Yet, almost no data exist on its intact biomechanical properties, thus preventing researchers from obtaining a full understanding of humerus behavior during injury and after being repaired with fracture plates and nails. The aim of this experimental study was to compare the biomechanical stiffness and strength of "gold standard" fresh-frozen humeri to a variety of humerus models. A series of five types of intact whole humeri were obtained: human fresh-frozen (n = 19); human embalmed (n = 18); human dried (n = 15); artificial "normal" (n = 12); and artificial "osteoporotic" (n = 12). Humeri were tested under "real world" clinical loading modes for shear stiffness, torsional stiffness, cantilever bending stiffness, and cantilever bending strength. After removing geometric effects, fresh-frozen results were 585.8 +/- 181.5 N/mm(2) (normalized shear stiffness); 3.1 +/- 1.1 N/(mm(2) deg) (normalized torsional stiffness); 850.8 +/- 347.9 N/mm(2) (normalized cantilever stiffness); and 8.3 +/- 2.7 N/mm(2) (normalized cantilever strength). Compared to fresh-frozen values, statistical equivalence (p >= 0.05) was obtained for all four test modes (embalmed humeri), 1 of 4 test modes (dried humeri), 1 of 4 test modes (artificial "normal" humeri), and 1 of 4 test modes (artificial "osteoporotic" humeri). Age and bone mineral density versus experimental results had Pearson linear correlations ranging from R = -0.57 to 0.80. About 77% of human humeri failed via a transverse or oblique distal shaft fracture, whilst 88% of artificial humeri failed with a mixed transverse+oblique fracture. To date, this is the most comprehensive study on the biomechanics of intact human and artificial humeri and can assist researchers to choose an alternate humerus model that can substitute for fresh-frozen humeri.
引用
收藏
页数:10
相关论文
共 62 条
[1]   Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability? [J].
Ahmad, M. ;
Nanda, R. ;
Bajwa, A. S. ;
Candal-Couto, J. ;
Green, S. ;
Hui, A. C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (03) :358-364
[2]   The Biomechanical Effect of Torsion on Humeral Shaft Repair Techniques for Completed Pathological Fractures [J].
Al-Jahwari, Ahmed ;
Schemitsch, Emil H. ;
Wunder, Jay S. ;
Ferguson, Peter C. ;
Zdero, Rad .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (02)
[3]  
Allen MD, 2012, AGING DIS, V3, P156
[4]   Bone strength and its determinants [J].
Ammann, P ;
Rizzoli, R .
OSTEOPOROSIS INTERNATIONAL, 2003, 14 (Suppl 3) :S13-S18
[5]  
Baumgaertner M., 2005, ORTHOPAEDIC KNOWLEDG
[6]  
Calabrisi P., 1951, EFFECT EMBALMING COM
[7]  
CHIN HC, 1989, CLIN ORTHOP RELAT R, P231
[8]   Fixed-angle plate fixation in simulated fractures of the proximal humerus: A biomechanical study of a new device [J].
Chudik, SC ;
Weinhold, P ;
Dahners, LE .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (06) :578-588
[9]   Mechanical validation of whole bone composite femur models [J].
Cristofolini, L ;
Viceconti, M ;
Cappello, A ;
Toni, A .
JOURNAL OF BIOMECHANICS, 1996, 29 (04) :525-535
[10]   Biomechanical measurements of axial crush injury to the distal condyles of human and synthetic femurs [J].
Crookshank, Meghan ;
Coquim, Jason ;
Olsen, Michael ;
Schemitsch, Emil H. ;
Bougherara, Habiba ;
Zdero, Rad .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H4) :320-329