Determination of amitriptyline using electrogenerated chemiluminescence

被引:18
|
作者
Dolman, SJL [1 ]
Greenway, GM [1 ]
机构
[1] UNIV HULL,SCH CHEM,KINGSTON HULL HU6 7RX,N HUMBERSIDE,ENGLAND
来源
ANALYTICAL COMMUNICATIONS | 1996年 / 33卷 / 04期
关键词
D O I
10.1039/ac9963300139
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method for the selective and sensitive determination of amitriptyline, a tricyclic antidepressant, using electrogenerated chemiluminescence (ECL) is described. The ECL mechanism is based on the reaction between tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3)(2+)] and the tertiary amino group on amitriptyline. After optimizing the experimental conditions, a calibration over three orders of magnitude of concentration, was obtained. A linear calibration plot was constructed in order to evaluate the limit of detection, which was determined as 3.0 x 10(-7) mol l(-1) (94 ppb) with an average % S-r of 2.14 for 5 replicate measurements.
引用
收藏
页码:139 / 141
页数:3
相关论文
共 50 条
  • [21] Electrogenerated chemiluminescence sensor for the determination of propranolol hydrochloride
    Qi, Honglan
    Wang, Chen
    Zou, Rui
    Li, Libo
    ANALYTICAL METHODS, 2011, 3 (02) : 446 - 451
  • [22] Determination of phloroglucinol by flow injection electrogenerated chemiluminescence
    Guo, ZH
    Zheng, XW
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (04) : 461 - 463
  • [23] Electrogenerated Chemiluminescence
    Forster, Robert J.
    Bertoncello, Paolo
    Keyes, Tia E.
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2009, 2 : 359 - 385
  • [24] Flow injection chemiluminescence determination of catecholamines with electrogenerated hypochlorite
    Zhang, CX
    Huang, JC
    Zhang, ZJ
    Aizawa, MS
    ANALYTICA CHIMICA ACTA, 1998, 374 (01) : 105 - 110
  • [25] Flow injection chemiluminescence determination of etamsylate with electrogenerated hypochlorite
    Zhang, CX
    Huang, JC
    Feng, ML
    Zhang, ZJ
    ANALYTICAL LETTERS, 1998, 31 (11) : 1917 - 1928
  • [26] Flow injection chemiluminescence determination of isoniazid with electrogenerated hypochlorite
    Jiachu Huang
    Chengxiao Zhang
    Zhujun Zhang
    Fresenius' Journal of Analytical Chemistry, 1999, 363 : 126 - 128
  • [27] ELECTROGENERATED CHEMILUMINESCENCE
    VELASCO, JG
    BULLETIN OF ELECTROCHEMISTRY, 1994, 10 (01): : 29 - 38
  • [28] Flow injection chemiluminescence determination of isoniazid with electrogenerated hypochlorite
    Huang, JC
    Zhang, CX
    Zhang, ZJ
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (01): : 126 - 128
  • [29] Determination of fenoterol and salbutamol in pharmaceutical formulations by electrogenerated chemiluminescence
    Lindino, Cleber Antonio
    Bulhoes, Luis Otavio S.
    TALANTA, 2007, 72 (05) : 1746 - 1751
  • [30] A Simple Method for Determination of Chloroquine Based on Electrogenerated Chemiluminescence
    Pacheco, Jeovana C.
    Brito, Jhonathas A. R.
    dos Santos, Clenilton C.
    Bezerra, Cicero W. B.
    Damos, Flavio S.
    Luz, Rita C. S.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2023, 34 (10) : 1410 - 1419