Determination of amitriptyline using electrogenerated chemiluminescence

被引:18
|
作者
Dolman, SJL [1 ]
Greenway, GM [1 ]
机构
[1] UNIV HULL,SCH CHEM,KINGSTON HULL HU6 7RX,N HUMBERSIDE,ENGLAND
来源
ANALYTICAL COMMUNICATIONS | 1996年 / 33卷 / 04期
关键词
D O I
10.1039/ac9963300139
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method for the selective and sensitive determination of amitriptyline, a tricyclic antidepressant, using electrogenerated chemiluminescence (ECL) is described. The ECL mechanism is based on the reaction between tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3)(2+)] and the tertiary amino group on amitriptyline. After optimizing the experimental conditions, a calibration over three orders of magnitude of concentration, was obtained. A linear calibration plot was constructed in order to evaluate the limit of detection, which was determined as 3.0 x 10(-7) mol l(-1) (94 ppb) with an average % S-r of 2.14 for 5 replicate measurements.
引用
收藏
页码:139 / 141
页数:3
相关论文
共 50 条
  • [11] Flow-injection electrogenerated chemiluminescence determination of epinephrine using luminol
    Zheng, XW
    Guo, ZH
    Zhang, ZJ
    ANALYTICA CHIMICA ACTA, 2001, 441 (01) : 81 - 86
  • [12] Flow-injection electrogenerated chemiluminescence determination of isoniazid using luminol
    Zheng, XW
    Guo, ZH
    Zhang, ZJ
    ANALYTICAL SCIENCES, 2001, 17 (09) : 1095 - 1099
  • [13] Determination of norfloxacin using a terbium-sensitized electrogenerated chemiluminescence method
    Chen, SL
    Liu, Y
    Zhao, HC
    Jin, LP
    Zhang, ZL
    Zheng, YZ
    LUMINESCENCE, 2006, 21 (01) : 20 - 25
  • [14] Energy Transfer Electrogenerated Chemiluminescence for the Determination of Sulfite
    Meining Zhang
    Chengxiao Zhang
    Honglan Qi
    Microchimica Acta, 2004, 144 : 155 - 160
  • [15] Determination of norfloxacin by flow injection electrogenerated chemiluminescence
    Ma, HY
    Zheng, XW
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (07) : 857 - 860
  • [16] DETERMINATION OF OXALATE BY FIA WITH ELECTROGENERATED CHEMILUMINESCENCE DETECTION
    UCHIKURA, K
    BUNSEKI KAGAKU, 1990, 39 (06) : 323 - 326
  • [17] Electrogenerated chemiluminescence determination of some local anaesthetics
    Knight, AW
    Greenway, GM
    ANALYTICAL COMMUNICATIONS, 1996, 33 (05): : 171 - 174
  • [18] Sensitive Electrogenerated Chemiluminescence Sensor for Determination of Heroin
    Sun Bo
    Qi Hong-Lan
    Ling Chen
    Zhang Cui-Qin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (11) : 1601 - 1605
  • [19] Energy transfer electrogenerated chemiluminescence for the determination of sulfite
    Zhang, MN
    Zhang, CX
    Qi, HL
    MICROCHIMICA ACTA, 2004, 144 (1-3) : 155 - 160
  • [20] Homogeneous electrogenerated chemiluminescence immunoassay for the determination of digoxin
    Qi, HL
    Zhang, CX
    ANALYTICA CHIMICA ACTA, 2004, 501 (01) : 31 - 35