MR-guided stereotactic breast biopsy using a mixed ferromagnetic-nonmagnetic coaxial system with 12-to 18-gauge needles: clinical experience and long-term outcome

被引:0
作者
Belloni, Elena [1 ]
Panizza, Pietro [2 ]
Ravelli, Silvia [3 ]
De Cobelli, Francesco [3 ]
Gusmini, Simone [3 ]
Losio, Claudio [3 ]
Sassi, Isabella [4 ]
Perseghin, Gianluca [5 ]
Del Maschio, Alessandro [3 ]
机构
[1] Guglielmo da Saliceto Hosp, Dept Radiol, I-29100 Cantone Del Cristo, Piacenza, Italy
[2] Ist Tumori Fdn, Dept Radiol, Milan, Italy
[3] Univ Vita Salute San Raffaele, San Raffaele Sci Inst, Dept Radiol, Milan, Italy
[4] Univ Vita Salute San Raffaele, San Raffaele Sci Inst, Dept Pathol, Milan, Italy
[5] Univ Milan, Sport Nutr & Hlth Dept, Milan, Italy
来源
RADIOLOGIA MEDICA | 2013年 / 118卷 / 07期
关键词
Breast magnetic resonance; Breast lesion; Breast biopsy; Coaxial needle; Follow-up; INITIAL-EXPERIENCE; LESIONS; UNDERESTIMATION;
D O I
10.1007/s11547-013-0954-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study investigated the clinical application of a magnetic-resonance (MR)-guided breast biopsy (MRBB) system consisting of a nonmagnetic coaxial needle and a ferromagnetic core biopsy needle. MRBB was performed on 70 breast lesions. The biopsy device consisted of a nonmagnetic 14- to 16-gauge coaxial needle and a ferromagnetic 16- to 18-gauge biopsy needle. Of the 70 lesions, 29 were malignant and 41 nonmalignant. All 29 malignant lesions underwent surgery and were confirmed as malignant at final histology. Of the 41 nonmalignant lesions, 35 underwent follow-up breast MR imaging (mean, 26 +/- 19 months), which demonstrated no lesions changes; six lesions underwent surgery because of poor radiological-pathological correlation; of these 6 lesions, 3 were nonmalignant, one was borderline (lobular carcinoma in situ) and two were malignant (well-differentiated tubular carcinoma and infiltrating ductal carcinoma). Sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 93.5%, 100%, 100%, 95.1% and 97.1% if the lobular carcinoma in situ was considered a nonmalignant histological result, and 90.6%, 100%, 100%, 92.7% and 95.7% if the lobular carcinoma in situ was considered malignant. MRBB with a ferromagnetic-nonmagnetic coaxial system represented an easy way to perform a biopsy procedure and was easily applicable in the routine clinical setting.
引用
收藏
页码:1137 / 1148
页数:12
相关论文
共 20 条
  • [1] Anderson Benjamin O, 2006, J Natl Compr Canc Netw, V4, P511
  • [2] Utility of second-look ultrasound in the management of incidental enhancing lesions detected by breast MR imaging
    Carbognin, G.
    Girardi, V.
    Calciolari, C.
    Brandalise, A.
    Bonetti, F.
    Russo, A.
    Mucelli, R. Pozzi
    [J]. RADIOLOGIA MEDICA, 2010, 115 (08): : 1234 - 1245
  • [3] MRI-guided breast biopsy: Clinical experience with 14-gauge stainless steel core biopsy needle
    Chen, XM
    Lehman, CD
    Dee, KE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 1075 - 1080
  • [4] Interdisciplinary consensus on the uses and technique of MR-guided vacuum-assisted breast biopsy (VAB): Results of a European consensus meeting
    Heywang-Koebrunner, Sylvia H.
    Sinnatamby, Ruchi
    Lebeau, Annette
    Lebrecht, Antje
    Britton, Peter D.
    Schreer, Ingrid
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (02) : 289 - 294
  • [5] MR imaging-guided large-core (14-gauge) needle biopsy of small lesions visible at breast MR imaging alone
    Kuhl, CK
    Morakkabati, N
    Leutner, CC
    Schmiedel, A
    Wardelmann, E
    Schild, HH
    [J]. RADIOLOGY, 2001, 220 (01) : 31 - 39
  • [6] Kuhl KC, 1997, RADIOLOGY, V204, P667
  • [7] Underestimation of DCIS at MRI-Guided vacuum-assisted breast biopsy
    Lee, Jung-min
    Kaplan, Jennifer B.
    Murray, Melissa P.
    Mazur-Grbec, Marzena
    Tadic, Tade
    Stimac, Damir
    Liberman, Laura
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (02) : 468 - 474
  • [8] Clinical experience with MRI-guided vacuum-assisted breast biopsy
    Lehman, CD
    DePeri, ER
    Peacock, S
    McDonough, MD
    DeMartini, WB
    Shook, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (06) : 1782 - 1787
  • [9] MR imaging-guided breast biopsy using a coaxial technique with a 14-gauge stainless steel core biopsy needle and a titanium sheath
    Lehman, CD
    Eby, PR
    Chen, XM
    Dee, KE
    Thursten, B
    McCloskey, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (01) : 183 - 185
  • [10] MRI-guided 9-gauge vacuum-assisted breast biopsy: Initial clinical experience
    Liberman, L
    Bracero, N
    Morris, E
    Thornton, C
    Dershaw, DD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (01) : 183 - 193