Blood volume and cardiac index in rats after exchange transfusion with hemoglobin-based oxygen carriers

被引:64
作者
Migita, R
Gonzales, A
Gonzales, ML
Vandegriff, KD
Winslow, RM
机构
[1] VET ADM MED CTR,SAN DIEGO,CA 92161
[2] UNIV CALIF SAN DIEGO,SCH MED,DEPT MED,SAN DIEGO,CA 92103
关键词
hemoglobin; cardiac output; polyethylene glycol-modified hemoglobin; blood substitutes; colloid osmotic pressure; plasma volume; Evans blue dye; bovine hemoglobin;
D O I
10.1152/jappl.1997.82.6.1995
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We have measured plasma volume and cardiac index in rats after 50% isovolemic exchange transfusion with human hemoglobin cross-linked between the alpha-chains with bis(3,5-dibromosalicyl)fumarate (alpha alpha Hb) and with bovine hemoglobin modified with polyethylene glycol (PEGHb). alpha alpha Hb and PEGHb differ in colloid osmotic pressure (23.4 and 118.0 Torr, respectively), oxygen affinity (oxygen half-saturation pressure of hemoglobin = 30.0 and 10.2 Torr, respectively), viscosity (1.00 and 3.39 cP, respectively), and molecular weight (64,400 and 105,000, respectively). Plasma volume was measured by Evans blue dye dilution modified for interference by plasma hemoglobin. Blood volumes in PEGHb-treated animals were significantly elevated (74.0 +/- 3.5 ml/kg) compared with animals treated with alpha alpha Hb (49.0 +/- 1.2 ml/kg) or Ringer lactate (48.0 +/- 2.0 ml/kg) or with controls (58.2 +/- 1.9 ml/kg). Heart rate reduction after alpha alpha Hb exchange is opposite to that expected with lod volume contraction, suggesting that alpha alpha Hb may have a direct myocardial depressant action. The apparently slow elimination of PEGHb during the 2 h after its injection is a consequence of plasma volume expansion: when absolute hemoglobin (concentration x plasma volume) is compared for PEGHb and alpha alpha Hb, no difference in their elimination rates is found. These studies emphasize the need to understand blood volume regulation when the effects of cell-free hemoglobin on hemodynamic measurements are evaluated.
引用
收藏
页码:1995 / 2002
页数:8
相关论文
共 29 条
[21]   SIMULTANEOUS DETERMINATION OF PLASMA-VOLUME AND TRANSCAPILLARY ESCAPE RATE WITH I-131 LABELED ALBUMIN AND T-1824 IN NEWBORN [J].
PARVING, HH ;
KLEBE, JG ;
INGOMAR, CJ .
ACTA PAEDIATRICA SCANDINAVICA, 1973, 62 (03) :248-252
[22]  
PRZYBELSKI RJ, 1991, J LAB CLIN MED, V117, P143
[23]   EVALUATION OF A STROMA-FREE HEMOGLOBIN SOLUTION FOR USE AS A PLASMA EXPANDER [J].
RABINER, SF ;
HELBERT, JR ;
LOPAS, H ;
FRIEDMAN, LH .
JOURNAL OF EXPERIMENTAL MEDICINE, 1967, 126 (06) :1127-+
[24]   COLLOID OSMOTIC-PRESSURE OF PLASMA REPLACEMENT FLUIDS [J].
TONNESSEN, T ;
TOLLOFSRUD, S ;
KONGSGAARD, UE ;
NODDELAND, H .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1993, 37 (04) :424-426
[25]   FLUID PARTITION AND CARDIAC-OUTPUT IN VOLUME-DEPLETED GOLDBLATT HYPERTENSIVE RATS [J].
TRIPPODO, NC ;
WALSH, GM ;
FERRONE, RA ;
DUGAN, RC .
AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 237 (01) :H18-H24
[26]  
Tsai Amy G., 1996, P124
[27]   MEASUREMENT OF CIRCULATING BLOOD-VOLUME IN-VIVO AFTER TRAUMA-HEMORRHAGE AND HEMODILUTION [J].
WANG, P ;
BA, ZF ;
LU, MC ;
AYALA, A ;
HARKEMA, JM ;
CHAUDRY, IH .
AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 266 (02) :R368-R374
[28]  
Winslow R.M, 1992, HEMOGLOBIN BASED RED
[29]  
WINSLOW RM, 1994, METHOD ENZYMOL, V231, P3