Development, Validation, and Application of a Portable SPR Biosensor for the Direct Detection of Insecticide Residues

被引:1
|
作者
Yang, Gilmo [1 ]
Cho, Nam-Hong [1 ]
机构
[1] Rural Dev Adm, Natl Inst Agr Engn, Suwon 441100, Gyeonggi, South Korea
关键词
Surface plasmon resonance; biosensor; insecticide; pesticide; carbamate; organophosphate;
D O I
暂无
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
This Study was carried out to develop a small-sized biosensor based on Surface plasmon resonance (SPR) for the rapid identification of insecticide residues for food safety. The SPR biosensor module Consists of a single 770 rim-fight emitting diodes (LED) light source, several optical lenses for transferring light, a hemisphere sensor chip, photo detector, A/D converter, power Source, and software for signal processing using a computer. Except for the computer, the size and weight of the sensor module are 150 (L)x70 (W)x120 (H) mm and 828 g, respectively. Validation and application procedures were designed to assess refractive index analysis, affinity properties, sensitivity, linearity, limits of detection, and robustness which includes an analysis of baseline stability and reproducibility of ligand immobilization using carbamate (carbofuran and carbaryl) and organophosphate (cadusafos, ethoprofos, and chlorpyrifos) insecticide residues. With direct binding analysis, insecticide residues were detected at less than the minimum 0.01 ppm and analyzed in less than 100 sec with a good linear relationship. Based on these results, we find that the binding interaction with active target groups in enzymes using the miniaturized SPR biosensor could detect low concentrations which satisfy, the maximum residue limits for pesticide tolerance in Korea, Japan, and the USA.
引用
收藏
页码:1038 / 1046
页数:9
相关论文
共 30 条
  • [21] The development and validation of a sensitive, dual-flow cell, SPR-based biosensor immunoassay for the detection, semi-quantitation, and characterization of antibodies to darbepoetin alfa and epoetin alfa in human serum
    Mytych, Daniel T.
    La, Stephon
    Barger, Troy
    Ferbas, John
    Swanson, Steven J.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (02) : 415 - 426
  • [22] The development of a new biosensor based on recombinant E-coli for the direct detection of organophosphorus neurotoxins
    Rainina, EI
    Efremenco, EN
    Varfolomeyev, SD
    Simonian, AL
    Wild, JR
    BIOSENSORS & BIOELECTRONICS, 1996, 11 (10) : 991 - 1000
  • [23] Immobilization of Bovine Serum Albumin on Polytetrafluoroethylene for Application as a Potential Solid Support for Biosensor Development with Visual Detection
    Magiati, Maria
    Kyriakopoulou, Christina I.
    Kalogianni, Despina P.
    ANALYTICAL LETTERS, 2018, 51 (13) : 2050 - 2061
  • [24] Development of acetylcholinesterase silica sol-gel immobilized biosensor - an application towards oxydemeton methyl detection
    Anitha, K
    Mohan, SV
    Reddy, SJ
    BIOSENSORS & BIOELECTRONICS, 2004, 20 (04) : 848 - 856
  • [25] Development and validation of a potentiometric biosensor assay for tylosin with demonstrated applicability for the detection of two other antimicrobial growth-promoter compounds in feedstuffs
    Stead, S. L.
    Wolodko-Cierniak, K. B.
    Richmond, S. F.
    Sharman, M.
    Driver, P.
    Teale, P.
    Leonardova, O.
    Purvis, D.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2011, 28 (07): : 848 - 859
  • [26] Development and kinetic validation of an assay for the quantitative determination of peroxidase: Application in the detection of activity in crude plant tissues
    Shivakumar, Anantharaman
    Rangappa, Dinesh
    Krishna, Honnur
    Nagaraja, Padmarajaiah
    ENZYME AND MICROBIAL TECHNOLOGY, 2010, 47 (06) : 243 - 248
  • [27] Development and Validation of a Simple and Rapid HPLC Method for the Evaluation of Pesticide Residues in Plasma Samples of Farmers; Application in Toxicological and Risk Assessment Studies
    Farajzadeh, Mir Ali
    Mohebbi, Ali
    Mogaddam, Mohammad Reza Afshar
    PHARMACEUTICAL SCIENCES, 2020, 26 (03) : 332 - 337
  • [28] Two birds with one stone: A universal design and application of signal-on labeled fluorescent/electrochemical dual-signal mode biosensor for the detection of tetracycline residues in tap water, milk and chicken
    Yang, Lanqing
    Wang, Xiaomin
    Zhang, Fuyuan
    Yu, Ligang
    Bai, Baoqing
    Zhang, Jinhua
    Zhang, Bo
    Tian, Yu
    Qin, Shu
    Yang, Yukun
    FOOD CHEMISTRY, 2024, 430
  • [29] Detection of 11 carbamate pesticide residues in raw and pasteurized camel milk samples using liquid chromatography tandem mass spectrometry: Method development, method validation, and health risk assessment
    Morsi, Rana
    Ghoudi, Kilani
    Ayyash, Mutamed M.
    Jiang, Xiue
    Meetani, Mohammed A.
    JOURNAL OF DAIRY SCIENCE, 2024, 107 (04) : 1916 - 1927
  • [30] Development, validation and application of a methodology based on solid-phase micro extraction followed by gas chromatography coupled to mass spectrometry (SPME/GC-MS) for the determination of pesticide residues in mangoes
    Menezes Filho, Adalberto
    dos Santos, Fabio Neves
    de Paula Pereira, Pedro Afonso
    TALANTA, 2010, 81 (1-2) : 346 - 354