Analysis and prediction of daylighting and energy performance in atrium spaces using daylight-linked lighting controls

被引:65
作者
Chow, Stanley K. H. [1 ]
Li, Danny H. W. [1 ]
Lee, Eric W. M. [1 ]
Lam, Joseph C. [1 ]
机构
[1] City Univ Hong Kong, Dept Civil & Architectural Engn, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R China
关键词
Atrium; Daylight; Greenhouse gases; Daylight-linked lighting controls; Energy savings; NEW-DELHI; ILLUMINANCE; BUILDINGS; SAVINGS; CORRIDOR; MODEL;
D O I
10.1016/j.apenergy.2012.12.033
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In subtropical Hong Kong, a certain amount of electricity is used to create visually comfortable interior spaces through electric lighting, which is the second major electricity-consuming item in commercial buildings, accounting for 20-30% of total electricity use. The burning of fossil fuels for electricity generation has many adverse effects on the environment. Daylighting is an important and useful strategy for enhancing visual comfort and reducing the need for the electricity consumed by light fittings. The rational use of daylight through tools such as photoelectric lighting controls can effectively reduce buildings' electricity consumption and the related pollutants and greenhouse gas emissions. Daylighting design techniques are often best demonstrated via field measurements that provide reliable operational and energy performance data for establishing design guidelines. An atrium provides an environmentally controlled indoor public space that introduces daylight into the hearts of large buildings. In circulation areas such as corridors, people expect the way ahead to be sufficiently lit and daylight-linked lighting controls can deliver excellent energy savings. This paper presents the daylighting and energy performance of an atrium space using daylight-linked lighting controls. The cost, energy and environmental issues related to various daylight illuminances are estimated and design implications are discussed. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1016 / 1024
页数:9
相关论文
共 34 条
[1]  
Aizlewood ME, 1995, ASHRAE TRAN, V101, P841
[2]  
Atif MR., 1997, Daylighting Monitoring Protocols Procedures for Buildings, a Report of Task 21/Annex 29 Daylight in Buildings
[3]  
Beker N, 1993, DAYLIGHTING ARCHITEC
[4]  
British Standards Institution, 1992, BS8206 BSI 2
[5]   Daylight factor prediction in atria building designs [J].
Calcagni, B ;
Paroncini, M .
SOLAR ENERGY, 2004, 76 (06) :669-682
[6]  
*CHART I BUILD SER, 1994, CIBSE COD INT LIGHT
[7]   A modified model for estimation of daylight factor for skylight integrated with dome roof structure of mud-house in New Delhi (India) [J].
Chel, Arvind ;
Tiwari, G. N. ;
Singh, H. N. .
APPLIED ENERGY, 2010, 87 (10) :3037-3050
[8]   The role of spectral response of photosensors in daylight responsive systems [J].
Doulos, L. ;
Tsangrassoulis, A. ;
Topalis, F. V. .
ENERGY AND BUILDINGS, 2008, 40 (04) :588-599
[9]  
Electrical and Mechanical Services Department, 2009, HONG KONG EN END US
[10]  
Electrical and Mechanical Services Department, 2007, COD PRACT EN EFF LIG