Operation modeling of closed-end and closed-loop oscillating heat pipes at normal operating condition

被引:56
|
作者
Sakulchangsatjatai, P [1 ]
Terdtoon, P
Wongratanaphisan, T
Kamonpet, P
Murakami, M
机构
[1] Chiang Mai Univ, Dept Engn Mech, Fac Engn, Chiang Mai 50200, Thailand
[2] Univ Tsukuba, Inst Mech Engn & Syst, Tsukuba, Ibaraki 305, Japan
关键词
closed-end oscillating heat pipe; top heat mode; heat transfer characteristics;
D O I
10.1016/j.applthermaleng.2003.11.006
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat transfer characteristics of a closed-end oscillating heat pipe (CEOHP) and a closed-loop oscillating heat pipe (CLOHP) at normal operating condition were modeled using the explicit finite element method. The parameters affecting the heat transfer of a CEOHP and a CLOHP at top heat mode were analytically investigated. The principles and theories of internal friction flow, basic governing equations and a finite difference scheme were applied to evaluate the heat transfer rate. The predicted heat transfer rate, obtained from the model, was compared to the existing experimental data. The effects of the working fluid, evaporator length and inner diameter on the performance of a CEOHP and a CLOHP were also investigated. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:995 / 1008
页数:14
相关论文
共 50 条
  • [21] Assessment of operation of an underground closed-loop geothermal heat exchanger
    W. Nowak
    A. A. Stachel
    Journal of Engineering Physics and Thermophysics, 2005, 78 (1) : 136 - 143
  • [22] Experimental study of the performance of a solar collector by closed-end oscillating heat pipe (CEOHP)
    Rittidech, S.
    Wannapakne, S.
    APPLIED THERMAL ENGINEERING, 2007, 27 (11-12) : 1978 - 1985
  • [23] Modeling and optimal operation of batch closed-loop diafiltration processes
    Sharma, Ayush
    Jelemensky, Martin
    Paulen, Radoslav
    Fikar, Miroslav
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 122 : 198 - 210
  • [24] Closed-Loop Systems for the Operation Room (OR)
    Stallkamp, J.
    ENDOSKOPIE HEUTE, 2011, 24 (04) : 248 - 251
  • [25] Closed-loop identification condition for ARMAX models using routine operating data
    Shardt, Yuri A. W.
    Huang, Biao
    AUTOMATICA, 2011, 47 (07) : 1534 - 1537
  • [26] Closed-loop pulsating heat pipe
    Tong, BY
    Wong, TN
    Ooi, KT
    APPLIED THERMAL ENGINEERING, 2001, 21 (18) : 1845 - 1862
  • [27] CLOSED-LOOP COOLING SYSTEM ELIMINATES CLOGGED PIPES
    不详
    RUBBER AGE, 1970, 102 (04): : 65 - &
  • [28] Operating characteristics of open and closed-end gas electron multipliers
    Cho, HS
    Yoon, H
    Han, SH
    Kim, H
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2003, 42 (01) : 56 - 59
  • [29] Motion and Heat-Transfer Analysis of a Closed-Loop Oscillating Heat Pipe with a Magnetic Field
    Wongkasem, K.
    Rittidech, S.
    Bubphachot, B.
    JOURNAL OF ENHANCED HEAT TRANSFER, 2010, 17 (04) : 369 - 380
  • [30] Experimental study of flow state and heat transfer performance of closed-loop oscillating heat pipe
    Liu, Xiang-Dong
    Shi, Kai
    Guo, Yu-Han
    Lu, Jin-Li
    Wang, Shu-Juan
    Hao, Ying-Li
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (10): : 1735 - 1738