High early revision rate with the FPV patello-femoral unicompartmental arthroplasty

被引:16
|
作者
Davies, Andrew P. [1 ]
机构
[1] Morriston Hosp, Swansea SA6 6NL, W Glam, Wales
关键词
Patellofemoral; Arthroplasty; Unicompartmental; Revision; FPV; KNEE ARTHROPLASTY; REPLACEMENT;
D O I
10.1016/j.knee.2013.07.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Unicompartmental patellofemoral arthroplasties are uncommon however numbers are increasing and there are a variety of new prostheses available. The Femoro-Patella Vialla (FPV, Wright Medical) device was the second most commonly used patellofemoral unicompartmental prosthesis in the 2012 British National Joint Register. There are however no published outcomes data for this device. Method: 52 consecutive cases were studied prospectively using Oxford Knee Score and American Knee Society Scores pre-operatively and at follow up to a minimum of two years. Results: Overall Oxford Knee Scores improved from 30 points pre-operatively (36.6%) to 19 points (60%) at one-year. American Knee Society Knee scores improved from 51 points pre-operatively to 81 points atone-year. Function scores improved from 42 points pre-operatively to 70 points at one-year. 13 (25%) patients had an excellent outcome with pain abolished and near normal knee function. 11(21%) patients gained very little improvement and scored their knees similar or worse to their pre-operative state. There were no infective or thromboembolic complications. Seven cases have been revised to a total knee replacement for on-going pain in six cases and progression of arthritis in the tibio-femoral compartments in one case. The patellar button was found to be very poorly fixed in all cases that were revised. Conclusion: Early results with the FPV prosthesis demonstrate that successful outcomes can be achieved however the results were unpredictable and a significant minority of patients had on-going symptoms that they found unacceptable. The early revision rate was high in this series. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:482 / 484
页数:3
相关论文
共 50 条
  • [41] Two-Stage Revision of Total Hip Arthroplasty for Infection Is Associated with a High Rate of Dislocation
    McAlister, Ian P.
    Perry, Kevin I.
    Mara, Kristin C.
    Hanssen, Arlen D.
    Berry, Daniel J.
    Abdel, Matthew P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (04) : 322 - 329
  • [42] Choice of approach, but not femoral head size, affects revision rate due to dislocations in THA after femoral neck fracture: results from the Lithuanian Arthroplasty Register
    Algimantas Cebatorius
    Otto Robertsson
    Justinas Stucinskas
    Alfredas Smailys
    Linas Leonas
    Sarunas Tarasevicius
    International Orthopaedics, 2015, 39 : 1073 - 1076
  • [43] High revision rates and mortality after distal femoral replacement for periprosthetic distal femoral fractures: analysis from the German Arthroplasty Registry (EPRD)
    Luetzner, Joerg
    Melsheimer, Oliver
    Steinbrueck, Arnd
    Postler, Anne Elisabeth
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (01) : 331 - 338
  • [44] High return to sport rate in patients undergoing image-based robotic arm assisted unicompartmental knee arthroplasty
    Daffara, Valerio
    Zambianchi, Francesco
    Festa, Enrico
    Costantini, Riccardo Cuoghi
    Clemenza, Sebastiano
    Catani, Fabio
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (09) : 4037 - 4044
  • [45] High revision rate of metal-backed glenoid component and impact on the overall revision rate of stemless total shoul-der arthroplasty: a cohort study from the Danish Shoulder Arthroplasty Registry
    Nyring, Marc R. K.
    Olsen, Bo S.
    Jensen, Steen L.
    Rasmussen, Jeppe, V
    ACTA ORTHOPAEDICA, 2024, 95 : 386 - 391
  • [46] Early failure of revision total hip arthroplasty with cemented precoated femoral components - Comparison with uncemented components at 2 to 8 years
    Schmale, GA
    Lachiewicz, PF
    Kelley, SS
    JOURNAL OF ARTHROPLASTY, 2000, 15 (06) : 718 - 729
  • [47] High Rate of Re-Revision in Patients Less Than 55 Years of Age Undergoing Aseptic Revision Total Knee Arthroplasty
    Chalmers, Brian P.
    Syku, Marie
    Joseph, Amethia D.
    Mayman, David J.
    Haas, Steve B.
    Blevins, Jason L.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (07) : 2348 - 2352
  • [48] Cementing technique affects the rate of femoral component loosening after high flexion total knee arthroplasty
    Han, Hyuk-Soo
    Lee, Myung Chul
    KNEE, 2017, 24 (06) : 1435 - 1441
  • [49] Rate of complications and short-term Functional Results of Revision Total Knee Arthroplasty for Tibio-femoral Instability: do stability and range of motion are restored in 62 revisions
    Labouyrie, Antoine
    Artus, Julien
    Putman, Sophie
    Trouillez, Teddy
    Migaud, Henri
    Asquier, Gilles P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2025, 111 (01)
  • [50] High Survival Rate and Very Low Wear of Lateral Unicompartmental Arthroplasty at Long Term A Case Series of 54 Cases at a Mean Follow-Up of 17 Years
    Deroche, Etienne
    Batailler, Cecile
    Lording, Timothy
    Neyret, Philippe
    Servien, Elvire
    Lustig, Sebastien
    JOURNAL OF ARTHROPLASTY, 2019, 34 (06) : 1097 - 1104