Evaluation of proton inelastic reaction models in Geant4 for prompt gamma production during proton radiotherapy

被引:16
|
作者
Jeyasugiththan, Jeyasingam [1 ,2 ]
Peterson, Stephen W. [1 ]
机构
[1] Univ Cape Town, Dept Phys, ZA-7701 Rondebosch, South Africa
[2] Teaching Hosp, Dept Clin Oncol, Jaffna, Sri Lanka
关键词
prompt gamma; Geant4; cross section; proton beam radiotherapy; CROSS-SECTIONS RELEVANT; RANGE VERIFICATION; COMPTON CAMERA; SIMULATION; THERAPY; RAYS; SCATTERING; ASTRONOMY; O-16; C-12;
D O I
10.1088/0031-9155/60/19/7617
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During proton beam radiotherapy, discrete secondary prompt gamma rays are induced by inelastic nuclear reactions between protons and nuclei in the human body. In recent years, the Geant4 Monte Carlo toolkit has played an important role in the development of a device for real time dose range verification purposes using prompt gamma radiation. Unfortunately the default physics models in Geant4 do not reliably replicate the measured prompt gamma emission. Determining a suitable physics model for low energy proton inelastic interactions will boost the accuracy of prompt gamma simulations. Among the built-in physics models, we found that the precompound model with a modified initial exciton state of 2 (1 particle, 1 hole) produced more accurate discrete gamma lines from the most important elements found within the body such as O-16, C-12 and N-14 when comparing them with the available gamma production cross section data. Using the modified physics model, we investigated the prompt gamma spectra produced in a water phantom by a 200 MeV pencil beam of protons. The spectra were attained using a LaBr3 detector with a time-of-flight (TOF) window and BGO active shield to reduce the secondary neutron and gamma background. The simulations show that a 2 ns TOF window could reduce 99% of the secondary neutron flux hitting the detector. The results show that using both timing and active shielding can remove up to 85% of the background radiation which includes a 33% reduction by BGO subtraction.
引用
收藏
页码:7617 / 7635
页数:19
相关论文
共 50 条
  • [41] Anti-proton contamination design of the imaging energetic electron spectrometer based on Geant4 simulation
    LUO Lin
    ZOU Hong
    ZONG QiuGang
    WANG LingHua
    CHEN HongFei
    SHI WeiHong
    YU XiangQian
    Science China(Technological Sciences), 2015, (08) : 1385 - 1391
  • [42] Dependence of the Depth-Dose Distributions and Ranges of Proton Beams in Water Medium on Geant4 Parameters
    Tok, A.
    Bektasoglu, M.
    Arslan, H.
    ACTA PHYSICA POLONICA A, 2016, 130 (01) : 438 - 440
  • [43] Monte Carlo calculation of beam quality correction factors in proton beams using TOPAS/GEANT4
    Baumann, Kilian-Simon
    Kaupa, Sina
    Bach, Constantin
    Engenhart-Cabillic, Rita
    Zink, Klemens
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05)
  • [44] Anti-proton contamination design of the imaging energetic electron spectrometer based on Geant4 simulation
    Luo Lin
    Zou Hong
    Zong QiuGang
    Wang LingHua
    Chen HongFei
    Shi WeiHong
    Yu XiangQian
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2015, 58 (08) : 1385 - 1391
  • [45] Deep residual fully connected neural network classification of Compton camera based prompt gamma imaging for proton radiotherapy
    Barajas, Carlos A. A.
    Polf, Jerimy C. C.
    Gobbert, Matthias K. K.
    FRONTIERS IN PHYSICS, 2023, 11
  • [46] A triple-imaging-modality system for simultaneous measurements of prompt gamma photons, prompt x-rays, and induced positrons during proton beam irradiation
    Yamamoto, Seiichi
    Watabe, Hiroshi
    Nakanishi, Kohei
    Yabe, Takuya
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Kamada, Kei
    Yoshikawa, Akira
    Miyake, Masayasu
    Tanaka, Kazuo S.
    Kataoka, Jun
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (05)
  • [47] Computational model for detector timing effects in Compton-camera based prompt-gamma imaging for proton radiotherapy
    Maggi, Paul
    Peterson, Steve
    Panthi, Rajesh
    Mackin, Dennis
    Yang, Hao
    He, Zhong
    Beddar, Sam
    Polf, Jerimy
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (12)
  • [48] A comparison of X-ray and proton beam low energy secondary electron track structures using the low energy models of Geant4
    McNamara, Aimee L.
    Guatelli, Susanna
    Prokopovich, Dale A.
    Reinhard, Mark I.
    Rosenfeld, Anatoly B.
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2012, 88 (1-2) : 164 - 170
  • [49] Evaluation of a Novel Multi-slit Collimated Detection System for Prompt Gamma-Ray Imaging During Proton Beam Therapy
    Ellin, J.
    Ready, J.
    Negut, V
    Pak, R.
    Haefner, A.
    Mihailescu, L.
    Vetter, K.
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [50] Material efficiency studies for a Compton camera designed to measure characteristic prompt gamma rays emitted during proton beam radiotherapy
    Robertson, Daniel
    Polf, Jerimy C.
    Peterson, Steve W.
    Gillin, Michael T.
    Beddar, Sam
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (10) : 3047 - 3059