Evaluation of proton inelastic reaction models in Geant4 for prompt gamma production during proton radiotherapy

被引:16
|
作者
Jeyasugiththan, Jeyasingam [1 ,2 ]
Peterson, Stephen W. [1 ]
机构
[1] Univ Cape Town, Dept Phys, ZA-7701 Rondebosch, South Africa
[2] Teaching Hosp, Dept Clin Oncol, Jaffna, Sri Lanka
关键词
prompt gamma; Geant4; cross section; proton beam radiotherapy; CROSS-SECTIONS RELEVANT; RANGE VERIFICATION; COMPTON CAMERA; SIMULATION; THERAPY; RAYS; SCATTERING; ASTRONOMY; O-16; C-12;
D O I
10.1088/0031-9155/60/19/7617
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During proton beam radiotherapy, discrete secondary prompt gamma rays are induced by inelastic nuclear reactions between protons and nuclei in the human body. In recent years, the Geant4 Monte Carlo toolkit has played an important role in the development of a device for real time dose range verification purposes using prompt gamma radiation. Unfortunately the default physics models in Geant4 do not reliably replicate the measured prompt gamma emission. Determining a suitable physics model for low energy proton inelastic interactions will boost the accuracy of prompt gamma simulations. Among the built-in physics models, we found that the precompound model with a modified initial exciton state of 2 (1 particle, 1 hole) produced more accurate discrete gamma lines from the most important elements found within the body such as O-16, C-12 and N-14 when comparing them with the available gamma production cross section data. Using the modified physics model, we investigated the prompt gamma spectra produced in a water phantom by a 200 MeV pencil beam of protons. The spectra were attained using a LaBr3 detector with a time-of-flight (TOF) window and BGO active shield to reduce the secondary neutron and gamma background. The simulations show that a 2 ns TOF window could reduce 99% of the secondary neutron flux hitting the detector. The results show that using both timing and active shielding can remove up to 85% of the background radiation which includes a 33% reduction by BGO subtraction.
引用
收藏
页码:7617 / 7635
页数:19
相关论文
共 50 条
  • [31] Detecting prompt gamma emission during proton therapy: the effects of detector size and distance from the patient
    Polf, Jerimy C.
    Mackin, Dennis
    Lee, Eunsin
    Avery, Stephen
    Beddar, Sam
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (09) : 2325 - 2340
  • [32] Optimizing a three-stage Compton camera for measuring prompt gamma rays emitted during proton radiotherapy
    Peterson, S. W.
    Robertson, D.
    Polf, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (22) : 6841 - 6856
  • [33] PRELIMINARY STUDY OF PROTON RADIOGRAPHY IMAGING QUALITIES USING GEANT4 MONTE CARLO SIMULATIONS
    Depauw, Nicolas
    Danto, Sylvain
    Bednarz, Bryan
    Paganetti, Harald
    Fink, Yoel
    Seco, Joao
    NUCLEAR TECHNOLOGY, 2011, 175 (01) : 6 - 10
  • [34] Simulation and experimental verification of prompt gamma-ray emissions during proton irradiation
    Schumann, A.
    Petzoldt, J.
    Dendooven, P.
    Enghardt, W.
    Golnik, C.
    Hueso-Gonzalez, F.
    Kormoll, T.
    Pausch, G.
    Roemer, K.
    Fiedler, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (10) : 4197 - 4207
  • [35] The effects of mapping CT images to Monte Carlo materials on GEANT4 proton simulation accuracy
    Barnes, Samuel
    McAuley, Grant
    Slater, James
    Wroe, Andrew
    MEDICAL PHYSICS, 2013, 40 (04)
  • [36] Simulation of spread-out bragg peaks in proton beams using Geant4/TOPAS
    Velten, Christian
    Tome, Wolfgang A.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (04):
  • [37] Investigation of the effects of the step size of Geant4 electromagnetic physics on the depth dose simulation of a small field proton beam
    Balaji, Selvaraj
    Lee, Chung-Chi
    Aso, Tsukasa
    Wu, Tung-Ho
    Chiang, Yueh
    Luu Dang Hoang Oanh
    Tseng, Chien-Kai
    Chen, Chia-Ray
    Chao, Tsi-Chian
    RADIATION PHYSICS AND CHEMISTRY, 2022, 195
  • [38] Geant4 Simulation Study of Dose Distribution and Energy Straggling for Proton and Carbon Ion Beams in Water
    Zhao, Qiang
    Zhang, Zheng
    Li, Yang
    2016 THE INTERNATIONAL CONFERENCE ON NANOMATERIAL, SEMICONDUCTOR AND COMPOSITE MATERIALS (ICNSCM 2016), 2016, 65
  • [39] Comparative study of alternative Geant4 hadronic ion inelastic physics models for prediction of positron-emitting radionuclide production in carbon and oxygen ion therapy
    Chacon, Andrew
    Guatelli, Susanna
    Rutherford, Harley
    Bolst, David
    Mohammadi, Akram
    Ahmed, Abdella
    Nitta, Munetaka
    Nishikido, Fumihiko
    Iwao, Yuma
    Tashima, Hideaki
    Yoshida, Eiji
    Akamatsu, Go
    Takyu, Sodai
    Kitagawa, Atsushi
    Hofmann, Theresa
    Pinto, Marco
    Franklin, Daniel R.
    Parodi, Katia
    Yamaya, Taiga
    Rosenfeld, Anatoly
    Safavi-Naeini, Mitra
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (15)
  • [40] A Geant4 based simulation platform of the HollandPTC R&D proton beamline for radiobiological studies
    Groenendijk, Celebrity F.
    Rovituso, Marta
    Lathouwers, Danny
    Brown, Jeremy M. C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 112