Evaluation of proton inelastic reaction models in Geant4 for prompt gamma production during proton radiotherapy

被引:16
|
作者
Jeyasugiththan, Jeyasingam [1 ,2 ]
Peterson, Stephen W. [1 ]
机构
[1] Univ Cape Town, Dept Phys, ZA-7701 Rondebosch, South Africa
[2] Teaching Hosp, Dept Clin Oncol, Jaffna, Sri Lanka
关键词
prompt gamma; Geant4; cross section; proton beam radiotherapy; CROSS-SECTIONS RELEVANT; RANGE VERIFICATION; COMPTON CAMERA; SIMULATION; THERAPY; RAYS; SCATTERING; ASTRONOMY; O-16; C-12;
D O I
10.1088/0031-9155/60/19/7617
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During proton beam radiotherapy, discrete secondary prompt gamma rays are induced by inelastic nuclear reactions between protons and nuclei in the human body. In recent years, the Geant4 Monte Carlo toolkit has played an important role in the development of a device for real time dose range verification purposes using prompt gamma radiation. Unfortunately the default physics models in Geant4 do not reliably replicate the measured prompt gamma emission. Determining a suitable physics model for low energy proton inelastic interactions will boost the accuracy of prompt gamma simulations. Among the built-in physics models, we found that the precompound model with a modified initial exciton state of 2 (1 particle, 1 hole) produced more accurate discrete gamma lines from the most important elements found within the body such as O-16, C-12 and N-14 when comparing them with the available gamma production cross section data. Using the modified physics model, we investigated the prompt gamma spectra produced in a water phantom by a 200 MeV pencil beam of protons. The spectra were attained using a LaBr3 detector with a time-of-flight (TOF) window and BGO active shield to reduce the secondary neutron and gamma background. The simulations show that a 2 ns TOF window could reduce 99% of the secondary neutron flux hitting the detector. The results show that using both timing and active shielding can remove up to 85% of the background radiation which includes a 33% reduction by BGO subtraction.
引用
收藏
页码:7617 / 7635
页数:19
相关论文
共 50 条
  • [21] A Geant4 simulation for three-dimensional proton imaging of microscopic samples
    Michelet, Claire
    Li, Zhuxin
    Yang, Wen
    Incerti, Sebastien
    Desbarats, Pascal
    Giovannelli, Jean-Francois
    Barberet, Philippe
    Delville, Marie-Helene
    Gordillo, Nuria
    Deves, Guillaume
    Seznec, Herve
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 172 - 180
  • [22] Classification of Compton Camera Based Prompt Gamma Imaging for Proton Radiotherapy by Random Forests
    Barajas, Carlos A.
    Kroiz, Gerson C.
    Gobbert, Matthias K.
    Polf, Jerimy C.
    2021 INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE AND COMPUTATIONAL INTELLIGENCE (CSCI 2021), 2021, : 308 - 311
  • [23] Measurement of prompt gamma profiles in inhomogeneous targets with a knife-edge slit camera during proton irradiation
    Priegnitz, M.
    Helmbrecht, S.
    Janssens, G.
    Perali, I.
    Smeets, J.
    Stappen, F. Vander
    Sterpin, E.
    Fiedler, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (12) : 4849 - 4871
  • [24] Estimation of respiratory phases during proton radiotherapy from a 4D-CT and Prompt gamma detection profiles
    Albert, Jaroslav
    Labarbe, Rudi
    Janssens, Guillaume
    Souris, Kevin
    Sterpin, Edmond
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 33 - 39
  • [25] A multi-source based Monte Carlo simulation model for spot scanning proton radiotherapy using GEANT4
    Galanakou, Panagiota
    String, Shawn
    Shang, Charles
    Tahir, Sajjad
    Aydogan, Bulent
    Muhammad, Wazir
    RADIATION PHYSICS AND CHEMISTRY, 2023, 208
  • [26] Optimization of a general-purpose, actively scanned proton beamline for ocular treatments: Geant4 simulations
    Piersimoni, Pierluigi
    Rimoldi, Adele
    Riccardi, Cristina
    Pirola, Michele
    Molinelli, Silvia
    Ciocca, Mario
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (02): : 261 - 278
  • [27] Measuring Prompt Gamma Ray Emission During Proton Radiotherapy For Assessment Of Treatment Delivery And Patient Response
    Polf, Jerimy C.
    Peterson, Stephen
    Robertson, Daniel
    Beddar, Sam
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY: TWENTY-FIRST INTERNATIONAL CONFERENCE, 2011, 1336 : 364 - 368
  • [28] Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit
    Kim, Dae-Hyun
    Kang, Young Nam
    Suh, Tae-Suk
    Shin, Jungwook
    Kim, Jong Won
    Yoo, Seung Hoon
    Park, Seyjoon
    Lee, Sang Hoon
    Cho, Sungkoo
    Shin, Dongho
    Kim, Dae Yong
    Lee, Se Byeong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (07) : 1125 - 1130
  • [29] Comparing Geant4 physics models for proton-induced dose deposition and radiolysis enhancement from a gold nanoparticle
    Rajabpour, Saeed
    Saberi, Hassan
    Rasouli, Javad
    Jabbari, Nasrollah
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [30] Monte Carlo simulation of secondary gamma production during proton therapy for dose verification purposes
    Jeyasugiththan, Jeyasingam
    Peterson, Stephen
    PROCEEDINGS OF SAIP2014: THE 59TH ANNUAL CONFERENCE OF THE SOUTH AFRICAN INSTITUTE OF PHYSICS, 2014, : 192 - 198