Evaluation of proton inelastic reaction models in Geant4 for prompt gamma production during proton radiotherapy

被引:16
|
作者
Jeyasugiththan, Jeyasingam [1 ,2 ]
Peterson, Stephen W. [1 ]
机构
[1] Univ Cape Town, Dept Phys, ZA-7701 Rondebosch, South Africa
[2] Teaching Hosp, Dept Clin Oncol, Jaffna, Sri Lanka
关键词
prompt gamma; Geant4; cross section; proton beam radiotherapy; CROSS-SECTIONS RELEVANT; RANGE VERIFICATION; COMPTON CAMERA; SIMULATION; THERAPY; RAYS; SCATTERING; ASTRONOMY; O-16; C-12;
D O I
10.1088/0031-9155/60/19/7617
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During proton beam radiotherapy, discrete secondary prompt gamma rays are induced by inelastic nuclear reactions between protons and nuclei in the human body. In recent years, the Geant4 Monte Carlo toolkit has played an important role in the development of a device for real time dose range verification purposes using prompt gamma radiation. Unfortunately the default physics models in Geant4 do not reliably replicate the measured prompt gamma emission. Determining a suitable physics model for low energy proton inelastic interactions will boost the accuracy of prompt gamma simulations. Among the built-in physics models, we found that the precompound model with a modified initial exciton state of 2 (1 particle, 1 hole) produced more accurate discrete gamma lines from the most important elements found within the body such as O-16, C-12 and N-14 when comparing them with the available gamma production cross section data. Using the modified physics model, we investigated the prompt gamma spectra produced in a water phantom by a 200 MeV pencil beam of protons. The spectra were attained using a LaBr3 detector with a time-of-flight (TOF) window and BGO active shield to reduce the secondary neutron and gamma background. The simulations show that a 2 ns TOF window could reduce 99% of the secondary neutron flux hitting the detector. The results show that using both timing and active shielding can remove up to 85% of the background radiation which includes a 33% reduction by BGO subtraction.
引用
收藏
页码:7617 / 7635
页数:19
相关论文
共 50 条
  • [1] Assessment of Geant4 Prompt-Gamma Emission Yields in the Context of Proton Therapy Monitoring
    Pinto, Marco
    Dauvergne, Denis
    Freud, Nicolas
    Krimmer, Jochen
    Letang, Jean M.
    Testa, Etienne
    FRONTIERS IN ONCOLOGY, 2016, 6
  • [2] Geant4 Electron-Proton Integral Inelastic Cross Section Models
    Grichine, V. M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2023, 70 (06) : 1186 - 1188
  • [3] Simulation of prompt gamma-ray emission during proton radiotherapy
    Verburg, Joost M.
    Shih, Helen A.
    Seco, Joao
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (17) : 5459 - 5472
  • [4] Range verification of proton radiotherapy with prompt gamma rays
    Lau, Andy
    Chen, Yong
    Ahmad, Salahuddin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (04) : 507 - 514
  • [5] Evaluation of electromagnetic and nuclear scattering models in GATE/Geant4 for proton therapy
    Resch, Andreas F.
    Elia, Alessio
    Fuchs, Hermann
    Carlino, Antonio
    Palmans, Hugo
    Stock, Markus
    Georg, Dietmar
    Grevillot, Loic
    MEDICAL PHYSICS, 2019, 46 (05) : 2444 - 2456
  • [6] Analysis of Geant4 simulations of proton depth dose profiles for radiotherapy applications
    Lechner, Anton
    Pia, Maria Grazia
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 147 - +
  • [7] Prompt-gamma emission in GEANT4 revisited and confronted with experiment
    Wronska, Aleksandra
    Kasper, Jonas
    Ahmed, Arshiya Anees
    Andres, Achim
    Bednarczyk, Piotr
    Gazdowicz, Grzegorz
    Herweg, Katrin
    Hetzel, Ronja
    Konefal, Adam
    Kulessa, Pawel
    Magiera, Andrzej
    Rusiecka, Katarzyna
    Stachura, Damian
    Stahl, Achim
    Zieblinski, Miroslaw
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 88 : 250 - 261
  • [8] Assessment and improvements of Geant4 hadronic models in the context of prompt-gamma hadrontherapy monitoring
    Dedes, G.
    Pinto, M.
    Dauvergne, D.
    Freud, N.
    Krimmer, J.
    Letang, J. M.
    Ray, C.
    Testa, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (07) : 1747 - 1772
  • [9] Experimental validation of proton physics models of Geant4 for calculating stopping power ratio
    Liu, Ruirui
    Zhao, Xiandong
    Medrano, Maria
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)
  • [10] Benchmarking Geant4 hadronic models for prompt-γ monitoring in carbon ion therapy
    Vanstalle, Marie
    Mattei, Ilaria
    Sarti, Alessio
    Bellini, Fabio
    Bini, Fabiano
    Collamati, Francesco
    De Lucia, Erika
    Durante, Marco
    Faccini, Riccardo
    Ferroni, Fernando
    Finck, Christian
    Fiore, Salvatore
    Marafini, Michela
    Patera, Vincenzo
    Piersanti, Luca
    Rovituso, Marta
    Schuy, Christoph
    Sciubba, Adalberto
    Traini, Giacomo
    Voena, Cecilia
    La Tessa, Chiara
    MEDICAL PHYSICS, 2017, 44 (08) : 4276 - 4286