A magnetic diverter for charged particle background rejection in the SIMBOL-X telescope

被引:11
作者
Spiga, D. [1 ]
Fioretti, V. [2 ]
Bulgarelli, A. [2 ]
Dell'Orto, E. [1 ,4 ]
Foschini, L. [2 ]
Malaguti, G. [2 ]
Pareschi, G. [1 ]
Tagliaferri, G. [1 ]
Tiengo, A. [3 ]
机构
[1] INAF Osservatorio Astron Brera, Via E Bianchi 46, I-23807 Merate, LC, Italy
[2] INAF Ist Astrofis Spaziale & Fis Cosm, I-40129 Bologna, Italy
[3] INAF Ist Astrofis Spaziale & Fis Cosm, I-20133 Milan, Italy
[4] Univ Insubria, I-21100 Varese, Italy
来源
SPACE TELESCOPES AND INSTRUMENTATION 2008: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2 | 2008年 / 7011卷
关键词
X-ray telescopes; magnetic diverter; soft proton background; SIMBOL-X;
D O I
10.1117/12.789917
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Minimization of charged particle background in X-ray telescopes is a well known issue. Charged particles (chiefly protons and electrons) naturally present in the cosmic environment constitute an important background source when they collide with the X-ray detector. Even worse, a serious degradation of spectroscopic performances of the X-ray detector was observed in Chandra and Newton-XMM, caused by soft protons with kinetic energies ranging between 100 keV and some MeV being collected by the grazing-incidence mirrors and funneled to the detector. For a focusing telescope like SIMBOL-X, the exposure of the soft X-ray detector to the proton flux can increase significantly the instrumental background, with a consequent loss of sensitivity. In the worst case, it can also seriously compromise the detector duration. A well-known Countermeasure that can be adopted is the implementation of a properly-designed magnetic diverter, that should prevent high-energy particles from reaching the focal plane instruments of SIMBOL-X. Although Newton-XMM and Swift-XRT are equipped with magnetic diverters for electrons, the magnetic fields used are insufficient to effectively act on protons. In this paper, we simulate the behavior of a magnetic diverter for SIMBOL-X, consisting of commercially-available permanent magnets. The effects of SIMBOL-X optics is simulated through GEANT4 libraries. whereas the effect of the intense required magnetic fields is simulated along with specifically-written numerical codes in IDL.
引用
收藏
页数:11
相关论文
共 18 条
[1]  
ASCHENBACH B, 2007, SPIE P, V6688
[2]  
Blackwell WC, 2000, P SOC PHOTO-OPT INS, V4140, P111, DOI 10.1117/12.409105
[3]   The XMM-Newton EPIC background and the production of background blank sky event files [J].
Carter, J. A. ;
Read, A. M. .
ASTRONOMY & ASTROPHYSICS, 2007, 464 (03) :1155-1166
[4]   Grazing angle proton scattering: Effects on chandra and XMM-Newton X-ray telescopes [J].
Dichter, BK ;
Woolf, S .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (06) :2292-2295
[5]  
Firsov O.B, 1967, SOV PHYS DOKL, V11, P732
[6]   Ion transmission to the focal plane of the Chandra X-ray Observatory [J].
Kolodziejczak, JJ ;
Elsner, RF ;
Austin, RA ;
O'Dell, SL .
X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 :135-143
[7]   Update on the use of Geant4 for the simulation of low-energy protons scattering off X-ray mirrors at grazing incidence angles [J].
Lei, F ;
Nartallo, R ;
Nieminen, P ;
Daly, E ;
Evans, H ;
Truscott, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (06) :3408-3412
[8]   Modeling of proton-induced CCD degradation in the Chandra X-Ray Observatory [J].
Lo, DH ;
Srour, JR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (06) :2018-2023
[9]   Low-angle scattering of protons on the XMM-Newton optics and effects on the on-board CCD detectors [J].
Nartallo, R ;
Daly, E ;
Evans, H ;
Nieminen, P ;
Lei, F ;
Truscott, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) :1815-1821
[10]  
NARTALLO R, ESAESTECTOSEM00015RN