Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty: plates versus cannulated screws

被引:13
|
作者
Seeger, Joern Bengt [1 ,2 ]
Jaeger, S. [2 ]
Roehner, E. [3 ]
Dierkes, H. [4 ]
Wassilew, G. [3 ]
Clarius, M. [2 ,5 ]
机构
[1] Univ Hosp Giessen & Marburg UKGM, Dept Orthopaed & Orthopaed Surg, D-35392 Giessen, Germany
[2] Univ Heidelberg Hosp, Dept Orthopaed Traumatol & Paraplegiol, Lab Biomech & Implant Res, D-69118 Heidelberg, Germany
[3] Charite, Dept Traumatol & Orthopaed, D-10117 Berlin, Germany
[4] OCM, D-81369 Munich, Germany
[5] Vulpius Klin GmbH, Dept Orthopaed & Trauma Surg, D-74906 Bad Rappenau, Germany
关键词
Knee arthroplasty; Periprosthetic fracture; Osteosynthesis; Unicompartmental knee; Fracture load; Plates; Cannulated screws; INTERNAL-FIXATION;
D O I
10.1007/s00402-012-1649-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Periprosthetic tibial plateau fractures (TPF) are rare but represent a serious complication in unicompartmental knee arthroplasty. The most common treatment for these fractures is osteosynthesis with cannulated screws or plates. The aim of this study was to evaluate two different treatment options for periprosthetic fractures. The hypothesis was that angle-stable plates show significantly higher fracture loads than fixation with cannulated screws. Twelve matched, paired fresh-frozen tibiae with periprosthetic TPF were used for this study. In Group A, osteosyntheses with cannulated screws were performed, whereas in Group B plates fixated the periprosthetic fracture. DEXA bone density measurement and standard X-rays (AP and lateral) were performed before loading the tibiae under standardised conditions with a maximum load of up to 10.0 kN. After the specimens had been loaded, fracture patterns and fracture loads were analysed and correlated with BMD, BMI, bodyweight (BW), age and size of the tibial implant. In the plate group all tibiae fracture occured with a median load of F (max) = 2.64 (0.45-5.68) kN, whereas in the group with cannulated screws fractures occurred at a mean load of F (max) = 1.50 (0.27-3.51) kN. The difference was statistically significant at p < 0.05. Angle-stable plates showed significantly higher fracture loads than fixation with cannulated screws. Cannulated screws show a reduced stability of the tibial plateau. Therefore in periprosthetic TPF, osteosyntheses with angle-stable plates should be recommended instead of cannulated screws.
引用
收藏
页码:253 / 257
页数:5
相关论文
共 50 条
  • [21] Periprosthetic fractures about total knee arthroplasty
    Lombardo D.J.
    Siljander M.P.
    Sobh A.
    Moore D.D.
    Karadsheh M.S.
    MUSCULOSKELETAL SURGERY, 2020, 104 (2) : 135 - 143
  • [22] Periprosthetic fractures of the distal femur after total knee arthroplasty: Plate versus nail fixation
    Wallace, S. S.
    Bechtold, D.
    Sassoon, A.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (02) : 257 - 262
  • [23] Tibial Fixation Without Screws in Cementless Knee Arthroplasty
    Holloway, Ian P.
    Lusty, Patrick J.
    Walter, William L.
    Walter, William K.
    Zicat, Bernie A.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (01) : 46 - 51
  • [24] Periprosthetic tibial fractures in total knee arthroplasty - an outcome analysis of a challenging and underreported surgical issue
    Schreiner, Anna Janine
    Schmidutz, Florian
    Ateschrang, Atesch
    Ihle, Christoph
    Stoeckle, Ulrich
    Ochs, Bjoern Gunnar
    Gonser, Christoph
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19 : 323
  • [25] Management of Periprosthetic Fracture in Unicompartmental Knee Arthroplasty Patients: A Case Series
    Woo, Yew Lok
    Chin, Pak Lin
    Lo, Ngai Nung
    Chia, Shi-Lu
    Tay, Darren Keng Jin
    Yeo, Seng Jin
    PROCEEDINGS OF SINGAPORE HEALTHCARE, 2013, 22 (04) : 267 - 272
  • [26] Fixation of femoral neck fractures using divergent versus parallel cannulated screws
    Papanastassiou I.D.
    Mavrogenis A.F.
    Kokkalis Z.T.
    Nikolopoulos K.
    Skourtas K.
    Papagelopoulos P.J.
    Journal of Long-Term Effects of Medical Implants, 2011, 21 (01) : 63 - 69
  • [27] Cemented versus cementless unicompartmental knee arthroplasty
    Iniguez, C. Magaly
    Anastasiadis, Zoy
    Nazer, Maria Ignacia
    Sandoval, Rodrigo
    JOURNAL OF ISAKOS JOINT DISORDERS & ORTHOPAEDIC SPORTS MEDICINE, 2024, 9 (06)
  • [28] Periprosthetic fracture of the proximal tibia after lateral unicompartmental knee arthroplasty
    Kumar, Arun
    Chambers, Iain
    Wong, Paul
    JOURNAL OF ARTHROPLASTY, 2008, 23 (04) : 615 - 618
  • [29] The number of locking screws predicts the risk of nonunion and reintervention in periprosthetic total knee arthroplasty fractures treated with a nail
    Toro-Ibarguen A.
    Moreno-Beamud J.-A.
    Porras-Moreno M.-Á.
    Aroca-Peinado M.
    León-Baltasar J.-L.
    Jorge-Mora A.-A.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (4) : 661 - 664
  • [30] Dynamic hip screws versus cannulated screws for femoral neck fractures: a systematic review and meta-analysis
    Li, Lang
    Zhao, Xue
    Yang, Xiaodong
    Tang, Xueyang
    Liu, Ming
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)