A handheld flexible manipulator system for frontal sinus surgery

被引:14
作者
Coemert, Suat [1 ]
Roth, Robert [1 ]
Strauss, Gero [2 ]
Schmitz, Pia M. [2 ]
Lueth, Tim C. [1 ]
机构
[1] Tech Univ Munich, Inst Micro Technol & Med Device Technol, Boltzmannstr 15, D-85748 Garching, Germany
[2] IRDC GmbH, Int Reference & Dev Ctr Surg Technol, Kathe Kollwitz Str 64, D-04109 Leipzig, Germany
关键词
Flexible manipulator; Frontal sinus surgery; Handheld; Endoscopic surgery;
D O I
10.1007/s11548-020-02220-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Draf drainage is the standard treatment procedure for frontal sinus diseases. In this procedure, rigid angled endoscopes and rigid curved instruments are used. However, laterally located pathologies in the frontal sinus cannot be reached with rigid instrumentation. In order to assist surgeons with such complicated cases, we propose a novel handheld flexible manipulator system. Methods A cross section of 3 mm x 4.6 mm enables transnasal guiding of a flexible endoscope with 1.4 mm diameter and a standard flexible surgical instrument with up to 1.8 mm diameter into the frontal sinus with increased reachability. The developed system consists of an electrical discharge-machined flexure hinge-based nitinol manipulator arm and a purely mechanical handheld control unit. The corresponding control unit enables upward and left-right bending of the manipulator arm, translation, rolling, actuation and also quick exchange of the surgical instrument. In order to verify the fulfillment of performance requirements, tests regarding reachability and payload capacity were conducted. Results Reachability tests showed that the manipulator arm can be inserted into the frontal sinus and reach its lateral regions following a Draf IIa procedure. The system can exert forces of at least 2 N in the vertical direction and 1 N in the lateral direction which is sufficient for manipulation of frontal sinus pathologies. Conclusion Considering the fact that the anatomical requirements of the frontal sinus are not addressed satisfactorily in the development of prospective flexible instruments, the proposed system shows great potential in terms of therapeutic use owing to its small cross section and dexterity.
引用
收藏
页码:1549 / 1559
页数:11
相关论文
共 24 条
[1]  
Ashby MichaelF., 2014, MAT DESIGN ART SCI M
[2]  
Awtar S, 2010, PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, VOL 7, PTS A AND B, P829
[3]  
Barenklau M, 2016, THESIS
[4]   Forces Applied at the Skull Base during Transnasal Endoscopic Transsphenoidal Pituitary Tumor Excision [J].
Bekeny, James R. ;
Swaney, Philip J. ;
Webster, Robert J., III ;
Russell, Paul T. ;
Weaver, Kyle D. .
JOURNAL OF NEUROLOGICAL SURGERY PART B-SKULL BASE, 2013, 74 (06) :337-341
[5]  
Coemert S, 2018, DESIGN RELIABILITY S, V13, DOI [10.1115/IMECE2018-86551, DOI 10.1115/IMECE2018-86551]
[6]   Development and validation of an automated FEM-based design optimization tool for continuum compliant structures [J].
Coemert, Suat ;
Yalvac, Baturay ;
Bott, Vincent ;
Sun, Yilun ;
Lueth, Tim C. .
INTERNATIONAL JOURNAL OF MECHANICS AND MATERIALS IN DESIGN, 2021, 17 (02) :245-269
[7]   Suitability evaluation of various manufacturing technologies for the development of surgical snake-like manipulators from metals based on flexure hinges [J].
Coemert, Suat ;
Traeger, Mattias F. ;
Graf, Eva C. ;
Lueth, Tim C. .
3RD CIRP CONFERENCE ON BIOMANUFACTURING, 2017, 65 :1-6
[8]  
Conger BT, 2014, OTOLARYNG HEAD NECK, V151, P159, DOI 10.1177/0194599814529078
[9]  
Draf W, 2005, FRONTAL SINUS, P219, DOI 10.1007/3-540-27607-6_24
[10]  
GERBONI G, 2015, BIOINSPIR BIOMIM, V10, DOI DOI 10.1088/1748-3190/10/6/066013