Aortic Replacement After TEVAR-Diameter Correction With Modified Use of the Siena Prosthesis

被引:7
作者
Jassar, Arminder
Kreibich, Maximilian
Morlock, Julia
Kondov, Stoyan
Scheumann, Johannes
Kari, Fabian A.
Rylski, Bartosz
Siepe, Matthias
Jonaszik, Alexander
Keyl, Cornelius
Humburger, Frank
Beyersdorf, Friedhelm
Czerny, Martin
机构
[1] Univ Heart Ctr Freiburg Bad Krozingen, Dept Cardiovasc Surg, Freiburg, Germany
[2] Harvard Med Sch, Massachusetts Gen Hosp, Dept Cardiac Surg, Boston, MA USA
[3] Univ Hosp Freiburg, Dept Radiol, Freiburg, Germany
[4] Univ Heart Ctr Freiburg Bad Krozingen, Dept Anesthesiol, Freiburg, Germany
[5] Univ Hosp Freiburg, Dept Anesthesiol, Freiburg, Germany
[6] Albert Ludwigs Univ Freiburg, Fac Med, Freiburg, Germany
关键词
ANEURYSM REPAIR; DISSECTION;
D O I
10.1016/j.athoracsur.2017.08.029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. To report a new technique for diameter correction in patients after thoracic endovascular aortic repair (TEVAR) with large stent-grafts using the Vascutek Siena 4-branch collared prosthesis (Vascutek Terumo, Inchinnan, Scotland, UK) in patients undergoing thoracoabdominal (TA) aortic replacement. Methods. Within a 24-month period, 39 patients underwent TA replacement at our center. Of these, 6 patients had undergone previous TEVAR with large stent-grafts (42 to 48 mm diameter). Indications for TEVAR were aneurysm formation in 3 patients and residual type B aortic dissection (status post repair of type A dissection) in 3 patients. In these patients, the Vascutek Siena 4-branch prosthesis was used in a reversed fashion, removing the elephant trunk portion and using the sewing collar for diameter correction at the anastomotic site. Results. No 30-day mortality and no stroke or symptomatic spinal cord ischemia was observed. Median diameter of the TEVAR graft at the anastomotic site was 44 mm. Median size of the Siena graft used was 26 mm. Diameter correction was successfully achieved in all patients by tailoring the sewing collar of the Siena 4-branch prosthesis to the individual need according to the diameter of the distal end of the stent-graft. Conclusions. Using the sewing collar of the Vascutek Siena 4-branch prosthesis for diameter correction in patients undergoing TA replacement after previous TEVAR with large stent-grafts adds a useful adjunct to the armamentarium of options in a growing patient population. (C) 2018 by The Society of Thoracic Surgeons
引用
收藏
页码:587 / 591
页数:5
相关论文
共 12 条
[1]   Technical details making aortic arch replacement a safe procedure using the Thoraflex™ Hybrid prosthesis [J].
Czerny, Martin ;
Rylski, Bartosz ;
Kari, Fabian A. ;
Kreibich, Maximilian ;
Morlock, Julia ;
Scheumann, Johannes ;
Kondov, Stoyan ;
Suedkamp, Michael ;
Siepe, Matthias ;
Beyersdorf, Friedhelm .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 51 :15-19
[2]   Long-term results of thoracic endovascular aortic repair in atherosclerotic aneurysms involving the descending aorta [J].
Czerny, Martin ;
Funovics, Martin ;
Sodeck, Gottfried ;
Dumfarth, Julia ;
Schoder, Maria ;
Juraszek, Andrzej ;
Dziodzio, Tomasz ;
Zimpfer, Daniel ;
Loewe, Christian ;
Lammer, Johannes ;
Rosenhek, Raphael ;
Ehrlich, Marek ;
Grimm, Michael .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (06) :S179-S184
[3]   Mechanisms of Failure and Outcome of Secondary Surgical Interventions After Thoracic Endovascular Aortic Repair (TEVAR) [J].
Dumfarth, Julia ;
Michel, Marc ;
Schmidli, Juerg ;
Sodeck, Gottfried ;
Ehrlich, Marek ;
Grimm, Michael ;
Carrel, Thierry ;
Czerny, Martin .
ANNALS OF THORACIC SURGERY, 2011, 91 (04) :1141-1146
[4]   Retrograde Ascending Aortic Dissection During or After Thoracic Aortic Stent Graft Placement Insight From the European Registry on Endovascular Aortic Repair Complications [J].
Eggebrecht, Holger ;
Thompson, Matt ;
Rousseau, Herve ;
Czerny, Martin ;
Loenn, Lars ;
Mehta, Rajendra H. ;
Erbel, Raimund .
CIRCULATION, 2009, 120 (11) :S276-S281
[5]   Long-Term Outcome of Aortic Dissection With Patent False Lumen Predictive Role of Entry Tear Size and Location [J].
Evangelista, Artur ;
Salas, Armando ;
Ribera, Aida ;
Ferreira-Gonzalez, Ignacio ;
Cuellar, Hug ;
Pineda, Victor ;
Gonzalez-Alujas, Teresa ;
Bijnens, Bart ;
Permanyer-Miralda, Gaieta ;
Garcia-Dorado, David .
CIRCULATION, 2012, 125 (25) :3133-+
[6]   Thoracoabdominal aortic aneurysm repair after frozen elephant trunk procedure [J].
Folkmann, Sandra ;
Weiss, Gabriel ;
Pisarik, Harald ;
Czerny, Martin ;
Grabenwoger, Martin .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (01) :115-119
[7]  
Gottardi R, 2014, ANN THORAC SURG, V97, P739
[8]   A New Mechanism by Which an Acute Type B Aortic Dissection Is Primarily Complicated, Becomes Complicated, or Remains Uncomplicated [J].
Loewe, Christian ;
Czerny, Martin ;
Sodeck, Gottfried H. ;
Ta, Julie ;
Schoder, Maria ;
Funovics, Martin ;
Dumfarth, Julia ;
Ehrlich, Marek ;
Grimm, Michael ;
Lammer, Johannes .
ANNALS OF THORACIC SURGERY, 2012, 93 (04) :1215-1222
[9]   Open thoracoabdominal aortic aneurysm repair in the modern era: results from a 20-year single-centre experience [J].
Murana, Giacomo ;
Castrovinci, Sebastiano ;
Kloppenburg, Geoffrey ;
Yousif, Afram ;
Kelder, Hans ;
Schepens, Marc ;
de Maat, Gijs ;
Sonker, Uday ;
Morshuis, Wim ;
Heijmen, Robin .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (05) :1374-1381
[10]   Outcomes of Fenestrated/Branched Endografting in Post-dissection Thoracoabdominal Aortic Aneurysms [J].
Oikonomou, K. ;
Kopp, R. ;
Katsargyris, A. ;
Pfister, K. ;
Verhoeven, E. L. ;
Kasprzak, P. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 48 (06) :641-648