Cryogenic Self-Calibrating Noise Parameter Measurement System

被引:6
|
作者
Russell, Damon [1 ]
Weinreb, Sander [1 ]
机构
[1] CALTECH, Dept Elect Engn, Pasadena, CA 91125 USA
基金
美国国家航空航天局;
关键词
Low-noise amplifiers (LNAs); noise; noise measurement;
D O I
10.1109/TMTT.2012.2188813
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A system for measuring the noise parameters of a device at cryogenic temperatures is described. The method includes the thermal calibration of a module consisting of a noise diode, a dispersive coupling network, a temperature sensor, heater, and a bias-tee. The magnitude and phase of the reflection coefficient presented by the module vary rapidly with frequency and the noise output of the module can be thermally calibrated by changing the temperature of the module with an internal heater. The resulting variable impedance-calibrated noise source can be used to measure noise parameters of transistors or amplifiers over a frequency range of 0.4 to 12 GHz via the wideband frequency-variation method. The calibration scheme is not unique to the module and may be applied in general to any noise source. Calibration and noise parameter measurements are made at cryogenic temperatures on a discrete transistor and two different low-noise amplifiers. The results are compared against theoretical values and those obtained using independent measurements. To the best of the authors' knowledge, this is the first measurement of a transistor's noise parameters at cryogenic temperatures using such techniques.
引用
收藏
页码:1456 / 1467
页数:12
相关论文
共 50 条
  • [1] Self-Calibrating Stress Measurement System Based on Multidirectional Barkhausen Noise Measurements
    Piotrowski, Leszek
    Chmielewski, Marek
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2024, 43 (04)
  • [2] Experimental validation of a self-calibrating cryogenic mass flowmeter
    Janzen, A.
    Boersch, M.
    Burger, B.
    Drache, J.
    Ebersoldt, A.
    Erni, P.
    Feldbusch, F.
    Oertig, D.
    Grohmann, S.
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278
  • [3] SELF-CALIBRATING NOISE SOURCE USING SILICON
    ODELL, TH
    ELECTRONICS WORLD & WIRELESS WORLD, 1993, (1683): : 170 - 172
  • [4] Mesoscopic resistor as a self-calibrating quantum noise source
    Bergeal, N.
    Schackert, F.
    Frunzio, L.
    Prober, D. E.
    Devoret, M. H.
    APPLIED PHYSICS LETTERS, 2012, 100 (20)
  • [5] SELF-CALIBRATING SYSTEM MONITORS LIQUID LEVEL
    不详
    CHEMICAL ENGINEERING, 1973, 80 (25) : 78 - 78
  • [6] A SELF-CALIBRATING BIDIRECTIONAL INDOOR LOCALIZATION SYSTEM
    Kuxdorf-Alkirata, Nizam
    Werthwein, Thomas
    Heinemann, Anna
    Brueckmann, Dieter
    2017 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2017, : 3276 - 3280
  • [7] Self-calibrating interferometer
    不详
    OPTICS AND LASER TECHNOLOGY, 1998, 30 (02): : VIII - VIII
  • [8] Self-calibrating, real-time M-square measurement system
    Scaggs, Michael
    Haas, Gil
    LASER RESONATORS, MICRORESONATORS, AND BEAM CONTROL XIX, 2017, 10090
  • [9] Self-calibrating water quality monitoring system
    Armstrong, Trent
    Heath, Gail
    Smith, Casey
    Scott, Clark
    Jackson, Candice
    Proceedings of the Symposium on the Application of Geophyics to Engineering and Environmental Problems, SAGEEP, 2011, : 622 - 624
  • [10] Self-calibrating compass
    Noble, R
    ELECTRONICS WORLD, 1997, 103 (1736): : 630 - 633