摘要
A method for the simultaneous determination of hydrochlorothiazide (HCTZ) and losartan (LOS) in pharmaceutical formulations using differential-pulse voltammetry (DPV) was developed. Two very wellresolved and reproducible oxidation peaks of HCTZ and LOS, with separation of 0.23 V, were obtained in Britton-Robinson (BR) buffer (pH 9.5) using an anodically pretreated boron-doped diamond electrode. Under the optimum analytical experimental conditions, the voltammetric method exhibited linear responses for simultaneous determination of HCTZ and LOS in the concentration range 3.0 x 10(-6) to 7.4 x 10(-5) mol L-1 for both compounds, with detection limits of 1.2 x 10(-6) mol L-1 and 9.5 x 10(-7) MOI respectively. The proposed method was successfully applied in the simultaneous determination of LOS and HCTZ content in pharmaceutical formulations, whose accuracy was attested by good agreement of the results (paired t-test at a 95% confidence level) with those obtained using high performance liquid chromatography (HPLC). (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 38 条
[1]  
Ansari M., 2004, IJPT, V3, P21
[2]   Simultaneous determination of hydrochlorothiazide and losartan potassium in tablets by high-performance low-pressure chromatography using a multi-syringe burette coupled to a monolithic column [J].
Antonieta Obando, Maria ;
Estela, Jose Manuel ;
Cerda, Victor .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (06) :2349-2356
[3]   Square-wave voltammetric determination of bezafibrate in pharmaceutical formulations using a cathodically pretreated boron-doped diamond electrode [J].
Ardila, Jorge Armando ;
Sartori, Elen Romao ;
Rocha-Filho, Romeu C. ;
Fatibello-Filho, Orlando .
TALANTA, 2013, 103 :201-206
[4]   DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF SILDENAFIL CITRATE (VIAGRA®) IN PHARMACEUTICAL FORMULATIONS USING A BORON-DOPED DIAMOND ELECTRODE [J].
Batista, Erica Ferreira ;
Sartori, Elen Romao ;
Medeiros, Roberta Antigo ;
Rocha-Filho, Romeu C. ;
Fatibello-Filho, Orlando .
ANALYTICAL LETTERS, 2010, 43 (06) :1046-1054
[5]   Simultaneous determination of losartan and hydrochlorothiazide in tablets by high-performance liquid chromatography [J].
Carlucci, G ;
Palumbo, G ;
Mazzeo, P ;
Quaglia, MG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (01) :185-189
[6]   Electroanalysis at diamond-like and doped-diamond electrodes [J].
Compton, RG ;
Foord, JS ;
Marken, F .
ELECTROANALYSIS, 2003, 15 (17) :1349-1363
[7]   Application of multivariate calibration techniques to HPLC data for quantitative analysis of a binary mixture of hydrochlorathiazide and losartan in tablets [J].
Dinç, E ;
Üstündag, Ö .
CHROMATOGRAPHIA, 2005, 61 (5-6) :237-244
[8]   EVALUATION OF THE POTENTIALITIES OF A CARBON NANOTUBES/SILICONE RUBBER COMPOSITE ELECTRODE IN THE DETERMINATION OF HYDROCHLOROTHIAZIDE [J].
dos Santos, Sidney Xavier ;
Gomes Cavalheiro, Eder Tadeu .
ANALYTICAL LETTERS, 2012, 45 (11) :1454-1466
[9]   Analysis of binary mixtures of losartan potassium and hydrochlorothiazide by using high performance liquid chromatography, ratio derivative spectrophotometric and compensation technique [J].
Erk, N .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 24 (04) :603-611
[10]  
Gandini D, 1999, NEW DIAM FRONT C TEC, V9, P303