Implementation of Parallel Transmit Beamforming Using Orthogonal Frequency Division Multiplexing-Achievable Resolution and Interbeam Interference

被引:30
作者
Demi, Libertario [1 ]
Viti, Jacopo [2 ]
Kusters, Lieneke [1 ]
Guidi, Francesco [2 ]
Tortoli, Piero [2 ]
Mischi, Massimo [1 ]
机构
[1] Eindhoven Univ Technol, Lab Biomed Diagnost, NL-5600 MB Eindhoven, Netherlands
[2] Univ Florence, Lab Microelect Syst Design, Florence, Italy
关键词
VOLUMETRIC IMAGING-SYSTEM; PLANE-WAVE; ULTRASOUND;
D O I
10.1109/TUFFC.2013.6644735
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The speed of sound in the human body limits the achievable data acquisition rate of pulsed ultrasound scanners. To overcome this limitation, parallel beamforming techniques are used in ultrasound 2-D and 3-D imaging systems. Different parallel beamforming approaches have been proposed. They may be grouped into two major categories: parallel beamforming in reception and parallel beamforming in transmission. The first category is not optimal for harmonic imaging; the second category may be more easily applied to harmonic imaging. However, inter-beam interference represents an issue. To overcome these shortcomings and exploit the benefit of combining harmonic imaging and high data acquisition rate, a new approach has been recently presented which relies on orthogonal frequency division multiplexing (OFDM) to perform parallel beamforming in transmission. In this paper, parallel transmit beamforming using OFDM is implemented for the first time on an ultrasound scanner. An advanced open platform for ultrasound research is used to investigate the axial resolution and interbeam interference achievable with parallel transmit beamforming using OFDM. Both fundamental and second-harmonic imaging modalities have been considered. Results show that, for fundamental imaging, axial resolution in the order of 2 mm can be achieved in combination with interbeam interference in the order of -30 dB. For second-harmonic imaging, axial resolution in the order of 1 mm can be achieved in combination with interbeam interference in the order of -35 dB.
引用
收藏
页码:2310 / 2320
页数:11
相关论文
共 26 条
[21]   Comparison of Conventional Parallel Beamforming With Plane Wave and Diverging Wave Imaging for Cardiac Applications: A Simulation Study [J].
Tong, Ling ;
Gao, Hang ;
Choi, Hon Fai ;
D'hooge, Jan .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (08) :1654-1663
[22]   ULA-OP: An Advanced Open Platform for Ultrasound Research [J].
Tortoli, Piero ;
Bassi, Luca ;
Boni, Enrico ;
Dallai, Alessandro ;
Guidi, Francesco ;
Ricci, Stefano .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (10) :2207-2216
[23]   Clinical use of ultrasound tissue harmonic imaging [J].
Tranquart, F ;
Grenier, N ;
Eder, V ;
Pourcelot, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (06) :889-894
[24]   Comparison of fundamental, second harmonic, and superharmonic imaging: A simulation study [J].
van Neer, Paul L. M. J. ;
Danilouchkine, Mikhail G. ;
Verweij, Martin D. ;
Demi, Libertario ;
Voormolen, Marco M. ;
van der Steen, Anton F. W. ;
de Jong, Nico .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 130 (05) :3148-3157
[25]   HIGH-SPEED ULTRASOUND VOLUMETRIC IMAGING-SYSTEM .2. PARALLEL PROCESSING AND IMAGE DISPLAY [J].
VONRAMM, OT ;
SMITH, SW ;
PAVY, HG .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (02) :109-115
[26]   Nonlinear propagation applied to the improvement of resolution in diagnostic medical ultrasound [J].
Ward, B ;
Baker, AC ;
Humphrey, VF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (01) :143-154