Ultrasonic Evaluation of Bone Quality in Cadaver Ilia

被引:5
作者
Ghorayeb, Sleiman R. [1 ,2 ]
Rooney, David M. [1 ]
机构
[1] Hofstra Univ, Sch Engn & Appl Sci, Ultrasound Res Lab, Hempstead, NY 11549 USA
[2] North Shore Hosp, FIMR, Orthopaed Res Lab, Manhasset, NY USA
关键词
Noninvasive ultrasound; Bone loss; Bone quality; Bone mineral density; Osteoporosis; TRABECULAR BONE; HUMAN CALCANEUS; CANCELLOUS BONE; PROPAGATION; BACKSCATTER; ATTENUATION; VELOCITY; WAVES;
D O I
10.1007/s10439-012-0737-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Several imaging modalities have traditionally been utilized to assess bone health. However, none of these standards is capable of providing a clear rendition or display of the damaged bone layers caused, for instance, by osteoporosis. This study examines the use of ultrasound for non-invasive monitoring of bone quality in bone samples with various degrees of porosity. A user-defined region of interest (ROI) in the iliac portion of extracted human cadaver coxal bones is monitored and quantified. Raster C-scan images of the ROI were acquired and compared to basic physical measurements, and to bone scans using dual energy X-ray absorptiometry (DXA). A quantitative measure of the superficial sub-surface composite matrix (ScM) content was analyzed using linear regression with all physical and DXA measures. The trend in the degree of percent bone loss (PBL) measured by ultrasound (US) was found to be closely paralleled with that measured by DXA (R (2) = 0.82, p < .0005). Also, the trend in which PBL (US) correlated with bone mineral density (BMD) (R (2) = 0.62, p < .01) was found to exhibit a similar behavior when the latter was compared to dry mass density (DmD) of the bone samples (R (2) = 0.63, p < .01). However, when PBL (DXA) was compared to DmD, it did reveal a better linearity (R (2) = 0.69, p < .005) than the one obtained when PBL (US) was compared with the same DmD (R (2) = 0.45, p < .05). A similar outcome was observed when PBL (US) was compared with percent porosity (R (2) = 0.51, p < .05), as opposed to the better linearity exhibited between PBL (DXA) and porosity (R (2) = 0.86, p < .0005). Despite these slight variations, further analyses on the statistical significance between these correlations suggest that ultrasound can be an effective imaging technique in assessing the degree of bone damage, and can be used to assess the structural integrity of bones.
引用
收藏
页码:939 / 951
页数:13
相关论文
共 35 条
[1]  
[Anonymous], OST THIN BON
[2]  
Bankman I., 2000, Handbook of medical imaging: processing and analysis
[3]  
Bartel DonaldL., 2006, Orthopaedic Biomechanics: Mechanics and Design in Musculoskeletal Systems, V1
[4]  
Binkowski M., 2003, ARTIF INTEL METHODS, P145
[5]   Cortical bone in the human femoral neck: Three-dimensional appearance and porosity using synchrotron radiation [J].
Bousson, V ;
Peyrin, F ;
Berot, C ;
Hausard, M ;
Sautet, A ;
Laredo, JD .
JOURNAL OF BONE AND MINERAL RESEARCH, 2004, 19 (05) :794-801
[6]  
BRIGHTON CT, 1979, ELECT PROPERTIES BON
[7]  
Cardoso L., 2009, POROMECHANICS
[8]   Quantitative assessment of osteoporosis from the tibia shaft by ultrasound techniques [J].
Chen, TS ;
Chen, PJ ;
Fung, CS ;
Lin, CJ ;
Yao, WJ .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (02) :141-145
[9]   Quantitative computed tomography-based finite element models of the human lumbar vertebral body: Effect of element size on stiffness, damage, and fracture strength predictions [J].
Crawford, RP ;
Rosenberg, WS ;
Keaveny, TM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (04) :434-438
[10]   Velocity dispersion of acoustic waves in cancellous bone [J].
Droin, P ;
Berger, G ;
Laugier, P .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (03) :581-592