Optimization of an Anti-poly(ethylene glycol) (anti-PEG) Cell-Based Capture System To Quantify PEG and PEGylated Molecules

被引:18
作者
Lin, Wen-Wei [1 ]
Hsieh, Yuan-Chin [2 ]
Cheng, Yi-An [2 ]
Chuang, Kuo-Hsiang [8 ]
Huang, Chien-Chiao [3 ,5 ,6 ]
Chuang, Chih-Hung [4 ]
Chen, I-Ju [2 ]
Cheng, Kai-Wen [1 ]
Lu, Yun-Chi [2 ]
Cheng, Ta-Chun [5 ]
Wang, Yeng-Tseng [7 ]
Roffler, Steve R. [3 ,9 ]
Cheng, Tian-Lu [1 ,2 ,5 ,6 ]
机构
[1] Natl Sun Yat Sen Univ, Inst Biomed Sci, Kaohsiung, Taiwan
[2] Kaohsiung Med Univ, Coll Med, Grad Inst Med, Kaohsiung, Taiwan
[3] Kaohsiung Med Univ, Grad Inst Clin Med, Kaohsiung, Taiwan
[4] Kaohsiung Med Univ, Dept Med Lab Sci & Biotechnol, Kaohsiung, Taiwan
[5] Kaohsiung Med Univ, Ctr Biomarkers & Biotech Drugs, Kaohsiung, Taiwan
[6] Kaohsiung Med Univ, Dept Biomed Sci & Environm Biol, Kaohsiung, Taiwan
[7] Kaohsiung Med Univ, Dept Biochem, Kaohsiung, Taiwan
[8] Taipei Med Univ, Grad Inst Pharmacognosy, Taipei, Taiwan
[9] Acad Sinica, Inst Biomed Sci, Taipei, Taiwan
关键词
CHRONIC HEPATITIS-C; POLYETHYLENE-GLYCOL; POLY(ETHYLENE GLYCOL); IN-VIVO; MASS-SPECTROMETRY; DRUG-DELIVERY; PEPTIDE; NANOPARTICLES; EFFICACY; PHARMACEUTICALS;
D O I
10.1021/acs.analchem.6b03614
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sensitive determination of the pharmacokinetics of PEGylated molecules can accelerate the process of drug development. Here, we combined different anti-PEG Fab expressing 293T cells as capture cells (293T/3.3, 293T/6.3, and 293T/15-2b cells) with four detective anti-PEG antibodies (3.3, 6.3, 7A4, or 15-2b) to optimize an anti-PEG cell-based sandwich ELISA. Then, we quantified free PEG (mPEG(5K)-NH2 and mPEG(5K)-NH2) or PEG-conjugated small molecules (mPEG(5K)-biotin and mPEG(5K)-NIR797), proteins (PegIntron and Pegasys), and nanoparticles (Liposomal-Doxorubicin and quantum-dots). The combination of 293T/15-2b cells and the 7A4 detection antibody was best sensitivity for free PEG, PEG-like molecules, and PEGylated proteins with detection at ng mL(-1) levels. On the other hand, 293T/3.3 cells combined with the 15-2b antibody had the highest sensitivity for quantifying Lipo-Dox at 2 ng mL(-1). All three types of anti-PEG cells combined with the 15-2b antibody had high sensitivity for quantum dot quantification down to 7 pM. These results suggest that the combination of 293T/15-2b cells and 7A4 detection antibody is the optimal pair for sensitive quantification of free PEG, PEG-like molecules, and PEGylated proteins, whereas the 293T/3.3 cells combined with 15-2b are more suitable for quantifying PEGylated nanoparticles. The optimized anti-PEG cell-based sandwich ELISA can provide a sensitive, precise, and convenient tool for the quantification of a range of PEGylated molecules.
引用
收藏
页码:12371 / 12379
页数:9
相关论文
共 55 条
[1]   BIOTIN-AVIDIN-AMPLIFIED ENZYME-IMMUNOASSAY FOR DETECTION OF HERPES-SIMPLEX VIRUS-ANTIGEN IN CLINICAL SPECIMENS [J].
ADLERSTORTHZ, K ;
KENDALL, C ;
KENNEDY, RC ;
HENKEL, RD ;
DREESMAN, GR .
JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 18 (06) :1329-1334
[2]   Noninvasive imaging of quantum dots in mice [J].
Ballou, B ;
Lagerholm, BC ;
Ernst, LA ;
Bruchez, MP ;
Waggoner, AS .
BIOCONJUGATE CHEMISTRY, 2004, 15 (01) :79-86
[3]   Doxil® - The first FDA-approved nano-drug: Lessons learned [J].
Barenholz, Yechezkel .
JOURNAL OF CONTROLLED RELEASE, 2012, 160 (02) :117-134
[4]   A stimulus-responsive contrast agent for ultrasound molecular imaging [J].
Borden, Mark A. ;
Zhang, Hua ;
Gillies, Robert J. ;
Dayton, Paul A. ;
Ferrara, Katherine W. .
BIOMATERIALS, 2008, 29 (05) :597-606
[5]  
Brinckerhoff LH, 1999, INT J CANCER, V83, P326, DOI 10.1002/(SICI)1097-0215(19991029)83:3<326::AID-IJC7>3.0.CO
[6]  
2-X
[7]   Biodistribution of dual radiolabeled lipidic nanocapsules in the rat using scintigraphy and γ counting [J].
Cahouet, A ;
Denizot, B ;
Hindré, F ;
Passirani, C ;
Heurtault, B ;
Moreau, M ;
Le Jeune, JJ ;
Benoît, JP .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2002, 242 (1-2) :367-371
[8]   Quantitative determination of pegylated consensus interferon in rhesus monkey serum using a competitive enzyme-linked immunosorbent assay [J].
Cao, Jin ;
Du, Yu ;
Tian, Hong ;
Gao, Xiang-dong ;
Yao, Wen-bing .
IMMUNOPHARMACOLOGY AND IMMUNOTOXICOLOGY, 2009, 31 (04) :543-549
[9]   IGG ANTIBODY-RESPONSE TO POLYETHYLENE GLYCOL-MODIFIED ADENOSINE-DEAMINASE IN PATIENTS WITH ADENOSINE-DEAMINASE DEFICIENCY [J].
CHAFFEE, S ;
MARY, A ;
STIEHM, ER ;
GIRAULT, D ;
FISCHER, A ;
HERSHFIELD, MS .
JOURNAL OF CLINICAL INVESTIGATION, 1992, 89 (05) :1643-1651
[10]   Therapeutic antibody fragments with prolonged in vivo half-lives [J].
Chapman, AP ;
Antoniw, P ;
Spitali, M ;
West, S ;
Stephens, S ;
King, DJ .
NATURE BIOTECHNOLOGY, 1999, 17 (08) :780-783