Hip abductor moment arm - a mathematical analysis for proximal femoral replacement

被引:26
作者
Henderson, Eric R. [1 ]
Marulanda, German A. [1 ]
Cheong, David [2 ]
Temple, H. Thomas [3 ]
Letson, G. Douglas [2 ]
机构
[1] Univ S Florida, Dept Orthopaed & Sports Med, Tampa, FL 33612 USA
[2] Univ S Florida, Coll Med, H Lee Moffitt Canc Ctr & Res Inst, Sarcoma Div, Tampa, FL 33612 USA
[3] Univ Miami, Orthopaed Oncol Div, Dept Orthopaed Surg, Miami, FL USA
关键词
MODULAR FEMUR; FOLLOW-UP; RECONSTRUCTION; ARTHROPLASTY; PROSTHESIS; CARTILAGE; SALVAGE; TUMOR; FALLS;
D O I
10.1186/1749-799X-6-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Patients undergoing proximal femoral replacement for tumor resection often have compromised hip abductor muscles resulting in a Trendelenberg limp and hip instability. Commercially available proximal femoral prostheses offer several designs with varying sites of attachment for the abductor muscles, however, no analyses of these configurations have been performed to determine which design provides the longest moment arm for the hip abductor muscles during normal function. Methods: This study analyzed hip abductor moment arm through hip adduction and abduction with a trigonometric mathematical model to evaluate the effects of alterations in anatomy and proximal femoral prosthesis design. Prosthesis dimensions were taken from technical schematics that were obtained from the prosthesis manufacturers. Manufacturers who contributed schematics for this investigation were Stryker Orthopaedics and Biomet. Results: Superior and lateral displacement of the greater trochanter increased the hip abductor mechanical advantage for single-leg stance and adduction and preserved moment arm in the setting of Trendelenberg gait. Hip joint medialization resulted in less variance of the abductor moment arm through coronal motion. The Stryker GMRS endoprosthesis provided the longest moment arm in single-leg stance. Conclusions: Hip abductor moment arm varies substantially throughout the hip's range of motion in the coronal plane. Selection of a proximal femur endoprosthesis with an abductor muscle insertion that is located superiorly and laterally will optimize hip abductor moment arm in single-leg stance compared to one located inferiorly or medially.
引用
收藏
页数:10
相关论文
共 24 条
[1]  
Antolic V, 1994, ACTA ORTHOPAEDICA BE, V60, P371
[2]   BIOMECHANICAL INVESTIGATION OF HUMAN HIP [J].
CROWNINSHIELD, RD ;
JOHNSTON, RC ;
ANDREWS, JG ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1978, 11 (1-2) :75-85
[3]   Modular prosthetic replacement of the proximal femur after resection of a bone tumour - A long-term follow-up [J].
Donati, D ;
Zavatta, M ;
Gozzi, E ;
Giacomini, S ;
Campanacci, L ;
Mercuri, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (08) :1156-1160
[4]   A 3-DIMENSIONAL BIOMECHANICAL MODEL OF HIP MUSCULATURE [J].
DOSTAL, WF ;
ANDREWS, JG .
JOURNAL OF BIOMECHANICS, 1981, 14 (11) :803-+
[5]  
GEHLSEN GM, 1990, ARCH PHYS MED REHAB, V71, P739
[6]   DETERIORATION OF ARTICULAR-CARTILAGE CAUSED BY CONTINUOUS COMPRESSION IN A MOVING RABBIT JOINT - LIGHT AND ELECTRON-MICROSCOPIC STUDY [J].
GRITZKA, TL ;
FRY, LR ;
CHEESMAN, RL ;
LAVIGNE, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1698-1720
[7]   LOWER-EXTREMITY FUNCTION IN PERSONS OVER THE AGE OF 70 YEARS AS A PREDICTOR OF SUBSEQUENT DISABILITY [J].
GURALNIK, JM ;
FERRUCCI, L ;
SIMONSICK, EM ;
SALIVE, ME ;
WALLACE, RB .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (09) :556-561
[8]   Proximal femoral replacement prosthesis for salvage of failed hip arthroplasty - Complications in a 2-11 year follow-up study in 19 elderly patients [J].
Haentjens, P ;
DeBoeck, H ;
Opdecam, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (01) :37-42
[9]   BIOMECHANICAL STUDY OF VARIOUS GREATER TROCHANTER POSITIONS [J].
IGLIC, A ;
ANTOLIC, V ;
SRAKAR, F ;
KRALJIGLIC, V ;
MACEKLEBAR, A ;
BRAJNIK, D .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1995, 114 (02) :76-78
[10]  
INMAN VT, 1947, J BONE JOINT SURG, V29, P607