Visual and multiplex detection of nucleic acid sequence by multiple cross displacement amplification coupled with gold nanoparticle-based lateral flow biosensor

被引:28
|
作者
Wang, Yi [1 ]
Wang, Yan [1 ]
Zhang, Lu [1 ]
Xu, Jianguo [1 ]
Ye, Changyun [1 ]
机构
[1] Chinese Ctr Dis Control & Prevent, Collaborat Innovat Ctr Diag & Treatment Infect Di, State Key Lab Infect Dis Prevent & Control, Natl Inst Communicable Dis Control & Prevent, Beijing 102206, Peoples R China
关键词
MCDA; LFB; MCDA-LFB; LoD; Salmonella spp; Shigella spp; ISOTHERMAL-AMPLIFICATION; SALMONELLA; DIAGNOSIS; FAMILY; PCR;
D O I
10.1016/j.snb.2016.10.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Here, we reported on the establishment of a nearly instrument free, simple and rapid molecular technique, which incorporated multiple cross displacement amplification coupled with lateral flow biosensor (MCDA-LFB) for the visual, sensitive and specific detection of nucleic acid sequence. The MCDA-LFB assay was able to simultaneously detect and correctly differentiate multiple targets using a 40 min amplification reaction followed by a 2 min incubation of the products on the visualization biosensor. The biosensor was devised to detect three targets, a chromatography control, the MCDA target amplicon I and II, and the interpretation of test results is based on the appearance of red lines on the reaction pad. As a proof of concept, Shigella and Salmonella strains were detected by MCDA-LFB technique to demonstrate the availability of target analysis. The analytical sensitivity, specificity and practical application of MCDA-LFB assay were successfully evaluated in pure culture and blood samples, and the whole procedure, including specimen (blood sample) processing (35 min), isothermal reaction (40 min), and result reporting (5 min), was completed within 80 min. Therefore, the simplicity, rapidity and nearly apparatus-free platform of the MCDA-LFB assay make it practical for point-of-care testing, field detection, 'on-site' diagnosis and more. (C) 2016 Published by Elsevier B.V.
引用
收藏
页码:1283 / 1293
页数:11
相关论文
共 50 条
  • [21] Development of multiple cross displacement amplification label-based gold nanoparticles lateral flow biosensor for detection of Listeria monocytogenes
    Wang, Yi
    Li, Hui
    Wang, Yan
    Li, Hui
    Luo, Lijuan
    Xu, Jianguo
    Ye, Changyun
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 : 473 - 486
  • [22] Visual and rapid identification of Chlamydia trachomatis and Neisseria gonorrhoeae using multiplex loop-mediated isothermal amplification and a gold nanoparticle-based lateral flow biosensor
    Chen, Xu
    Zhou, Qingxue
    Yuan, Wei
    Shi, Yuanfang
    Dong, Shilei
    Luo, Xinhua
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2023, 13
  • [23] Detection of Haemophilus influenzae by loop-mediated isothermal amplification coupled with nanoparticle-based lateral flow biosensor assay
    Qilong Cao
    Shaoshuai Liang
    Feng Lin
    Jun Cao
    Lin Wang
    Hui Li
    Mengyang Liu
    Yajuan Wang
    Lijun Zhao
    Xiaolong Cao
    Yan Guo
    BMC Microbiology, 22
  • [24] Detection of Haemophilus influenzae by loop-mediated isothermal amplification coupled with nanoparticle-based lateral flow biosensor assay
    Cao, Qilong
    Liang, Shaoshuai
    Lin, Feng
    Cao, Jun
    Wang, Lin
    Li, Hui
    Liu, Mengyang
    Wang, Yajuan
    Zhao, Lijun
    Cao, Xiaolong
    Guo, Yan
    BMC MICROBIOLOGY, 2022, 22 (01)
  • [25] Rapid and Visual Detection of SARS-CoV-2 Using Multiplex Reverse Transcription Loop-Mediated Isothermal Amplification Linked With Gold Nanoparticle-Based Lateral Flow Biosensor
    Chen, Xu
    Zhou, Qingxue
    Li, Shijun
    Yan, Hao
    Chang, Bingcheng
    Wang, Yuexia
    Dong, Shilei
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2021, 11
  • [26] Multiple Cross Displacement Amplification Coupled With Gold Nanoparticles-Based Lateral Flow Biosensor for Detection of the Mobilized Colistin Resistance Gene mcr-1
    Gong, Lin
    Liu, Ernan
    Che, Jie
    Li, Juan
    Liu, Xiaoli
    Xu, Huiqiong
    Liang, Jiansheng
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2019, 9
  • [27] Development of Multiple Cross Displacement Amplification Label-Based Gold Nanoparticles Lateral Flow Biosensor for Detection of Shigella spp.
    Wang, Yi
    Wang, Yan
    Xu, Jianguo
    Ye, Changyun
    FRONTIERS IN MICROBIOLOGY, 2016, 7
  • [28] Multiple Cross Displacement Amplification Coupled with Lateral Flow Biosensor (MCDA-LFB) for rapid detection of Legionella pneumophila
    Luxi Jiang
    Rumeng Gu
    Xiaomeng Li
    Meijun Song
    Xiaojun Huang
    Deguang Mu
    BMC Microbiology, 22
  • [29] Multiple Cross Displacement Amplification Coupled with Lateral Flow Biosensor (MCDA-LFB) for rapid detection of Legionella pneumophila
    Jiang, Luxi
    Gu, Rumeng
    Li, Xiaomeng
    Song, Meijun
    Huang, Xiaojun
    Mu, Deguang
    BMC MICROBIOLOGY, 2022, 22 (01)
  • [30] A gold nanoparticle-based lateral flow biosensor for sensitive visual detection of the potato late blight pathogen, Phytophthora infestans
    Zhan, Fangfang
    Wang, Tian
    Iradukunda, Linda
    Zhan, Jiasui
    ANALYTICA CHIMICA ACTA, 2018, 1036 : 153 - 161