Polymer systems designed specifically for DNA sequencing by microchip electrophoresis: A comparison with commercially available materials

被引:16
作者
Fredlake, Christopher P. [2 ]
Hert, Daniel G. [2 ]
Root, Brian E. [3 ]
Barron, Annelise E. [1 ,2 ]
机构
[1] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[2] Northwestern Univ, Dept Chem & Biol Engn, Evanston, IL USA
[3] Northwestern Univ, Dept Mat Sci & Engn, Evanston, IL 60208 USA
关键词
Band broadening; Capillary electrophoresis; DNA sequencing; Microchip electrophoresis; Polymer solution;
D O I
10.1002/elps.200800352
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrophoresis-based DNA sequencing is the only proven technology for the de novo sequencing of large and complex genomes. Miniaturization of capillary array electrophoresis (CAE) instruments can increase sequencing throughput and decrease cost while maintaining the high quality and long read lengths that has made CAE so successful for de novo sequencing. The limited availability of high-performance polymer matrices and wall coatings designed specifically for microchip-sequencing platforms continues to be a major barrier to the successful development of a commercial microchip-sequencing instrument. It has been generally assumed that the matrices and wall coatings that have been developed for use in commercial CAE instruments will be able to be implemented directly into microchip devices with little to no change in sequencing performance. Here, we show that sequencing matrices developed specifically for microchip electrophoresis systems can deliver read lengths that are 150-300 bases longer on chip than some of the most widely used polymer-sequencing matrices available commercially. Additionally, we show that the coating ability of commercial matrices is much less effective in the borosilicate chips used in this study. These results lead to the conclusion that new materials must be developed to make high-performance microfabricated DNA-sequencing instruments a reality.
引用
收藏
页码:4652 / 4662
页数:11
相关论文
共 49 条
  • [1] Albarghouthi M, 2001, ELECTROPHORESIS, V22, P737, DOI 10.1002/1522-2683(200102)22:4<737::AID-ELPS737>3.0.CO
  • [2] 2-S
  • [3] Microfabricated bioprocessor for integrated nanoliter-scale Sanger DNA sequencing
    Blazej, Robert G.
    Kumaresan, Palani
    Mathies, Richard A.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (19) : 7240 - 7245
  • [4] Human polymorphism and human-chimpanzee divergence in pseudoautosomal region correlate with local recombination rate
    Bussell, JJ
    Pearson, NM
    Kanda, R
    Filatov, DA
    Lahn, BT
    [J]. GENE, 2006, 368 : 94 - 100
  • [5] Advances in sequencing technology
    Chan, EY
    [J]. MUTATION RESEARCH-FUNDAMENTAL AND MOLECULAR MECHANISMS OF MUTAGENESIS, 2005, 573 (1-2) : 13 - 40
  • [6] Human genome: Patchwork people
    Check, E
    [J]. NATURE, 2005, 437 (7062) : 1084 - 1086
  • [7] Separations of DNA fragments by capillary electrophoresis in N-substituted polyacrylamides
    Chiari, M
    Riva, S
    Gelain, A
    Vitale, A
    Turati, E
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) : 347 - 355
  • [8] Poly(acrylamide-co-alkylacrylamides) for electrophoretic DNA purification in microchannels
    Chiesl, TN
    Shi, W
    Barron, AE
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (03) : 772 - 779
  • [9] SEPARATION AND ANALYSIS OF DNA-SEQUENCE REACTION-PRODUCTS BY CAPILLARY GEL-ELECTROPHORESIS
    COHEN, AS
    NAJARIAN, DR
    KARGER, BL
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01): : 49 - 60
  • [10] Sparsely cross-linked "nanogel" matrixes as fluid, mechanically stabilized polymer networks for high-throughput microchannel DNA sequencing
    Doherty, EAS
    Kan, CW
    Paegel, BM
    Yeung, SHI
    Cao, ST
    Mathies, RA
    Barron, AE