Results of Arthroscopic Repair of Partial- or Full-Thickness Longitudinal Medial Meniscal Tears by Single or Double Vertical Sutures Using the Inside-Out Technique

被引:30
作者
Haklar, Ugur [1 ]
Donmez, Ferdi [1 ]
Basaran, Serdar Hakan [1 ]
Canbora, Mehmet Kerem [1 ]
机构
[1] Acibadem Kadikoy Hosp, Dept Orthoped & Traumatol, TR-34718 Istanbul, Turkey
关键词
longitudinal medial meniscal tears; inside out; vertical suture; meniscal repair; CRUCIATE LIGAMENT RECONSTRUCTION; PARTIAL MENISCECTOMY;
D O I
10.1177/0363546512472046
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although numerous studies have assessed arthroscopic repair of meniscal tears, no study has described the repair of partial-or full-thickness longitudinal medial meniscal tears using single or double vertical sutures. Purpose: To present the intermediate-term results of medial meniscal tears repaired with single or double vertical sutures. Study Design: Case series; Level of evidence, 4. Methods: The authors evaluated the results of 112 longitudinal medial meniscal tears treated with inside-out single or double vertical sutures, with or without anterior cruciate ligament (ACL) reconstruction, based on the clinical resolution of symptoms, the Lysholm knee scoring scale, and the Tegner activity scale. Re-examination was also performed by magnetic resonance imaging after the repair. The length of the tears was evaluated arthroscopically. Eighty-five tears of 112 were >2 cm in length, and 27 were tears <= 2 cm. Eighty-nine (79.4%) of the 112 repairs were performed in conjunction with ACL reconstructions, and the remaining 23 (20.6%) repairs were performed in ACL-intact knees. The tear type of the menisci in our study was full thickness in 66 (58.9%) cases and partial thickness in 46 (41.1%) cases. Double vertical sutures were used for full-thickness tears, and single vertical sutures were used for partial-thickness tears. Results: The cases were evaluated after a mean follow-up duration of 49.3 months (range, 12-88 months). Clinical and radiological examination results determined that 99 (88.4%) meniscal repairs had healed, and the remaining 13 cases (10.6%) were considered to be failures. The healing rate of the full-thickness group was 80.3%, while in the partial-thickness group, the rate was 100%. The mean Lysholm score improved significantly from a preoperative value of 63.8 to a postoperative value of 89.5 (P < .001). The mean Tegner activity score was 3.3 preoperatively and 6.7 postoperatively (P < .001). Logistic regression analysis found that concurrent ACL reconstruction, tear length, and smoking as factors had a significant effect on meniscal healing. Conclusion: Single or double vertical sutures using the inside-out technique provide a high rate of healing in longitudinal medial meniscal tears.
引用
收藏
页码:596 / 602
页数:7
相关论文
共 40 条
[1]   Arthroscopic all-inside suture repair of medial meniscus lesion in anterior cruciate ligament-deficient knees: Results of second-look arthroscopies in 39 cases [J].
Ahn, JH ;
Wang, JH ;
Yoo, JC .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (09) :936-945
[2]   Arthroscopic meniscal allograft transplantation without bone plugs [J].
Alentorn-Geli, Eduard ;
Seijas Vazquez, Roberto ;
Garcia Balletbo, Montserrat ;
Alvarez Diaz, Pedro ;
Steinbacher, Gilbert ;
Cusco Segarra, Xavier ;
Rius Vilarrubia, Marta ;
Cugat Bertomeu, Ramon .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (02) :174-182
[3]   Clinical results of meniscus repair in patients 40 years and older [J].
Barrett, GR ;
Field, MH ;
Treacy, SH ;
Ruff, CG .
ARTHROSCOPY, 1998, 14 (08) :824-829
[4]  
Benazzo F, 2010, TECH KNEE SURG, V9, P159
[5]   Update on meniscal repair [J].
Bollier, Matthew .
CURRENT ORTHOPAEDIC PRACTICE, 2011, 22 (06) :509-513
[6]   Implantation of a synthetic meniscal scaffold improves joint contact mechanics in a partial meniscectomy cadaver model [J].
Brophy, Robert H. ;
Cottrell, Jocelyn ;
Rodeo, Scott A. ;
Wright, Timothy M. ;
Warren, Russell F. ;
Maher, Suzanne A. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2010, 92A (03) :1154-1161
[7]  
Cole Brian J, 2003, Instr Course Lect, V52, P383
[8]   Marrow stimulating technique to augment meniscus repair [J].
Freedman, KB ;
Nho, SJ ;
Cole, BJ .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (07) :794-798
[9]   Meniscal repair using the FasT-Fix all-inside meniscal repair device [J].
Haas, AL ;
Schepsis, AA ;
Hornstein, J ;
Edgar, CM .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (02) :167-175
[10]   Recombinant human platelet-derived growth factor: Biology and clinical applications [J].
Hollinger, Jeffrey O. ;
Hart, Charles E. ;
Hirsch, Steven N. ;
Lynch, Samuel ;
Friedlaender, Gary E. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A :48-54