A soft-polymer piezoelectric bimorph cantilever-actuated peristaltic micropump

被引:39
作者
Graf, Neil J. [1 ]
Bowser, Michael T. [1 ]
机构
[1] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
关键词
D O I
10.1039/b805252b
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A peristaltic micropump was fabricated and characterized. The micropump was fabricated using soft lithography, and actuated using piezoelectric bimorph cantilevers. The micropump channel was formed by bonding two layers of PDMS, mixed at 5 : 1 and 30: 1 ratios. The channel was fabricated in the 5 : 1 layer using replica molding (REM), where a very simple and inexpensive template was made by straddling a 75 mu m wire over a glass substrate, followed by covering and smoothing over the wire with a piece of aluminium foil. Not only was this template inexpensive and extremely simple to fabricate, it also created a rounded cross-sectional geometry which is favorable for complete valve shutoff. The cantilevers were driven at V-p = +/- 90 V with amplified square wave signals generated by a virtual function generator created in LabVIEW Connections to the micropump were made by placing capillary tubes in the channel, and then sealed between the two layers of PDMS. Machined aluminium clamps were adhered to the tips of the cantilevers with general purpose adhesive. These clamps allowed for aluminium valves, with finely machined tips of dimensions 3 mm by 200 mu m, to be held firmly in place. The variables characterized for this micropump were flow rate, maximum attainable backpressure, free cantilever deflection, valve shutoff, and valve leakage. Three actuation patterns with phase differences of 60, 90, and 120 degrees were compared for flow rate and maximum backpressure. It was determined that the 120 degrees signal outperformed the 60 degrees and 90 degrees signals for both maximum flowrate and maximum attainable backpressure. The maximum and minimum flowrates demonstrated by the micropump were 289 nL min(-1) and 53 nL min(-1), respectively. The maximum backpressure attained was 35 300 Pa. It was also demonstrated that the valves fully closed the channels upon actuation, with minimal observed leakage.
引用
收藏
页码:1664 / 1670
页数:7
相关论文
共 27 条
[1]   Thin-film shape-memory alloy actuated micropumps [J].
Benard, WL ;
Kahn, H ;
Heuer, AH ;
Huff, MA .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 1998, 7 (02) :245-251
[2]   Microfluidic chip for low-flow push-pull perfusion sampling in vivo with on-line analysis of amino acids [J].
Cellar, NA ;
Burns, ST ;
Meiners, JC ;
Chen, H ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 2005, 77 (21) :7067-7073
[3]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[4]   Monolithic membrane valves and diaphragm pumps for practical large-scale integration into glass microfluidic devices [J].
Grover, WH ;
Skelley, AM ;
Liu, CN ;
Lagally, ET ;
Mathies, RA .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 89 (03) :315-323
[5]   On-chip thermopneumatic pressure for discrete drop pumping [J].
Handique, K ;
Burke, DT ;
Mastrangelo, CH ;
Burns, MA .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1831-1838
[6]   Hybrid sample-inverted reflow and soft-lithography technique for fabrication of conicoid microlens arrays [J].
He, M ;
Yuan, XC ;
Bu, J ;
Cheong, WC .
APPLIED OPTICS, 2005, 44 (19) :4130-4135
[7]   A stand-alone peristaltic micropump based on piezoelectric actuation [J].
Jang, Ling-Sheng ;
Li, Yuan-Jie ;
Lin, Sung-Ju ;
Hsu, Yi-Chu ;
Yao, Wu-Sung ;
Tsai, Mi-Ching ;
Hou, Ching-Cheng .
BIOMEDICAL MICRODEVICES, 2007, 9 (02) :185-194
[8]   Design and fabrication of integrated passive valves and pumps for flexible polymer 3-dimensional microfluidic systems [J].
Jeon, NL ;
Chiu, DT ;
Wargo, CJ ;
Wu, HK ;
Choi, IS ;
Anderson, JR ;
Whitesides, GM .
BIOMEDICAL MICRODEVICES, 2002, 4 (02) :117-121
[9]   Fabrication of a peristaltic PDMS micropump [J].
Jeong, OC ;
Park, SW ;
Yang, SS ;
Pak, JJ .
SENSORS AND ACTUATORS A-PHYSICAL, 2005, 123-24 :453-458
[10]   A novel micromachined pump based on thick-film piezoelectric actuation [J].
Koch, M ;
Harris, N ;
Evans, AGR ;
White, NM ;
Brunnschweiler, A .
SENSORS AND ACTUATORS A-PHYSICAL, 1998, 70 (1-2) :98-103