Structure of air-water two-phase flow in helically coiled tubes

被引:69
|
作者
Murai, Y
Yoshikawa, S
Toda, S
Ishikawa, M
Yamamoto, F
机构
[1] Hokkaido Univ, Sch Engn, Div Energy & Environm Syst, Sapporo, Hokkaido 0608628, Japan
[2] Japan Nucl Cycle Dev Inst, Int Cooperat & Tech Dev Ctr, Tsuruga, Japan
[3] Kawasaki Plant Syst Ltd, Tokyo 1368588, Japan
[4] Univ Ryukyus, Dept Mech Syst Engn, Okinawa 9030213, Japan
[5] Univ Fukui, Sch English, Fiber Amen Engn Course, Fukui 9108507, Japan
关键词
D O I
10.1016/j.nucengdes.2005.04.011
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Air-water two-phase flow in helically coiled tubes is investigated experimentally to elucidate the effects of centrifugal acceleration on the flow regime map and the spatial and the temporal flow structure distribution. Three kinds of test tubes with 20 mm inner diameters including a straight tube are used to compare the turbulent flow structure. Superficial velocities up to 6 m/s are tested so that the centrifugal Froude number covers a range from 0 to 3. The interfacial structure is photographed from two directions by a high-speed video system with synchronized measurement of local pressure fluctuations. The results reveal that the flow transition line alters due to centrifugal force acting on the liquid phase in the tube. In particular, the bubbly flow regime is narrowed significantly. The pressure fluctuation amplitude gets large relatively to the average pressure loss as void fraction increases. The frequency spectra of the pressure fluctuation have plural peaks in the case of strong curvature, implying that the periodicity of slugging two-phase flow is collapsed by an internal secondary flow activated inside the liquid phase. Moreover, under large Froude number conditions, the substantial velocity of the gas phase that biases to the inner side of the helical coil is slower than the total superficial velocity because the liquid flow is allowed to pass through the outer side and so resembles a radial stratified flow. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:94 / 106
页数:13
相关论文
共 50 条
  • [11] Dryout quality prediction for boiling two-phase flow in vertical helically coiled tubes
    Niu, Xiaojuan
    Yuan, Huaijie
    Quan, Chen
    Zhao, Liang
    APPLIED THERMAL ENGINEERING, 2018, 128 : 982 - 992
  • [12] Two-phase flow model of refrigerants flowing through helically coiled capillary tubes
    Chingulpitak, Sukkarin
    Wongwises, Somchai
    APPLIED THERMAL ENGINEERING, 2010, 30 (14-15) : 1927 - 1936
  • [13] Flow patterns in two-phase air-water flow
    Sch. of Mech. and Prod. Engineering, Nanyang Technological University, Nanyang Avenue, Singapore 639798, Singapore
    Int Commun Heat Mass Transfer, 1 (111-118):
  • [14] Flow patterns in two-phase air-water flow
    Wong, TN
    Yau, YK
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1997, 24 (01) : 111 - 118
  • [15] CFD study of an air-water flow inside helically coiled pipes
    Colombo, Marco
    Cammi, Antonio
    Guedon, Gael Raymond
    Inzoli, Fabio
    Ricotti, Marco Enrico
    PROGRESS IN NUCLEAR ENERGY, 2015, 85 : 462 - 472
  • [16] A review on the two-phase pressure drop characteristics in helically coiled tubes
    Fsadni, Andrew Michael
    Whitty, Justin P. M.
    APPLIED THERMAL ENGINEERING, 2016, 103 : 616 - 638
  • [17] Some characteristics of air-water two-phase flow in small diameter vertical tubes
    Mishima, K
    Hibiki, T
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1996, 22 (04) : 703 - 712
  • [18] Air-water two-phase flow in pipe bends
    Hapanowicz, J
    Troniewski, L
    Witczak, S
    INZYNIERIA CHEMICZNA I PROCESOWA, 2001, 22 (02): : 219 - 237
  • [19] Modeling of air-water two-phase annular flow
    Ratkovich, Nicolas, 2016, Universidad Central de Venezuela (54):
  • [20] Characterization of horizontal air-water two-phase flow
    Kong, Ran
    Kim, Seungjin
    NUCLEAR ENGINEERING AND DESIGN, 2017, 312 : 266 - 276