Random Correction Method for Positron Emission Mammography Using Delayed Coincidence Data

被引:0
作者
Cao, Liji [1 ]
Bugalho, Ricardo [2 ]
Ortigao, Catarina [2 ]
Varela, Joao [2 ]
Peter, Joerg [1 ]
机构
[1] German Canc Res Ctr, Div Med Phys Radiol, Heidelberg, Germany
[2] LIP, Lisbon, Portugal
来源
2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC) | 2012年
关键词
MAXIMUM-LIKELIHOOD RECONSTRUCTION; CLEAR-PEM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A dedicated random correction algorithm is presented in this study for positron emission mammography (PEM) systems. PEM refers to a specified PET system that is optimized for breast imaging by its small FOV. Clinical imaging results from such systems, however, may be degraded by strong statistical noise caused from random coincidences, especially in the region that is near to the torso, due to the high amount of activity uptake outside the FOV, the low geometrical sensitivity of the detector elements near to the torso, and the large solid angle acceptance of random coincidence events. Because of the low statistics of detected coincidence events against the extremely high number of LORs, list-mode reconstruction algorithms are suggested for PEM systems. The conventional random correction methods cannot be directly implemented or can induce an even higher statistical noise. The correction method by single count rate requires a high hardware cost to record single events and needs an accurate calibration to reach a non-bias correction. The new random correction algorithm presented in this study can be implemented into list-mode reconstruction without single count acquisition. This algorithm estimates in a first step a smooth correction image with the delayed coincidences data. This correction image is then used to estimate the mean random coincidence rate for each detected event during the iterative list-mode reconstruction routine. The approach is tested on a ClearPEM system developed by the Crystal Clear Collaboration. Experimental data are acquired by two face-to-face detectors at four angular positions with a total acquisition time of 20 min for each breast. Results show that the proposed algorithm can largely suppress the statistical noise in the region near the torso.
引用
收藏
页码:2958 / 2962
页数:5
相关论文
共 11 条
  • [1] Long-term stability of the Clear-PEM detector modules
    Amaral, Pedro
    Bruyndonckx, Peter
    Carrico, Bruno
    Ferreira, Miguel
    Luyten, Joan
    Moura, Rui
    Ortigao, Catarina
    Rodrigues, Pedro
    Da Silva, Jose C.
    Trindade, Andreia
    Varela, Joao
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) : 488 - 492
  • [2] Brasse D, 2005, J NUCL MED, V46, P859
  • [3] Cao LJ, 2011, IEEE NUCL SCI CONF R, P4171, DOI 10.1109/NSSMIC.2011.6153798
  • [4] List-mode maximum-likelihood reconstruction applied to positron emission mammography (PEM) with irregular sampling
    Huesman, RH
    Klein, GJ
    Moses, WW
    Qi, JY
    Reutter, BW
    Virador, PRG
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 532 - 537
  • [5] Enhanced 3D PET OSEM reconstruction using inter-update Metz filtering
    Jacobson, M
    Levkovitz, R
    Ben-Tal, A
    Thielemans, K
    Spinks, T
    Belluzzo, D
    Pagani, E
    Bettinardi, V
    Gilardi, MC
    Zverovich, A
    Mitra, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08) : 2417 - 2439
  • [6] Clear-PEM, a dedicated PET camera for mammography
    Lecoq, P
    Varela, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 486 (1-2) : 1 - 6
  • [7] Liow J., 1999, PHYS MED BIOL, V39, P735
  • [8] The ClearPEM breast imaging scanner
    Neves, Jorge A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 628 (01) : 444 - 447
  • [9] The positron emission mammography/tomography breast imaging and biopsy system (PEM/PET): design, construction and phantom-based measurements
    Raylman, Raymond R.
    Majewski, Stan
    Smith, Mark F.
    Proffitt, James
    Hammond, William
    Srinivasan, Amarnath
    McKisson, John
    Popov, Vladimir
    Weisenberger, Andrew
    Judy, Clifford O.
    Kross, Brian
    Ramasubramanian, Srikanth
    Banta, Larry E.
    Kinahan, Paul E.
    Champley, Kyle
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (03) : 637 - 653
  • [10] POSITRON EMISSION MAMMOGRAPHY (PEM) - A PROMISING TECHNIQUE FOR DETECTING BREAST-CANCER
    THOMPSON, CJ
    MURTHY, K
    PICARD, Y
    WEINBERG, IN
    MAKO, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1012 - 1017